Example) KEC-02-X2 (5) The dimensions shown in the dimension drawings are merely reference dimensions. The actual dimensions will vary depending on the tolerance. Be sure to provide sufficient clearance around the fitting for piping.
Panel adapter B ZS-22-02 Specifications PF2W300/301 PF2W330/331 Model Flow rate measurement range Note 1) 0.35 to 4.5 l/min 1.7 to 17.0 l/min 3.5 to 45 l/min 7 to 110 l/min Set flow rate range Note 1) 0.35 to 4.5 l/min 1.7 to 17.0 l/min 3.5 to 45 l/min 7 to 110 l/min Minimum set unit Note 1) 0.05 l/min 0.1 l/min 0.5 l/min 1 l/min Accumulated pulse flow rate exchange 0.05 l/pulse 0.1 l/pulse
B C d H MQ10-M MQ16-M MQ20-M MQ25-M MQ28-M NTJ-015A NT-015A NT-02 NT-03 NT-04 8 9.2 6 15.5 5 9.2 M5 x 0.8 4 10 20.5 10 8 8 9.2 8 16.5 6 11.5 M6 x 1.0 5 16 22.5 16 10 8 9.2 10 18.5 6 15 M8 x 1.25 5 20 24.5 20 13 10 11.5 12 22.5 11 19.6 M10 x 1.25 6 25 33.5 25 17 14 16 16 28.5 12 25.4 M14 x 1.5 8 30, 40 40.5 30, 40 22 Applicable bore size (mm) Part no.
LED for power supply, LED for alarm 5 to 40C (41 to 104F) Dimensions (mm) 1in=25.4mm LC6C220AD Dedicated teaching box LC51T1 02 TEACH 42 97 POWER ALM PARA AL-RES JOG MON I/O TEST 38 130 STOP SMC LC5-1-T1 TEACHING BOX 96 35 RET ESC/ $MODE 50 21
Stainless Steel Body for Low Breakway Friction Double Roc/Double End Mounting 6 Available Mounting Options Non-Rotating Option Auto Switch Capable Air Cylinder: Standard Type Series:NCM Series NCM How Toordcr NC DMrB075-02 00 C S J 851 xB6 T r I Lo**" Auto-Switch Capable I xB6 -High Temp. I XB7 -Low Temp.
Panel adapter B ZS-22-02 NPN open collector 2 outputs PNP open collector 2 outputs 0 1 Specifications Model PFW300 PFW301 PFW310 PFW311 PFW321 PFW320 Flow rate measurement and setting range Minimum setting unit 0.5 to 4 (setting is 0.6 to 4) l/min 2 to 16l/min 5 to 40l/min 0.1l/min 0.5l/min 0.05l/min Real-time flow rate l/min, gal (US)/min Accumulated flow Display units Note 1) l, gal (US
Port size Body size Thread size Port thread Symbol N F Rc NPT G 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 An interface part is required if a spacer or spacer with bracket shown in the table below is attached to a modular FRL.
