Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 150/75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 150/110, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 200/190, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 260/140, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 300/150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: With Intermediate Stop Function / Stroke with Adjustment, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.1~1.0, Support bracket:
(50) PFM711--D/F 100(50) ( )CO2 ( ) CO2 () 25[L/min] 10[L/min] [L/min] [L/min] 50[L/min] 100[L/min] [L/min] [L/min] -57No.PF-OMJ0005CN-I (350[kPa]) 25[L/min] 10[L/min] [kPa] [kPa] [L/min] [L/min] 100[L/min] 50[L/min] [kPa] [kPa] [L/min] [L/min] -58No.PF-OMJ0005CN-I PFM7-(N)01/(N)02/F01 17 2 -59No.PF-OMJ0005CN-I PFM7-(N)01L/(N)02L/F01L 2 17 -60No.PF-OMJ0005CN-I PFM7S-(N)01/(N)02/F01
Repetition Pressure characteristics Flow characteristics 0 1 10kPa 20kPa -20 Output deviation factor % F.S. 0.5 40kPa -40 Set pressure kPa Out 60kPa -60 0 Return 80kPa -80 -0.5 100kPa -100 -120 -100 -80 -60 -40 -1 0 1 1.5 0.5 2 2.5 3 3.5 -120 -20 4 Flow rate l/min (ANR) Supply pressure MPa 5 Compact Electro-pneumatic Regulator Series ITV0 Dimensions Single unit 4-6 2-6 PWR L bracket (optional
Closed center SQ1000 SQ1331 33 or less 0.16 0.26 0.58 0.15 0.20 0.64 25 or less Rubber seal 100 SQ1430 26 or less 0.14 0.14 0.60 0.14 0.12 0.58 20 or less Metal seal 100 Exhaust center SQ1431 33 or less 0.19 0.20 0.80 0.15 0.20 0.64 25 or less Rubber seal 100 SQ1530 26 or less 0.14 0.14 0.63 0.14 0.12 0.62 20 or less Metal seal 100 Pressure center Courtesy of Steven Engineering, Inc.-230
Note 7) Fixed unit: kPa 100 to 100 kPa/PNP open collector 2 outputs, with suction filter 100 to 100 kPa/NPN open collector 1 output + analog voltage, with suction filter 100 to 100 kPa/PNP open collector 1 output + analog voltage, with suction filter Suction filter only !
Repetition Pressure characteristics Flow characteristics 0 1 10kPa 20kPa -20 Output deviation factor % F.S. 0.5 40kPa -40 Set pressure kPa Out 60kPa -60 0 Return 80kPa -80 -0.5 100kPa -100 -120 -100 -80 -60 -40 -1 0 1 1.5 0.5 2 2.5 3 3.5 -120 -20 4 Flow rate l/min (ANR) Supply pressure MPa 5 Compact Electro-pneumatic Regulator Series ITV0 Dimensions Single unit 4-6 2-6 PWR L bracket (optional
200 3 400 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) 6 Effective area (mm2) Effective area (mm2) Effective area (mm2) 06, 08 08, 10 1.0 300 06 04 2 4 50 100 200 0.5 1 2 100 0.0 0 0 0 0 0 0 5 10 0 5 10 0 5 10 Number of needle rotations (turns) Number of needle rotations (turns) Number of needle rotations (turns) ASG520F-03 ASG521F-03 ASG620F-04 ASG621F-04 Inlet
Max. operating frequency Lubrication Manual override Mounting orientation Impact/Vibration resistance Note 2) Enclosure Dustproof Electrical entry Grommet, DIN terminal 100, 200, 110, 220, 240 DC AC (50/60 Hz) Coil rated voltage (V) 24, 12 Allowable voltage fluctuation 15 to +10% of rated voltage 12.7 VA (50 Hz), 10.7 VA (60 Hz) 7.6 VA (50 Hz), 5.4 VA (60 Hz) Without indicator light: 4 W,
