Rated Pressure Range: -0.1 to 1 MPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]
Socket/Plug: P (Plug), Thread Port Size: N02 (NPT 1/4), Barb Fitting Port Size: Not Applicable, Nut Fitting Port Size: Not Applicable, One-touch Fitting Port Size: Not Applicable, Connection Type: F (Female Thread)
Socket/Plug: S (Socket), Thread Port Size: N02 (NPT 1/4), Barb Fitting Port Size: Not Applicable, Nut Fitting Port Size: Not Applicable, One-touch Fitting Port Size: Not Applicable, Connection Type: F (Female Thread)
This is a legacy product, and replaced byAC21-N02-V-2Z-B-X2217, F/R/L COMBO UNIT EPOXY COATED, AIRLINE EQUIPMENT, AC MASS PRO, DC, AC MASS PRO 1/4 MODULAR (NPT), .00000 lb
Series PSE digital pressure switches allow pressure to be controlled from a remote location.? Series PSE510 is compact and lightweight, allowing the sensor to be mounted where needed. The use of stainless steel for all wetted parts (SUS630 for diaphragm, SUS304 for fitting) allows the PSE520 pressure sensor to be used in a wide variety of gas and fluid applications. Pressure sensor for general
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, SENSOR, GENERAL FLUID SWITCH, INSTRUMENTATION, PSE200/300/530-560, DB, PSE200/300/530-560 1/4" NPT, 0.59685 lb
Series PSE digital pressure switches allow pressure to be controlled from a remote location. Series PSE510 is compact and lightweight, allowing the sensor to be mounted where needed. The use of stainless steel for all wetted parts (SUS630 for diaphragm, SUS304 for fitting) allows the PSE520 pressure sensor to be used in a wide variety of gas and fluid applications. Pressure sensor for general
Valve Stations: 04 (4 Stations), Port Size: C2 (ø2 One-Touch Fitting), Voltage: 5 (24VDC), Coil Specifications: T [w/Power-Saving Circuit (Continuous Duty Type)(+COM)], Operating Pressure Range: L [High Flow Type (0 to 0.3 MPa)], Connector Cable: C3 (Length 1000mm), Bracket: F (With Bracket)
Valve Stations: 08 (8 Stations), Port Size: C2 (ø2 One-Touch Fitting), Voltage: 5 (24VDC), Coil Specifications: NT [w/Power-Saving Circuit (Continuous Duty Type)(-COM)], Operating Pressure Range: L [High Flow Type (0 to 0.3 MPa)], Connector Cable: C3 (Length 1000mm), Bracket: F (With Bracket)
Valve Stations: 04 (4 Stations), Port Size: C2 (ø2 One-Touch Fitting), Voltage: 5 (24VDC), Coil Specifications: T [w/Power-Saving Circuit (Continuous Duty Type)(+COM)], Operating Pressure Range: L [High Flow Type (0 to 0.3 MPa)], Connector Cable: C1 (Length 300mm), Bracket: F (With Bracket)
Valve Stations: 04 (4 Stations), Port Size: C2 (ø2 One-Touch Fitting), Voltage: 6 (12VDC), Coil Specifications: T [w/Power-Saving Circuit (Continuous Duty Type)(+COM)], Operating Pressure Range: L [High Flow Type (0 to 0.3 MPa)], Connector Cable: C1 (Length 300mm), Bracket: F (With Bracket)
Valve Stations: 08 (8 Stations), Port Size: C2 (ø2 One-Touch Fitting), Voltage: 5 (24VDC), Coil Specifications: T [w/Power-Saving Circuit (Continuous Duty Type)(+COM)], Operating Pressure Range: L [High Flow Type (0 to 0.3 MPa)], Connector Cable: C3 (Length 1000mm), Bracket: F (With Bracket)
Pressure Range: ISE70G (0 to 1 MPa), Piping: N02 (NPT 1/4), Orifice: None, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: B (Bracket B)
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N02 (NPT1/4), Piping Entry Direction: L (Bottom), Output Specification: 1 [Analog Output (1 to 5 V)]
Flow Rate Range: 11 [2 to 100 (50 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N02 (NPT1/4), Piping Entry Direction: L (Bottom), Output Specification: 2 [Analog Output (4 to 20 mA)]
Rated Pressure Range: -0.1 to 1 MPa, Output Specification: IO-Link/Switch: 1 Output (PNP or NPN), Switching Type for Switch Output, Unit Specification: M (SI Unit Only), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)]
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)