Applicable power supply voltage AC 100 Solenoid valve combination symbol Pilot valve symbol Nil Y Nil Nil Y Nil Nil Nil AC 200 AC 110 AC 220 DC 24 DC 12 K1 K1 K2 J1 J1 J2 Q1 Q2 q w e r t y u i Combinations (1) to (8) in the above table are the only possible options. 2 Series ZQ Compact Vacuum Ejector How to Order ZZQ1 08 B B S Manifold Pilot exhaust port location Number of stations Note) 01 02
Part Number Description: FEEDER TUBE ASSY-02/04 Product Line: E Product Line Description: AIRLINE EQUIPMENT Family Code: 107 Family Description: ALF AUTO FEED LUBRICATOR Class Code: 21 Part Code: 2 Reference Code: J Click here to report information errorImage shown may not match exact part number
Part Number Description: DIAPHRAGM ASSY/AEP100-02 Product Line: E Product Line Description: AIRLINE EQUIPMENT Family Code: 137 Family Description: AEP LIQUID COLLECTOR Class Code: 21 Part Code: 2 Reference Code: K Click here to report information errorImage shown may not match exact part number
Part Number Description: INNER VALVE FOR IL100-02 Product Line: I Product Line Description: INSTRUMENTATION Family Code: 805 Family Description: IL100 BOOSTER RELAY Class Code: 21 Part Code: 2 Reference Code: K Click here to report information errorImage shown may not match exact part number
Part Number Description: SPRING FOR IL100-02 Product Line: I Product Line Description: INSTRUMENTATION Family Code: 805 Family Description: IL100 BOOSTER RELAY Class Code: 21 Part Code: 2 Reference Code: K Click here to report information errorImage shown may not match exact part number
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, O-RING, AIRLINE EQUIPMENT, AN SILENCER, 21, AN NO SIZE RAPART, .00220 lb
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, SPRING (FH3XG9300), OTHERS, FHG HYDRAULIC FILTER, 21, FGH NO SIZE RATING, .00000 lb
Fluid: compressed air, Noise reduction: 25-35 dB(A) or more, Maximum operating pressure: 1.0MPa, Effective area mm 2 (Cv): AN*00 35-960 (1.9-53); AN*02 35-90 (1.9-5.0); AN*03 10-60 (0.6-3.3), Ambient and fluid temperature: 5 - 60 C, SPRING (FH-TK400-10-04E), OTHERS, FHG HYDRAULIC FILTER, 21, FGH NO SIZE RATING, .00000 lb
Delivery Pressure: 02 [1 to 30 psig (0.007 to 0.2 MPa)], Material: S (Body: 316 SS; Poppet: 316 SS; Diaphragm: 316 SS), Connections, Inlet: 4 (NPT 1/4 Inch), Connections, Outlet: 4 (NPT 1/4 Inch), Gauge Port, Extra Bottom Outlet: 0 (No Pressure Gauge, Connections: 1/4 Inch NPT), Gauge Port, Inlet: 30 [0 to 3000 psig (0 to 21 MPa)], Gauge Port, Outlet: V3 [-30 in.Hg to 30 psig (-0.1 to 0.2
A [Tightening torque] L[]ZC[]3[] M3 x 0.5 x 3 deep [0.315Nm] L[]ZC[]5[] M4 x 0.7 x 4 deep [0.75Nm] L[]ZC[]3[] 8 14 Across flat 13 L[]ZC[]5[] 10 22 Across flat 21 *Use locking tool when m ounting foot. L[]ZC[]5[] M10 x 1.25 [24.5Nm] L[]ZC[]3[] M6 x 1.0 [3.0Nm] Caution Model no.
LED for power supply, LED for alarm 5 to 40C Parameter setting Indication LED Operating temperature Dimensions LC6C220AD Dedicated teaching box LC51T1 02 TEACH 42 97 POWER ALM PARA AL-RES MON JOG I/O TEST 38 130 STOP SMC LC5-1-T1 TEACHING BOX 96 35 RET ESC/ $MODE 50 21 2
DC cable 16.4 ft (5 m) Alarm output connector 4.3 (110) Signal cable 16 ft (5 m) 4.1 (103) 2.6 (65) 1.06 (27) 3.9 (100) 5.1 (130) Circulating fluid outlet (1.2 )30)) 12.6 (320) 0.8 (20) 0.8 (21) Terminal block Display panel 6.7 (170) 5.6 (143) 4.7 (120) AL SI 8.5 (215) OUT FG B B A FG + EXT.SENSOR REMOTE ON/OFF 3.8 (97) 3.1 (79) ALARM PURGE OUT PURGE IN SIGNAL Purge inlet (M5) Fluid leak
Alcohol Ethyl alcohol IPA Methyl alcohol Anti-freeze Adhesives Oil Gasoline Kerosene Ester Dimethyl phthalate Diethyl phthalate Acetic acid Recommended Torque Unit: lbfft [Nm] Synthetic oil Anti-rust additives Connection thread 1/4 3/8 1/2 Torque 8.9 to 10 [12 to 14] 16 to 18 [22 to 24] 21 to 22 [28 to 30] Ether Methyl ether Ethyl ether Brake oil additives 2.