SMC Corporation of America
Elite Part Number Search
Search Results "ZK2P00K5NL2A-06-BK"

System: P (Vacuum Pump System, Single Unit), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor, 0 to -101, Analog Output 1 to 5 V), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting), Bracket: B [One Bracket for Mounting Single Unit

Body/Exhaust Type: G (Single Unit - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), IO-Link compatible vacuum pressure switch: 5 (-100 to 100 kPa, w/ Unit Selection, w/Energy Saving), Connector: L3 (without connector), Vacuum, V Port: 07 (ø1/4 One-touch Fitting, Inch), Bracket: B [With One

Vacuum Ejector, ZK2, VACUUM EJECTOR, 99.00000 lb

Vacuum Ejector, ZK2, VACUUM EJECTOR, 99.00000 lb

Vacuum Ejector, ZK2, VACUUM EJECTOR, 99.00000 lb

Body/Exhaust Type: B (Single Unit - Port Exhaust), Nominal Nozzle Size: 15 (ø1.5), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: K (Digital Pressure Switch for Vacuum with Energy Saving Function / 100 to -100 kPa / NPN 1 Output), Connector: W (With Lead Wire for Switch with Energy Saving Function), Vacuum, V Port: 07 [ø1/4 One-touch Fitting (Inch

Body/Exhaust Type: G (Single Unit - High-noise Reduction Silencer Exhaust), Nominal Nozzle Size: 10 (ø1.0), Supply Valve and Release Valve: K (N.C. / N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: T (Pressure Sensor / -100 to 100 kPa / Analogue Output 1 to 5 V), Connector: L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor], Vacuum

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø1.0 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Inch

System/Body: Ejector System, Single Unit, Port Exhaust, Nozzle Size: Ejector System, ø1.2 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum w/Energy Saving Function, 100 to -100, NPN 1 Output, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: w/Lead Wire for Switch

System/Body: Ejector System, Single Unit, Port Exhaust, Nozzle Size: Ejector System, ø1.2 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum w/Energy Saving Function, 100 to -100, PNP 1 Output, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: w/Lead Wire for Switch

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø1.0 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum w/Energy Saving Function, 100 to -100, PNP 1 Output, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: w/Lead Wire for Switch

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø1.5 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs, SI Unit Only, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Metric Size, ø8

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø1.2 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 12 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Inch Size

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø1.5 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Metric

System/Body: Ejector System, Single Unit, Port Exhaust, Nozzle Size: Ejector System, ø1.5 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: w/o Pressure Sensor, Digital Pressure Switch for Vacuum, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Inch Size, ø1/4" One-touch Fitting, Optional

System/Body: Vacuum Pump System, Single Unit, Nozzle Size: Vacuum Pump System, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, NPN 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Inch Size, ø1/4" One-touch Fitting, Optional

System/Body: Vacuum Pump System, Single Unit, Nozzle Size: Vacuum Pump System, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Pressure Sensor, 0 to -101, Analog Output 1 to 5 V, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Inch Size, ø1/4" One-touch Fitting, Optional Specs. 1: B [One Bracket for Mounting

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø0.7 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: w/o Pressure Sensor, Digital Pressure Switch for Vacuum, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Inch Size, ø1/4" One-touch Fitting,

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø1.5 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, Unit Selection Function, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Metric

System/Body: Ejector System, Single Unit, Silencer Exhaust, Nozzle Size: Ejector System, ø1.5 Nominal Nozzle Size, Valves: Supply Valve; N.C., Release Valve; N.C., Rated Voltage: 24 VDC, Sensor/Switch for Vacuum Specs.: w/o Pressure Sensor, Digital Pressure Switch for Vacuum, Valves/Switch for Vacuum Conn. Specs.: L-type Plug Connector, Vacuum, V Port: Inch Size, ø1/4" One-touch Fitting,