(1000 L type) [1000] 1000 L/min (2000 L type) [P_2 ] Set value of OUT2 5% of maximums rated flow range [ 25] 25 L/min (500 L type) [ 50] 50 L/min (1000 L type) [ 100] 100 L/min (2000 L type) [F 2] 3 Page 46 [H_2 ] Hysteresis of OUT2 [dtH2] ON delay time [0.00] 0.00 s [dtL2] OFF delay time [0.00] 0.00 s [CoL ] Display colour of OUT2 [1SoG] Green when ON, Red when OFF (OUT1) [F 3] [FiL ] Digital
[1000] 1000 L/min (2000 L type) [P_2 ] Set value of OUT2 [F 2] 3 Page 42 5% of maximums rated flow range [ 25] 25 L/min (500 L type) [ 50] 50 L/min (1000 L type) [ 100] 100 L/min (2000 L type) [H_2 ] Hysteresis of OUT2 [dtH2] ON delay time [0.00] 0.00 s [dtL2] OFF delay time [0.00] 0.00 s [CoL ] Display colour of OUT2 [1SoG] Green when ON, Red when OFF (OUT1) [F 3] [FiL ] Digital filter
PSE570 PSE573 PSE574 Rated pressure range 0 to 1 MPa -100 to 100 kPa 0 to 500 kPa Pressure spec. Withstand pressure 3.0 MPa 600 kPa 1.5 MPa Temperature characteristics (Based on 25 oC) 2%F.S. (0 to 50 oC) 3%F.S. (0 to 50 oC) 3%F.S. (-10 to 60 oC) 4%F.S. (-10 to 60 oC) Model No.
P 500 150 144 400 104 100 300 P 66 43 26 16 90 200 50 56 34 22 14 8 5 100 0 0 20 30 40 50 60 70 80 90 100 10 20 30 40 50 60 70 80 90 100 10 Bore size (mm) Bore size (mm) 1.15-33 Series VY511/VYU5 Precautions Be sure to read before handling. Refer to p.0-26 and 0-27 for Safety Instruction and common precautions on the products mentioned in this catalog.
Sleeveless Superior tube mounting Fluid temperature Sleeve 65 to 260C (Swivel elbow: 5 to 150C) Union nut Light tightening torque Comparison with conventional model 60% down Approx.
P2: Nozzle internal pressure P1: Atmospheric pressure Nozzle Diameter Flow Characteristics (Vacuum) Nozzle Diameter Flow Characteristics (Positive pressure) 5.0 5.0 0.6 0.5 4.5 4.5 4.0 4.0 0.4 3.5 3.5 0.6 Flow rate [l/min] Flow rate [l/min] 3.0 3.0 0.3 2.5 2.5 0.5 2.0 2.0 1.5 1.5 0.4 0.2 1.0 1.0 0.3 0.5 0.5 0.1 0.2 0.1 0.0 0.0 80 60 40 20 0 0 50 100 150 200 250 300 P2 [kPa] P2 [kPa] Example
ISA2-G ISA2-H Detection nozzle: 1.5 Detection side piping: 6 x 4 tubing 5 m Supply pressure: 100 kPa Detection nozzle: 2.0 Detection side piping: 6 x 4 tubing 5 m Supply pressure: 100 kPa Detection distance-Response time characteristics Detection distance-Response time characteristics Detection nozzle: 1.5 Detection side piping: 6 x 4 Supply pressure: 100 kPa Set distance: 0.15 mm Detection
200 150 100 50 0 50 100 150 200 250 150 100 50 0 50 100 150 150 100 50 0 50 100 150 (250) (200) (150) (100) (50) 0 50 100 150 200 250 (650) (550) (450) (350) (250) (150) (50) 50 150 250 350 450 550 650 0 0 mm () mm Installation distance in depth from ionizer to work piece [mm] Installation distance in widthfrom ionizer to work piece [mm] 50 50 100 100 1s 150 150 2s 200 200 0.5s 1s 2s 250