switch 12 V 5 V, 12 V 12 V 5 V, 12 V 12 V 2-wire J79C Connector M9NWV M9PWV M9BWV M9NAV M9PAV M9BAV 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 4-wire Relay, PLC IC circuit Diagnostic indication (2-color indication) 24 V Yes Grommet Water resistance (2-color indication) IC circuit F79F IC circuit 5 V,12 V With diagnostic output (2-color indication) 3-wire (NPN
) Port size Bore size (mm) GA H J JA A B A' C CA CB D E GB 20 25 32 29 32.5 35 19 23 27 16 20 24 12 15 19 26 32 40 42 50 62 20 25 31 22 25 31 9 10 11 27 22.5 25 14 18 22 12 15.5 19.5 8 10 12 M5 x 0.8 M5 x 0.8 Rc 1/8 Bore size (mm) NN T S Z K KA L MM P Q R Standard strokes 20 25 32 M5 x 0.8 with depth 8 M5 x 0.8 with depth 8 M6 x 1.0 with depth 9 9.3 with depth 8 9.3 with depth 9 11 with depth
10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 1/4" 6 12 3/8" 10 20 5/8" 15 40 3/4" 20 60 1" 25 80 32 1-1/4" 80 1-1/2" 40 80 2" 50 80 2-1/2" 63 80 Note) The longer the stroke, the larger the amount of deflection in a cylinder tube.
(mm) 02 04 06 08 10 13 16 20 25 32 40 50 2 4 6 8 10 13 16 20 25 32 40 50 Pad type 02 04 06 08 10 13 16 20 25 32 40 50 2 4 6 8 10 13 16 20 25 32 40 50 Pressure gauge position Thread dia.
24 30 to to B With lock A 12 16 20 1200 1200 B 6 8 10 *Refet to Applicable Stroke Table.
-20 MXP12-15 MXP12-25 MXP16-20 MXP16-30 Additional mass of magnet and rail 10 10 8 12 13 20 17 23 20 23 Exclusive body is to be used for the one with shock absorber.
229 34 227 7.1 8.5 20 8 36 13 229 34 227 8.6 10.5 25 8 36 15.5 229 34 227 10.6 P (Port thread size) P1 (Lock release port thread size) Nil G1/4 TN TF Nil TF TN Rc1/4 NPT1/4 Rc1/8 G1/8 NPT1/8 12 Series CKQ/CLKQ Pin Clamp Cylinder How to Mount the Auto Awitches (1) For D-A7, D-A80, D-F7 and D-J79 models Slide a mounting nut into the auto switch groove and align it to where the auto switch
Flow range: 0.5 to 4 L/min (symbol 04) Pressure: 0.3 MPa Piping bore size: 12 Flow range: 2 to 16 L/min (symbol 20) Pressure: 0.3 MPa Piping bore size: 12 Flow range: 5 to 40 L/min (symbol 40) Pressure: 0.3 MPa Piping bore size: 16 -60No.PF-OMW0004-B Analogue output Analogue output (Flow) (PF3W704/720/740) A B C Voltage output 1 V 1.5 V 5 V Current output 4 mA 6 mA 20 mA Rated flow [L/min
W 5 156 168 Dimensions [mm] LA LB LC 99 LD 1.6 Model LEC-MR-RB-032 LEC-MR-RB-12 30 40 119 169 149 2 LD LC 6 6 (20) LB 104 Incremental Type Series LECSA Absolute Type Series LECSB Options MR Configurator (setup software Japanese version) LEC MR SETUP221 MRZJW3-SETUP221 manufactured by Mitsubishi Electric.
B C D H SNKJ-016B SNLJ-016B SN-020B SN-032B NTJ-010A NTJ-015A NT-02 NT-03 19.6 M12 x 1 4 8.1 M4 x 0.7 3.2 6, 10 17 6, 10 7 21.9 M14 x 1 5 9.2 M5 x 0.8 4 16 19 16 8 30 M20 x 1.5 8 15 M8 x 1.25 5 20 26 20 13 37 M26 x 1.5 8 19.6 M10 x 1.25 6 25 32 25 17 T-bracket 4-TC TH 7 +0.2 0 TU -0.1 -0.3 TN TK TX TV 12 TD H10 TT TY TW Part no.
