AS: AS, Body Size: 2 (1/8, 1/4 Basis), Style: 2 (Elbow), Control Method: 1 (Meter-in), Thread: N (NPT), Port Size: 01 (1/8), Applicable Tube OD: 03 (5/32"), Option: None, Lock Nut: J (Round)
Body Size: 100 (M5 Basis), Applicable Tube OD: 03 (5/32"), Lock Nut: J (Round)
Model: ASR (Pressure Valve), Size: 6 (1/2 Standard), Port Size: 03 (3/8), Applicable Tubing O.D.: 12 (ø12mm), Option: Variable set pressure type (0.1 to 0.3 MPa), Lock Nut: J (Round)
Model: 33, Orifice: 4 (4mm), Style: 0 (N.C., Single Unit), Option: J (Stainless Steel, Seals: EPDM, Class B), Suffix: Standard, Port Size: 03 (3/8), Thread: N (NPT), Voltage: 6 (12VDC), Electrical Entry: D (DIN Terminal), Surge Suppressor: Non, Rectifier: None (for DC or AC Class H Coil)
Model: 33, Orifice: 3 (3mm), Style: 4 (COM, Single Unit), Option: C37, Seals: NBR, Class B, Suffix: Standard, Port Size: 03 (3/8), Thread: F (G), Voltage: J (230VAC 50/60HZ), Electrical Entry: D (DIN Terminal), Surge Suppressor: Non, Rectifier: R (AC Class B Coil w/Full-wave Rectifier)
Model: 32, Orifice: 3 (3mm), Style: 0 (N.C., Single Unit), Option: J (Stainless Steel, Seals: EPDM, Class B), Suffix: Z (Oil-free), Port Size: 03 (3/8), Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Electrical Entry: D (DIN Terminal), Surge Suppressor: Non, Rectifier: R (AC Class B Coil w/Full-wave Rectifier), Bracket: B (Bracket)
Model: 33, Orifice: 4 (4mm), Style: 4 (COM, Single Unit), Option: J (Stainless Steel, Seals: EPDM, Class B), Suffix: Z (Oil-free), Port Size: 03 (3/8), Thread: N (NPT), Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Surge Suppressor: Non, Rectifier: None (for DC or AC Class H Coil)
Model: 32, Orifice: 3 (3mm), Style: 0 (N.C., Single Unit), Option: J (Stainless Steel, Seals: EPDM, Class B), Suffix: Standard, Port Size: 03 (3/8), Thread: N (NPT), Voltage: 5 (24VDC), Electrical Entry: G (Grommet), Surge Suppressor: Non, Rectifier: None (for DC or AC Class H Coil)
Model: 32, Orifice: 4 (4mm), Style: 4 (COM, Single Unit), Option: J (Stainless Steel, Seals: EPDM, Class B), Suffix: Standard, Port Size: 03 (3/8), Thread: Rc, Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Surge Suppressor: Z (w/Light and Surge Voltage Suppressor), Rectifier: None (for DC or AC Class H Coil), Bracket: B (Bracket)
Model: 33, Orifice: 4 (4mm), Style: 0 (N.C., Single Unit), Option: J (Stainless Steel, Seals: EPDM, Class B), Suffix: Standard, Port Size: 03 (3/8), Thread: N (NPT), Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Surge Suppressor: Non, Rectifier: None (for DC or AC Class H Coil)
Model: 32, Orifice: 4 (4mm), Style: 0 (N.C., Single Unit), Option: J (Stainless Steel, Seals: EPDM, Class B), Suffix: Standard, Port Size: 03 (3/8), Thread: N (NPT), Voltage: 3 (110VAC 50/60HZ), Electrical Entry: C (Conduit), Surge Suppressor: Non, Rectifier: R (AC Class B Coil w/Full-wave Rectifier), Bracket: B (Bracket)
Model: 33, Orifice: 4 (4mm), Style: 0 (N.C., Single Unit), Option: J (Stainless Steel, Seals: EPDM, Class B), Suffix: Z (Oil-free), Port Size: 03 (3/8), Thread: N (NPT), Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Surge Suppressor: L (w/Light), Rectifier: None (for DC or AC Class H Coil), Bracket: B (Bracket)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: B (OUT1: PNP; OUT2: PNP), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: J (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: B (OUT1: PNP; OUT2: PNP), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: J (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F), Bracket: R (Bracket)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: C (OUT1: NPN; OUT2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: J (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: E (OUT1: PNP; OUT2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: J (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: F (OUT1: PNP; OUT2: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: J (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F), Bracket: R (Bracket)
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: D (OUT1: NPN; OUT2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: J (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F), Bracket: R (Bracket), Calibration Certificate: A (Calibration
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: D (OUT1: NPN; OUT2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: J (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F), Bracket: R (Bracket), Calibration Certificate: A (Calibration
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 03 (3/8), Output Specification: C (OUT1: NPN; OUT2: Analog 1 to 5V), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: J (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F), Bracket: R (Bracket)