(Refer to page 10 about the contact protection box.) 12.5 12.5 2.7 3.4 Most sensitive position Most sensitive position 12 Solid State Switches/Direct Mount Type D-Y59 , D-Y69 , D-Y7P(V) A B A B Auto Switches Specifications Grommet D-Y5, D-Y6, D-Y7P, D-Y7PV (with indicator light) D-Y59A Perpendicular D-Y69B D-Y69A D-Y7P Perpendicular D-Y59B Perpendicular D-Y7PV Auto switch part no.
D-A73 D-A80 D-A79W D-F7NTL Bore size A B A B 10 13.5 18 24 A B 7 10.5 15 21 A B 15 18.5 23 29 32 40 9.5 13 17.5 23.5 Note ) Adjust the auto switch after confirming the operating conditions in the actual setting.
state switch Relay, PLC 12 V Yes Yes No Grommet 24 V IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 12 V 3-wire (NPN equivalent) A96 A96V 5 V 24 V Grommet A93 A90 A93V A90V Relay, PLC 100 V 2-wire 12 V IC circuit 100 V or less Solid state auto switches marked with are produced upon receipt of order.
12 V 12 V Relay, PLC Yes Yes Grommet 24 V IC circuit 5 V,12 V Diagnostic indication (2-color indication) 12 V IC circuit A96V A96 5 V 12 V Grommet A93V A90V A93 A90 100 V Relay, PLC 2-wire 24 V IC circuit 100 V or less No Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with
() -27-67 NPN2 PNP2 -43 NPN PNP NPN PNP NPN PNP DC(+) -27 27 27 27 NPN 2 Max.30 V80 mA 1 V OUT1(NPN) DC12 24 V OUT2(NPN) DC(-) -43 43 43 43 NPN 1 + PNP 1 Max.30 V(NPN)80 mA 1 V NPN PNP DC(+) OUT1(NPN) DC12 24 V OUT2(PNP) DC(-) DC(+) OUT1(PNP) -65 65 65 65 PNP 1 Max.80 mA DC12 24 V N.C.
Inset the signal cable through the hole and fit the nipple A, nipple B and lock nut. Then fit the cap A, cap B and rubber bushing. Recommended cable diameter: 6 to 13 mm Signal cable entry For option B Signal cable entry Lock nut Nipple A Rubber bush Nipple B Cap B Cap A Fig. 3-9 Mounting to the cable gland Fit the nipple A and nipple B closely until it clicks.
4 Exhaust port 76 P Standard ZL212 40 V ZA 54 125 Label ZX 188 61 ZR P Port exhaust ZL212P ZM V ZMA Exhaust port (EXH.)
Description B VNH1 VNH2 VNH3 VNH4 VNH1-16 VNH2-16 VNH3-16 VNH4-16 Bracket (with bolt and washer) 4.2-30 VNH Specifications 3 port valve 2 port valve A B A B VNH311 20A A B VNH411 25A A B VNH113 10A A B VNH213 15A A B VNH313 20A A B VNH413 25A A B VNH133 10A A B VNH233 15A A B VNH333 20A A B VNH433 25A A B VNH111 10A VNH211 15A Model Operating fluid pressure Fluid Operation 0 to 7.0MPa 0 to
x 103 M Yaw moment M3 = m x g x (L + A) x 103 M Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYP15 CYP32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m : Load mass [kg] L : Distance to load center of gravity [mm] A, B : Distance to guide shaft [mm] g : Gravitational acceleration [9.8m/s] M2 M1 M3 m x g m x g Guide shaft mounting surface m x g Guide central axis Cylinder
x 103 M Yaw moment M3 = m x g x (L + A) x 103 M Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYP15 CYP32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m : Load mass [kg] L : Distance to load center of gravity [mm] A, B : Distance to guide shaft [mm] g : Gravitational acceleration [9.8m/s] M2 M1 M3 m x g m x g Guide shaft mounting surface m x g Guide central axis Cylinder
A C F U U M V E A V L Heater (Option) (Maintenance space) Auto switch (Option) B J XLA XL H XLQ XLQ G XM XY DXSA A XVD XGT CYV A (mm) Model A 120 133 178 190 B 38 48 66 79 C 1 1 2 2 D 12 11 11 E 30 40 55 75 F 17 26 41 52 G 40 39 63 68 H 87 91 129 142 J XLAQ-16 XLAQ-25 XLAQ-40 XLAQ-50 40 50 65 70 Note) The heater (Option) is not available with XLAQ-16. 471 Aluminum One-touch Connection and
(Refer to page 5 for detailed specifications of the contact protection boxes.) 6.2 5.7 3.4 12.5 Most sensitive position 8 Solid State Auto Switches/Direct Mount Type D-Y59 /D-Y69 /D-Y7P (V) A B A B Auto Switch Specifications D-Y5, D-Y6, D-Y7P, D-Y7PV (with indicator light) D-Y7PV D-Y59B D-Y59A D-Y69A D-Y7P D-Y69B Auto switch part no.