57 5 7.6 29 11.4 5.2 16.4 27 10 23 16 37.8 23 6 18 12 0.02 0.02 0.05 112211221122MHZ2-16D 5 15 67.3 8 11 38 16 6.5 23.6 30 13 30.6 24 42.5 24.5 7.5 22 15 0.02 0.02 0.05 MHZ2-20D 8 18 84.8 10 16.8 50 18.6 7.5 27.6 35 15 42 30 52.8 29 9.5 32 20 0.02 0.02 0.05 MHZ2-25D 102.7 63 33.6 52 63.6 11 25 10 12 22 36.5 36 30 40 22 21.8 10 20 0.02 0.02 0.05 U V W X Y Z AA AB AC AD AE AF AG AH AJ AK Model
(mm) Applicable cylinder bore size (mm) 4 6 8 10 12 AS-FPG AS-FPQ Clean performance Resin: PP Metal: Brass (electroless nickel plated) Resin: PP Metal: Stainless steel (SUS304) M5 x 0.8 6, 10, 16, 20 AS121FP-M5 R 1/8 20, 25, 32 AS221FP-01 R 1/4 20, 25, 32, 40 AS221FP-02 R 3/8 40, 50, 63 AS321FP-03 10-AS-F 10-AS-FG R 1/2 63, 80, 100 AS421FP-04 Resin: PBT, POM Metal: Brass (electroless nickel
12 14 16 18 20 30 Hz Discharge time (s) Discharge time (s) 1 Hz 30 Hz 1 Hz 0 500 1,000 1,500 2,000 0 500 1,000 1,500 2,000 Installation distance (mm) Installation distance (mm) Supply pressure: 0.3 MPa (17.6 L/min [ANR] per cartridge) Supply pressure: 0.3 MPa (8.6 L/min [ANR] per cartridge) 12 12 10 10 Discharge time (s) Discharge time (s) 8 8 6 6 30 Hz 1 Hz 30 Hz 1 Hz 4 4 2 2 0 0 0 500
CN4I/O . 19 (1) . 19 (2) . 20 5.4 CN5: . 20 6.
Enable 1 Disable -10..10 V -5..5 V -20..20 mA 0..10 V 2 -10..10 V 0..5 V 1..5 V 0..20 mA 4..20 mA Offset binary 3 PLC Sign & Magnitude 2s complement 2 None 2AVG 2 4 4AVG 4 8AVG 8 Enable 0.5 5 Disable Enable 0.5 6 Disable Enable 7 Disable Enable 8 Disable 1 -49No.EX-OMS0026CN -10..+10 V -10.50+10.45 V -10.45+10.50 V -5..+5 V -5.25+5.22 V -5.22+5.25 V -20..+20 mA
7 7 7 8 ZP10B ZPT2-7A-X2 ZP 13 B ZPG13B-7A-X2 7 8 8 8 ZP13B ZP 16 B ZPG16B-7A-X2 8 8 8 9 ZP16B ZP 20 B ZPG20B-7A-X2 11 11 11 13 ZP20B ZPT3-7A-X2 ZP 25 B ZPG25B-7A-X2 11 12 12 14 ZP25B ZP 32 B ZPG32B-7A-X2 14 15 15 18 ZP32B ZP 20 UT ZPG20UT-7A-X2 4 4 4 4 ZPT1-A6 ZP2-20UT ZP 16 J ZPG16J-7A-X2 8 8 8 9 ZPT2-7A-X2 ZP2-16J ZP B25 J ZPGB25J-7A-X2 14 15 15 18 ZP2-B25J ZPT3-7A-X2 ZP B30 J
H C37 3/4 20 J Stainless steel D 200 VAC E 230 VAC 6 25A N.C.
N-04 N-06 L-04 L-06 S-04 S-06 LL-04 LL-06 4 6 N-08 8 N-10 10 N-12 12 4 6 L-08 8 L-10 10 L-12 12 4 6 S-08 8 S-10 10 S-12 12 4 6 LL-08 8 LL-10 10 LL-12 12 Precautions Be sure to read before handling.
selectable) Yes Short circuit protection 20 0.1 2 x M3 x 0.5 Thread depth 4 30 25 8 9.5 Lead wire with connector M5 x 0.8 20 0.1 10 30 R 1/8 1.5 Width across flats 12 Digital Pressure Switch ZSE30A Assembly 13 P601010 q w e Included Parts No. 1 2 3 Description Digital pressure switch Gauge nut O-ring Symbol 1 2 3 4 Digital pressure switch part no.
Model Power source Frequency (Hz) 50 25 12 60 20 8 50 45 20 60 40 15 50 60 25 60 50 20 AC VXD21 DC AC VXD22 DC AC VXD23 DC Operating Fluid and Ambient Temperature Operating fluid temperature (C ) High temperature oil (3) Ambient temperature (C ) Temperature conditions Power source Water (Standard) Air (Standard) Oil (Standard) (D, E, N, P) High temperature water (3) (D, N) 99(4) 100(4) AC