SMC Corporation of America
Elite Part Number Search
Search Results "22-CDM2RA20-25Z"

Conductor area 0.15 mm2 (AWG26) Model M5 01 N01 Port size M5 x 0.8 R1/8 NPT1/8 Insulator O.D. 1.0 mm Color Brown, Blue, Black (3-core) Sheath Finished O.D. 3.4 Sensor pressure receiving area Silicon Piping port (Common) PBT, CB156, Heat-resistant PPS, O-ring: HNBR Piping port C3604 (Electroless nickel plating), Stainless steel 304, NBR Materials of parts in contact with fluid Weight Body 22

PA02] 0 0 Select a regenerative option. 00: Regenerative option is not used. 00: 100 W 0.2 kW 7 kW 11 kW 22 kW 01: FR-BU2FR-RC FR-CV 02: MR-RB032 03: MR-RB12 04: MR-RB32 05: MR-RB30 06: MR-RB50 () 08: MR-RB31 09: MR-RB51 () 0B: MR-RB3N 0C: MR-RB5N ( ) FA: 11 kW 22 kW UP For drivers of LECSN-T5, do not use a regenerative resistor.

. -22- Recommended Parameter Values [LEY] LEY25/ LEY25D/ LEY32/ LEY32D/ LEYG25 LEYG25D LEYG32 LEYG32D Series Lead symbol A B C A B C A B C A B C Lead 12 6 3 12 6 3 20 10 5 16 8 4 Parameter *1,*2 Para.

. / (420) 5-414 24611 NORWAY / (47) 67 12 90 20 DENMARK / (45) 70 25 29 00 POLAND / (48) 22-548 50 85 FINLAND / (358) 9-859 580 PORTUGAL / (351) 2 610 89 22 FRANCE / (33) 1-64 76 1000 SPAIN / (34) 945-18 4100 GERMANY / (49) 6103 4020 SWEDEN / (46) 8-603 0700 GREECE / (30) 1342 6076 SWITZERLAND / (41) 52-396 3131 HUNGARY / (36) 1-371 1343 TURKEY / (90) 212 221 1512 IRELAND / (353) 1-403 9000

ZQ-OM01301-A Revision history A P.22 Change of the spare part numbers for the solenoid valve P.24 Change of the spare part numbers for the V port fitting P.25 Change of the spare part numbers for the Washer assembly P.27 P.28 Added items to 8.

(Allowable inclination difference in the vertical direction is 5) 3) For IDFB60, mount male elbow (width across flats: 22) to the drain outlet port (width across flats: 27). For IDFB70, IDFB80 and IDFB90, mount male connector (width across flats: 22) to the drain outlet port (width across flats: 22) and mount the drain tube.

P20 to 21 P23 to 24 P26 to 27 Note) Fluorine grease is recommended when applying additional grease. -22- 10. How to Replace the Components Warning Before replacement, make sure that no pressure remains in the equipment.

P20 to 21 P23 to 24 P26 to 27 Note) Fluorine grease is recommended when applying additional grease. -22- 10. How to Replace the Components Warning Before replacement, make sure that no pressure remains in the equipment.

P20 to 21 P23 to 24 P26 to 27 Note) Fluorine grease is recommended when applying additional grease. -22- 10. How to Replace the Components Warning Before replacement, make sure that no pressure remains in the equipment.

Trouble Shooting 22 10. How to Replace the Components 23-26 10-1. Bowl Assembly Replacement 23-24 10-2. Element Replacement 25-26 11. Disassembly Drawing 27 12. Dimensions 28 -1- Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.

Para maiores informaes, consulte o site da ANATEL www.anatel.gov.br ANATEL06513-22-14800 Made in Japan Incorpora produto homologado pela Anatel sob nmero 06513-22-14800 . (This telecommunication equipment conforms to the technical standards or requirements of NBTC.) -7No.EX-OMZ0016-C Precautions for Handling Follow the instructions given below for selecting and handling.

24.5 X 15.5 15.5 15.5 Fitting size 4, 5/32 6 1/4 Y 21.5 22 24.5 X 10.5 10.5 10.5 Fitting size 4, 5/32 6 1/4 10.5 5.5 X X Y Y 236 Compact Manifold Regulator/Common Supply Type Series ARM11A Replacement Procedure is P.453 Construction Actuators Modular F.R.L.

19 41 562 -X Switch groove (Both-side type) 90 12 9 11 9 20 105 MHKL2-12S Normally open Normally closed Without magnet MRHQ 16 17 14 14.6 28.6 165 MHKL2-16S EPDM seal/Fluorine grease 20 32 18 16 34 314 MHKL2-20S Fluorine grease MA 25 53 22 19 41 565 MHKL2-25S Finger: Side tapped mounting 12 11 11 9 20 105 MHKL2-12C DFinger: Through-hole mounting 16 22 14 14.6 28.6 166 MHKL2-16C Dust cover

Use the series AKM check valve to avoid such possibility. 57 53 30 81 22 Notes) in model numbers indicates a thread type. No indication is necessary for Rc; however, indicate N for NPT, and F for G. Separate interfaces are required for modular unit.

Bracket 5 1/4, 3/8, 1/2 AF40 Float type auto drain 3/4 AF40-06 3/4, 1 AF50 1 AF60 Pages 23 through 27 Mist separator Series AFM AFM20 1/8, 1/4 Bracket AFM30 1/4, 3/8 0.3 Float type auto drain AFM40 1/4, 3/8, 1/2 AFM40-06 3/4 Pages 29 through 31 Micro-mist separator Series AFD AFD20 1/8, 1/4 Bracket AFD30 1/4, 3/8 0.01 Float type auto drain AFD40 1/4, 3/8, 1/2 3/4 AFD40-06 Pages 32 through 34 22

18.0 l3i ) (37) z.2a (58) 7.20 (143) 7 6 8 o95) 2.05 (52) 11.2) 2 6 0 (66) S T o e 7.52 1 9 1 ) 799 1203t L3a 135) l85l 2.52 (64) 0.79 (20) 1.57 140) 0.39 00) 0.67 (171 M8x1.25 0.28 t7) 1 5 7 M 1 8 x 1 . 5 '|.22 (31) 0.63 (16) 3.65 {98) 1.91 (23) 25.0 l3i ) 1.89 ga) 2.24 (58) T.-t2 (r96j 8.35 (212) 2.O5 (vJ 1 1 2 ) ?.

18 36 7 28.5 M6 x 1.0 10 50 28 22 44 8 33.5 M8 x 1.25 14 63 30 22 44 8 33.5 M10 x 1.5 14 Rod end nut L1 The clevis pin and snap ring are packed with the clevis.

Model Width 22 3.3 ftlbf (4.5 Nm) 41.5 MXP12-15 2.7 times 18.5 1.22 ftlbf (1.65 Nm) 68 96 Note1) MXF12-20 All dimensions in mm. Note 1) At fully stroke extended. MXPJ6 Mounting on equipment is possible from top side (through hole) and bottom side body tapped.

(Unit : lbf) Bore size (mm) Rod diameter (mm) Piston area (in 2) Operating pressure (PSI) Operating direction 22 40 60 80 100 3.43 6.23 9.35 12.5 15.6 0.156 OUT 4 8 Precautions 2.57 4.67 7.01 9.35 11.7 0.117 IN OUT 7.71 14.0 21.0 28.0 35.1 0.351 6 12 (1) The table is supported by precision bearings.