Parameter definition and setting 35 Hardware Configuration 56 GSDML file and icons 56 Configuration layout 56 Connection to SIEMENS PLC S7 57 Setting of parameters 62 I/O Map 65 Diagnostic 66 Diagnostics assignment to input map 66 Accessories 71 -1No.EX-OMQ0016 Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.

(Refer to page 35 the section "Setting and Adjustment" for details.) -13No.EX-OMW0006-D Remote The construction of the remote is shown below.

HECR008-W HECR012-W 1 Unused BUS + 0 0 Operation temp. range 10.0 to 60.0 C (No dew condensation) 5 4 3 2 1 0 10 20 30 40 50 60 70 0 10 20 30 40 50 60 70 During operation or maintenance of the product, do not disable the Communication Indication temp. range -9.9 to 80.0 C 2 RXD (RD) Unused Circulating fluid temp. deg.C Circulating fluid temp. deg.C connector Temp: 10 to 35 C Humidity : 35

(fluid: Dry air) Temperature characteristics 2%F.S. max. (15 to 35 C) 5%F.S. max. (0 to 15 C, 35 to 50 C) Pressure characteristics 5%F.S. max. (0.35 MPa reference) Rated pressure range -70 kPa to 750 kPa Proof pressure 1 MPa 50 msec. Response time (when "Select response time" wire (white) is connected to GND, response time is 1 sec.)

. *6) The output is updated on the transition of (ONOFF) of the DRIVE input signal. 35 - The following table shows the relation of the positon number and the combination of IN0-IN5 or OUT0-OUT5. 0OFF 1ON 0OFF 1ON Step No IN5 IN4 IN3 IN2 IN1 IN0 Step OUT OUT OUT OUT OUT OUT No 5 4 3 2 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0 0 0 0 1 1 0 0 0 0 0 1 2 0 0 0 0 1 0 2 0 0 0 0 1 0 3 0 0 0 0 1 1 3 0

(Tensile force 35 N or less) Hold the body when handling to avoid the damage of the Pressure switch which lead to cause the failure and malfunction. For piping of the Pressure switch, hold the piping with a spanner on the metal part of the piping (Piping attachment). Holding other part with spanner leads to damage the Pressure switch.

2 switches (Different side) 100 2 switches (Same side) D-A3 D-G39 D-K39 35+30(n2) n = 2, 3, 4 Other qty.

The fixing bolts of cover Bolt type Bolt size Recommended tightening torque (Nm) Quantity M4 x 35 (LEJ40) M4 x 40 (LEJ63) 0.90.1 4 Cross recessed pan head screw Belt (for speed reduction) 8. Troubleshooting When a fault occurs during the operation, the corresponding alarm or warning is displayed.

(See Appendix 8.1.2 Communication specification on page 8-4 for details.) 11 E_OUT TEMP READY, AUTO PURGE*1 12 F.LOW TEMP 5 to 10C Issues an alarm of F.Water Low Temp WRN if the facility water falls below the set temperature. 13 F.HIGH TEMP 35 to 50C Issues an alarm of F.Water High Temp WRN if the circulating fluid exceeds the set temperature.

Avoid using in a place where the ambient humidity is outside the specified humidity range (35 to 80% Rh) c. Avoid using in a place where condensation occurs due to a drastic temperature change. d. Avoid using in a place in the presence of corrosive or explosive gas or where there is a volatile combustible. e.

XSA3-3P(N) 40 40 88 40 16.5 24.5 3/8 29 32 77.5 35 64 52.5 71.5 28 77.5 69.5 69.5 57.5 104.5 71.5 73.5 5 10 13 XSA-OMS0001-A 4.

SI Unit 35 6.1. Parts and description 35 6.2. Specifications 37 6.3. Process data for valves 39 6.4. LED indicators 40 6.5. Block diagram 43 7. Digital Input Module EX245-DX1 46 7.1. Parts and description 46 7.2. Specifications 47 7.3. Wiring 48 7.4. Process data 48 7.5. LED indicators 49 7.6. Block diagram 50 8. Digital Output Module EX245-DY1 51 8.1. Parts and description 51 8.2.

/Refer to the operation manual of LEC (controller) for details of wiring. -35- 6. Electric actuators / Low profile slider type Common precautions 6.1 Design and selection Warning 1. Do not apply a load in excess of the actuator specification. A product should be selected based on the maximum work load and allowable moment.

Workpiece mass: 0.05 kg Pressure 0.6 MPa 30 0.5 25 0.4 Gripping force (N) 20 0.3 15 13 0.2 10 0.1 5 0 20 30 50 60 40 70 Gripping point L (mm) When MHY2-16D is selected, the gripping force is determined to be 13 N according to the gripping point distance (L = 35 mm) and the pressure (0.4 MPa).

Symbol -X2172 With Boss in Head End 3 Z X2172 MKB Bore size Stroke Rotary direction Body option With boss in head end 2 Bore size 20 25 32 40 50 63 Ah9 13 15 21 28 35 35 0 0.043 0 0.043 Ah9 0 0.052 0 0.052 0 0.062 0 0.062 Symbol -X2177 The Dimension of Head End Flange is the Same as the Current MK and MK2 Series 4 Z X2177 MKG Bore size Stroke Rotary direction Body option The dimension of

Applicable cylinder ML2B25 ML2B32 ML2B40 MY-S25A M6 x 1 35 50 8 5 9.5 5.5 B MY-S32A M8 x 1.25 45 64 11.7 6 11 6.6 B Guide for Side Support Application For long stroke operation, the cylinder tube may be deflected depending on its own weight and the load weight. In such a case, use a side support in the middle section.

TC TH TV TW TX TY MI W S CJ-T010B 6, 10 4.5 29 40 22 32 12 CEP1 CJ-T016B 16 5.5 35 48 28 38 16 Note) For details, refer to page 10-5-24.

See Specific Product Precautions. 0.2 GD 0 0 10 20 30 40 50 Operating temperature (C) Port size Model Rated flow (L/min (ANR)) Note 1) Weight 60 80 100 100 100 100 300 400 500 500 35 g 35 g 35 g 35 g 60 g 150 g 190 g 190 g 190 g 260 g 4 (One-touch fittings) 6 (One-touch fittings) 8 (One-touch fittings) Rc, NPT, G 1/4 Rc, NPT, G 1/4 Rc, NPT, G 1/4 8 (One-touch fittings) 10 (One-touch fittings

pressure (kPa) 500 -35 400 -48 300 -61 200 -75 100 -88 -101 0 Hastelloy is a registered trademark of Haynes International.

6 12 4.5 30 12 14.5 46 70.5 9 2-M5 0.8 with depth 7.5 32 2-M6 1.0 94 37 100.5 92 35 17.5 75 45 8 16 4 30 16 18.5 56 80.5 10 Symbol Z Stroke 10.20 30.40.50 Bore size (mm) 75 100 15 20 25 32 25 35 45 55 30 40 60 60 30 40 60 60 40 50 70 70 13 Compact Type Dual-Rod Cylinder Series CXSJ Proper Auto Switch Mounting Position for Stroke End Detection CXSJ6, 10 Auto switch model Bore size Operating