Search Results "CXS2L20-200"

Flow rate 20 L/min (ANR) Condition: Inlet pressure 0.7 MPa Flow Characteristics (Representative values) Pressure Characteristics (Representative values) ARP20(K) ARP20(K) Rc 1/4 0.50 0.25 0.45 ARJ 0.40 AR425 to 935 Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point 0.30 ARX 0.20 0.25 AMR 0.20 ARM 0.15 0.10 ARP ARP 0.05 IR 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 50 100 150 200

rate 20 L/min (ANR) Condition: Inlet pressure 0.7 MPa Flow Rate Characteristics (Representative values) Pressure Characteristics (Representative values) ARP20(K) ARP20(K) Rc 1/4 0.50 0.25 0.45 ARJ 0.40 AR425 to 935 Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point 0.30 ARX 0.20 0.25 AMR 0.20 ARM 0.15 0.10 ARP ARP 0.05 IR-A 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 50 100 150 200

pressure 0.5 MPa Outlet pressure 0.2 MPa Flow rate 20 l/min (ANR) Condition: Inlet pressure 0.7 MPa Flow Characteristics (Representative values) Pressure Characteristics (Representative values) ARP20(K) ARP20(K) Rc1/4 0.50 0.25 0.45 0.40 Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point 0.30 0.20 0.25 0.20 0.15 0.10 0.05 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 50 100 150 200

The maximum detectable piston speed is: Auto switch operating range (mm) Time load applied (ms) x 1000 V (mm/s) = In cases of high piston speed, the use of an auto switch (D-F5NT, F7NT, G5NT, M5NT, M5PT) with a built-in OFF delay timer ( 200 ms) makes it possible to extend the load operating time.

Yes A90V Grommet IC circuit 100 V or less No Yes No Yes No 100 V, 200 V Relay PLC 200 V or less 12 V Connector 2-wire 24 V IC circuit 24 V or less PLC Terminal conduit 100 V, 200 V Yes Relay PLC DIN terminal Grommet Diagnostic indication (2-color indicator) 1 Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance

Fittings & Tubing Air Cylinders Rotary Actuators ARP20(K) 1021 ARP20(K) 1021 Rc1/4 0.50 0.25 0.45 0.40 Outlet pressure (MPa) Outlet pressure (MPa) 0.35 Set point 0.30 0.20 0.25 0.20 0.15 0.10 0.05 0.15 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.00 0 50 100 150 200 250 300 Flow rate (L/min (ANR)) Inlet pressure (MPa) 1021 1021 ARP30(K) ARP30(K) Rc3/8 0.50 0.25 0.45 Air Preparation Equipment 0.40

300 40 30 20 10 0 30 25 20 15 10 5 0 Load (N) Load (N) MSQXB30A MSQXB50A 350 300 300 250 Displacement (m) Displacement (m) 250 200 200 150 150 100 100 50 40 30 20 10 0 100 80 60 40 20 0 Load (N) Load (N) 336 MSQX Series Low-Speed Rotary Table Rack & Pinion Type Construction CRB2 CRB1 MSU CRJ CRA1 o i @5 @6 t y !

CD-P11 CD-P12 Load voltage 24 VDC 100 VAC or less 200 VAC Note) Hysteresis may fluctuate due to the operating environment. Please contact SMC if hysteresis causes an operational problem.

VK300-82-2-01 VK300-82-2-03 110 VAC 110V 200 VAC 200V VK300-82-2-02 VK300-82-2-04 220 VAC 220V VK300-82-2-07 VK300-82-4-51 VK300-82-4-06 VK300-82-3-05 VK300-82-3-53 240 VAC 240V 6 VDC 6V 12 VDC 12V 24 VDC 24VD 48 VDC 48VD 3-2-11

(Values at the initial period) Solenoid Specifications Electrical entry Grommet (G), DIN terminal (D) 100, 110, 200, 220, 240 12, 24 10% of rated voltage 9.5 VA/50 Hz, 8 VA/60 Hz 7 VA/50 Hz, 5 VA/60 Hz 3.5 VA/50 Hz, 3.3 VA/60 Hz 3 VA/50 Hz, 2.8 VA/60 Hz 4 W (Standard), 2 W (Low power consumption type) 4.3 W (Standard), 2.3 W (Low power consumption type) Varistor Diode (Varistor for 12 VDC