12 V 5V, 12 V 12 V 5 V, 12 V 12 V IC circuit Solid state switch Reed switch IC circuit Relay, PLC Diagnosis (2-color indication) 24 V Grommet Yes IC circuit Water resistant (2-color indication) M9PAV M9BAV A96 A93 A90 A96V A93V A90V IC circuit IC circuit 5 V 12 V 3-wire (NPN equivalent) Yes Grommet 100 V Relay, PLC 2-wire 24 V No 5 V,12 V 100 V or less Water resistant type auto switches
N06 NPT3/4 5/16(inch) N04 2xNPT1/2 6) 5 DC24V *1G JIS B0202 ISO1603 ISO1179 8) Z 7 L L 0.3(m) 11) A NPN LO B PNP M M 0.3(m) MO 12) 9) M SI (kPa) D P (:psi) E 10) 14 GN (G) B G *7ZL212 27mm ZL212 (2 /1 , 4 ) E (2 ) F (2 ) V (1 ) 13 G 2m) W (2m) 5 No.ZL3-OM00801-A 2. 2.1 (1/P) (2/V) ZL3 ZL6 (3/E) // / (G) (2/V) 2.2 ZL6 1 ZL6 (ZL6-SC1-A) 2), 6 No.ZL3-OM00801-A 3. 3.1
(Looked by double solenoid valve) (Looked by double solenoid valve) SOL. location B (*) B (*) B B A B A B A B A B A A A A B A B A SOL. location VQC 3 position 3 position Double Double Double Double SI unit Single Single SI unit Single Single SQ Stations 1 2 3 4 5 Stations 1 2 3 4 5 VQ0 The places of asterisk are not used.
A B C D Maximum Speeds for Each Transfer Load Unit (mm/s) Transfer load (kg) 15 20 25 30 1000 1000 930 740 600 500 Model Note LJ1H202PC-500LJ1H202PC-600LJ1H202PC-700LJ1H202PC-800LJ1H202PC-900LJ1H202PC-1000700 700 600 600 500 500 500 500 500 500 500 500 500 500 500 500 500 500 Power supply: 100/110(V)AC 10% Compatible controller: LC1-1B2H1Power supply: 200/220(V)AC 10% Compatible controller
V MC1 THR TB1,2 SWL PRR PRS1 PRS2 PRS3 PLC HM GFCI EDV IDF100F150F-W 6 6 IDX-OM-Z004 6 6.5 Y Y ,, IDF100F150F-W 6 7 IDX-OM-Z004 6 6.6 () (1) ADH-E400 V 1 -(2) 1 1 ) 1 2 ) Y92S-36/CR2477/ () 1 B 20,000 (6 ) 1 B 20,000 (6 ) 1 B 20,000 (6 ) 1 B 20,000 (6 ) 1 A 20,000 (6 ) 1 A 20,000 (6 ) 1 A 20,000 (6 ) 1 A 20,000 (6 ) 12 /JEMA 300 A B IDF100F150F-W 6 8