Applicable rotary actuator Applicable air gripper Size Page Size 30 50-100 10/15 20-100 10/15 20-40 32/40 1/3 7/20 10-200 10-25 10-25 10-40 10-30 16-25 32-125 10-25 32-63 20-50 CDRA1 CDRB CDRQ MRQ MDSUB MSQ MHZ2 MHZJ2 MHL2 MDHR MHS 12-25 MHK MHS MHC2 MHT2 MHW2 10-25 10/16 MHY MRHQ 2.11-8 D-A72/A73/A80 Grommet D-A72H/A73H D-A76H/A80H 2.11-9 Rail Connector 2.11-10 D-A73C/A80C D-A53/A54/A56
Used as IO-Link device 18 to 30 VDC, including ripple (p-p) 10% Current consumption 25 mA or less Protection Polarity protection Switch output Select from NPN or PNP open collector output Max. load current 10 mA Max. applied voltage 30.0 V Residual voltage 1 V or less (at 10 mA) Short circuit protection Provided 2-screen (3-screen display available: sub display, 4 digits x 2) Main display
ASCII code 5 characters Refer to 5.12.11 Communication example. | 0062h 10 decimal number 0 to 4294967295 16 hexadecimal number 0h to Fh 4 bytes 0063h upper level 0064h lower level 0064h 0063h Control board Program No. 10 decimal number 0 to 65535 16 hexadecimal number 0h to Fh 0065h Control board R Program version 10 decimal number 0 to 4294967295 16 hexadecimal number 0h to Fh 4 bytes 0063h
(Becomes close to the trapezoidal acceleration as the setting value reaches 0) Acceleration and deceleration ratio 10 10 10 to 100 EQY251 to 50 EQY321 to 70 Torque when held *2 50 70 Sets the torque when stopped after the positioning operation. (Unit: %) H 150 100 Sets the position loop P constant.
Note 8) : For pipe thread type: NPT only 1069 A Air Filter 1021-AF-A Standard Specifications Model 10-/21-AF20-A 10-/21-AF30-A 10-/21-AF40-A 1 10-/21-AF60-A 10-/21-AF40-06-A 10-/21-AF50-A Port size 1/8, 1/4 1/4, 3/8 1/4, 3/8, 1/2 3/4 3/4, 1 Fluid Air Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa 5 to 60C (No freezing) Ambient & fluid temperature 5 m Nominal filtration rating 1600
Target position: 100.000[mm] (=10 [m] = 186A0h) Target speed: 100[r/min] (=10 [0.01r/min] = 2710h) Acceleration time constant: 100 [ms] (= 64h) Deceleration time constant: 100 [ms] (= 64h) The setup value is as follows.
Lead wire with connector for copying ZS-40-Y Connect up to 10 slave units 10 LFE0 Series For the flow switch precautions, refer to the Operation Manual on the SMC website.
Approx. 5.6k Switch DICOM 24VDC 10% 150mA Approx. 5mA VCES 1.0V ICEO 100 A (2) Digital output interface DO-1 A maximum of 2.6V voltage drop occurs in the driver. If polarity of diode is reversed, servo amplifier will fail. Servo amplifier Driver driver ALM, etc. Load DOCOM (Note) 24VDC 10% 150mA Note.
/O.D. mm Symbol Symbol Symbol 01 02 03 04 N01 N02 N03 N04 07 09 11 13 06 08 10 12 07 09 11 13 6 8 10 12 1/4" 5/16" 3/8" 1/2" R, Rc1/8 R, Rc1/4 R, Rc3/8 R, Rc1/2 NPT1/8 NPT1/4 NPT3/8 NPT1/2 50 60 65 80 85 110 5/8 6/9 6.5/10 8/12 8.5/12.5 11/16 Metric size The figures in ( ) indicate the internal diameter of the applicable hose.
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 4 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 5 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low tank fluid level 1 CH1 abnormal high circulating fluid temp. 2 Reservation
CN2: TB/PC connector.31 9. 1 How to use.31 10. LED display.32 10. 1 LED display.32 10. 2 Controller IF communication status and LED display.33 11. Mode.34 11. 1 Outline.34 11. 2. Step data input mode .34 11. 3. Numerical data input mode.34 11. 4. Data writing mode.36 12.
Basic type Select type Model VEX5504 06 10 VEX57-10 12 VEX59-14 20 P1 P1 VEX VEX Description Bracket (With bolt and washer) G46-10-01 VEX7-32A VEX5-32A VEX9-32A Air operated External pilot solenoid valve 3(R) 3(R) Pressure gauge 1(P) 3(R) 3(R) 1(P) P2 P2 P3 P1 P1 3(R) 3(R) 3(R) 3(R) 1(P) 1(P) P2 P2 Note) With this valve, the port 3(R) is a supply port and port 1(P) is an exhaust port. 2441
Rod O.D.Applicable tubing O.D. 10 20 25 30 M5 standard 01 standard 02 standard 03 standard 04-04 06-06 08-08 10-10 4 4 6 6 8 8 10 10 wBring up the body, while holding it down. w eTake the finger off the release ring and remove the speed controller from the One-touch fitting.
YB-03 32, 40 80 9 6.5 10 18 50 d2 d1 YB-05 50, 63 120 11 6.5 12 22 60 L UT C UA (mm) Part No.
CN2: TB/PC connector.31 9. 1 How to use.31 10. LED display.32 10. 1 LED display.32 10. 2 Controller IF communication status and LED display.33 11. Mode.34 11. 1 Outline.34 11. 2. Step data input mode .34 11. 3. Numerical data input mode.34 11. 4. Data writing mode.36 12.
VSS8-6 VSS8-8 VSS8-10 VSS8-6 VSS8-8 VSS8-10 Description Description VSS8-10 VSS8-8 VSS8-8 VSS8-10 VSS8-6 VSS8-6 VSS8-10 VSS8-8 VSS8-6 1.
Direct Operated Precision Regulator/Modular Style (For Special Applications) -ARP20 to -ARP40 10 20 21 10 20 21 JIS symbol Direct Operated Precision Regulator with Backflow Function/Modular Style (For Special Applications) Regulator with backflow function Regulator -ARP20K to -ARP40K 10 20 21 10 20 21 Clean room compliant (10-ARP). Copper-free, fluorine-free (20-ARP).
XT53440 05 Number of stations 05 06 12 1 station 2 station 8 station 13-9-10
Extension locking Retraction locking 100 100 63 63 50 50 40 Load mass kg Load mass kg 40 10 10 32 32 0.5 MPa 0.4 MPa 0.5 MPa 0.4 MPa 1 1 100 500 100 500 Maximum speed mm/s Maximum speed mm/s Allowable load mass (Graph (2)) Horizontal (With and without switch) 10 Load mass m (kg) 1 63 50 40 32 m 0.1 10 100 Eccentric distance + Stroke L (mm) l S l: Eccentric distance (mm) S: Stroke (mm) L Cushion