Port size (P, A and B port) Rated voltage M5 01 M5 x 0.8 1 2 3 4 5 6 7 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 110 VAC, 50/60 Hz 220 VAC, 50/60 Hz 1 8 R1, R2: M5 Option 24 VDC 12 VDC Nil None With bracket (Not assembled) 240 VAC, 50/60 Hz For other rated voltages, please consult with SMC. F Option Part No. Description Part no.

power [VA]*1 AC 200 V 1.15 (With light: 1.30) 220 V [230 V] 1.27 (With light: 1.46) [1.39 (With light: 1.60)] Surge voltage suppressor Varistor (DC) Indicator light LED (DC), Neon bulb (AC) *1 The 110 VAC and 115 VAC are interchangeable.

VXB215 B E(H) 100 300 400 500 600 200 VXB215 C F(H) 100 300 400 500 600 700 800 200 Flow rate Q [kg/h] How to read the graph The sonic range pressure to generate a flow rate of 300 kg/h is P1 0.3 MPa for the VXB215C F(H).

400 ---1 ---1 100 200 Air consumption Air consumption 0 0 0 0 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.0 0.1 0.2 0.3 0.4 0.5 0.6 Supply pressure [MPa] Supply pressure [MPa] ZH30-X185 ZH40-X185 ---7 ---7 3,500 5,000 Suction flow rate [L/min (ANR)] Note 1) Air consumption [L/min (ANR)] Discharge flow rate [L/min (ANR)] Suction flow rate [L/min (ANR)] Note 1) Air consumption [L/min (ANR)] Discharge flow

(Max. 200 L/min (ANR)) Air Suction Filter with One-touch Fittings/ In-line Type ZFC IN/OUT straight piping One-touch fittings for easy installation and remove Lightweight molded resin parts Cartridge type allows element replacement.

(Max. 200 L/min (ANR)) Air Suction Filter with One-touch Fittings/ In-line Type ZFC IN/OUT straight piping One-touch fittings for easy installation and remove Lightweight molded resin parts Cartridge type allows element replacement.

Note) Auto shift input time Series PSE 200: 10 [ms] or longer Other series: 5 [ms] or longer Hi Auto shift input time Lo Note) Auto shift input time Series PSE 200: 10 [ms] or longer Other series: 5 [ms] or longer 885 Technical Information Auto shift function 12 2-wire pressure switch connections 13 A 3-wire type switch is a switch that has an output line other than the positive and negative

RSH80 RSH80 RSH80 200 200 RSH63 RSH63 RSH63 RSH50 RSH50 RSH50 0.9 Operating pressure : P (MPa) 100 100 0.8 0.7 0 0 10 20 30 40 10 20 30 40 Load speed : u (m/min) m=0.1 0.6 Load speed : u (m/min) m=0 0.5 0.4 Graphe Graphr Bore size 20, 32/ m =0 Bore size 20, 32/ m =0.1 0.3 0.2 0.1 80 80 1000 2000 3000 4000 5000 0 32 Lateral load: W (N) 70 70 60 60 50 50 Weight : W (kg) Weight : W (kg) 32 40

Suitable 20 for m and 0.7 for . 1000 ML2B 6 10 15 20 25 30 40 50 63 80 100 125 140 160 180 200 250 300 0.057 0.099 0.113 0.120 0.184 200 300 400 500 E1 4.9 J In the case of cylinder stroke at load and free horizontal impact, 0.157 0.274 0.314 0.334 0.511 C J G5-S E1 or E substitute respective figures for Data A in order to calculate E1. 100 Impact object weight m or corresponding weight

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 0.1 0.05 0.01 50 100 300 200 (141) 500 Maximum speed (mm/s) 2. Rod end allowable lateral load Make sure that the lateral load that is applied to the rod end will be no more than the values shown in the tables.