Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 1 (Meter-in), Indicator Direction: None (0°), Thread: R, Port Size: M5 (M5 x 0.8), Width Across Flats: 9mm, Tubing: 02 (ø2)
Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 0 (Meter-out), Indicator Direction: None (0°), Thread: R, Port Size: M5 (M5 x 0.8), Width Across Flats: 9mm, Tubing: 02 (ø2)
Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 0 (Meter-out), Indicator Direction: 1 (180°), Thread: R, Port Size: M5 (M5 x 0.8), Width Across Flats: 9mm, Tubing: 02 (ø2)
Speed controller with one-touch fittings , Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2 , Maximum operating pressure 1MPa, Meter in or meter out control , Port sizes: M3, M5, U10/32, 01, 02, 03, 04 , Various tube O.D. in both metric and inch, SPEED CONTROL W/FITTING, AIRLINE EQUIPMENT, FLOW CONTROL W/FITTING, AB, AS***F M5 STANDARD (PT), 0.05322 lb
A 24 M5 thread, depth 8 With or without insert depending on base material. 32 A' Coding stud M5 x 10 DIN913-45H 12 2 8 M5 Drive flange face G1/4 DIN/ISO228/1 19.5 5.5 Solenoid valve flange face O-ring 16 x 2 1.5 IP 3 IW 1301 AW The solenoid valve can be attached with 2 mounting bolts.
Speed controller with one-touch fittings , Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2 , Maximum operating pressure 1MPa, Meter in or meter out control , Port sizes: M3, M5, U10/32, 01, 02, 03, 04 , Various tube O.D. in both metric and inch, FLOW CONTROL, AIRLINE EQUIPMENT, FLOW CONTROL W/FITTING, AB, AS***F M5 STANDARD (PT), .56830 lb
Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 0 (Meter-out), Control Range: FSM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: M5 (M5 x 0.8), Width Across Flats [H]: E (8mm), Tube Size: 02 (ø2)
close proximity with each other either horizontally or vertically Plug connection ower supply output connection 30 e-Con connector Analog output or auto shift input 2 outputs + Sensor connection M5 female thread, through type (with mounting holes) M3 M5 female thread, through type M5 6 reducer 4 reducer R1/8,NPT1/8 Applications Manifolding is possible.
AU200/300 Effective thread depth 6.5 4-M5 x 0.8 AU200, 300 Float type auto-drain Port size H G F E D C B A Model Port size 1 4 / 3 8 AU200 / 50 70 61 30 40.5 31.5 164 165 AU300 50 70 61 30 40.5 31.5 188.5 165 14-3-12
B 0 Normally Closed/Single unit Electrical option Nil None Port size S With surge voltage suppressor L With indicator light 02 03 04 Rc 1/4 Rc 3/8 Rc 1/2 With light/surge voltage suppressor Z Refer to the table (1) given below for availability.
I ~J' 20 24.5 zs -~ -eli Bracket View A Panel Mount Type Side dimensions for 418 panel mount type 0 40 21.2 , 6 8.5 36.0-5 >, D 0 . 1,16o;~1 ~ \ z 5-22-0 1 ZS-22-02 Thickness of the panel is 1 to 3.2mm. Panel mount adaptor A Panel mount adaptor B SMC CORPORATION 1-16-4 Shrmbashi. Mlnalo-kv.
size 20 30 40 50 60 AFF Nominal filtration rating: 1 m V V V V V Water droplet removal ratio: 99% AM Nominal filtration rating: 0.1 m V V V V V Oil mist concentration on the outlet side: 1 mg/m3 q Filter type AMD Nominal filtration rating: 0.01 m V V V V V Oil mist concentration on the outlet side: 0.1 mg/m3 + e Thread type Nil Rc V V V V V N*1 NPT V V V V V F*2 G V V V V V + 01 1/8 V 02
Table 3.3-1 Power supply cable and earth leakage breaker (Recommended) Earth leakage breaker Terminal Power Recommended Cable Sensitivity block Model supply crimp Specifications Breaker of screw voltage terminal 1 size leakage diameter (A) current (mA) 4 cores x AWG10 (4 cores x 5.5 mm2) HRL100-A-20 3-phase R5.5-5 30 200V AC including (50Hz) ground M5 30 4 cores x 3-phase HRL200-A-20 40 AWG8
Table 3.3-1 Power supply cable and earth leakage breaker (Recommended) Earth leakage breaker Terminal Power Recommended Cable Sensitivity block Model supply crimp Specifications Breaker of screw voltage terminal 1 size leakage diameter (A) current (mA) 4 cores x AWG10 HRL100-A-20 3-phase (4 cores x 5.5 mm2) R5.5-5 30 200V AC including (50Hz) ground M5 30 4 cores x 3-phase HRL200-A-20 40 AWG8
Table 3-3 Power supply cable and earth leakage breaker (Recommended) Earth leakage breaker *1 Terminal Cable Model Power supply block Recommended Sensitivity specifications Rated voltage screw crimp terminal of leakage *2 current diameter current (A) (mA) 380-415 VAC 4 x 5.5 mm2 50/60Hz 3 phase, (4 x AWG10) HRS200-A-46-S M5 R5.5-5 30 30 *Including 460-480 VAC 60Hz ground 3 phase *1.
45) 01-r,6NPr 02-TNPI 03-Stl.lPI 04_I'NPI N Pon thrEd Fluoro rubber E Fluororesin lining Fluoro rubber Fluoro rubber & Fluoro resin lining Port lhrad N-NPT F-PF _-Rc(Pn' *Special o.der only.
Rc NPT G Symbol N M12 3 m lead wire with connector Without lead wire Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l Port size Output specification Port size Applicable model Flow rate (l/min) Symbol Symbol Output specification 100 200 500 50 10 01 02 03 04 1/8 1/4 3/8 1/2 27 NPN open collector 2 outputs PF2A710/750 PF2A711/721 PF2A751 67 PNP open collector 2 outputs
Wiring specification Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l Rc NPT G Nil N F 3m lead wire with connector Without lead wire Nil N Output specification Port size Size Applicable model Flow rate (l/min) Nil Output specification Applicable model Symbol 10 50 100 200 500 PFA710, 750 PFA711, 721, 751 PFA711, 721, 751 NPN open collector 2 outputs 27 1/8 1/4 3/8 1/2 01 02
AU200/300 Effective thread depth 6.5 4-M5 x 0.8 AU200, 300 Float type auto-drain Port size H G F E D C B A Model Port size 1 4 / 3 8 AU200 / 50 70 61 30 40.5 31.5 164 165 AU300 50 70 61 30 40.5 31.5 188.5 165 14-3-12
2 VX3 ) VXA How to Order VN VXH2230 02 1 G LVC LVA Bracket Nil B 3 -B JIS Symbol LVH LVD Valve/Body 0 3 ' +0 Electrical option Nil 3 LVQ S ( L LQ Z + ( Port size 6 ( 2 (-' LVN 02 03 04 6 +" 6 &+$ 6 +! TI/ TIL Electrical entry G 8 PA Rated voltage C ) 2 ! >) +# = 1 >) +# = D 543 PAX T ) 3 >) +# = 6 ( 4 !! >) +# = PB 7 !"