x 103 M Yaw moment M3 = m x g x (L + A) x 103 M Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYP15 CYP32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m : Load mass [kg] L : Distance to load center of gravity [mm] A, B : Distance to guide shaft [mm] g : Gravitational acceleration [9.8m/s] M2 M1 M3 m x g m x g Guide shaft mounting surface m x g Guide central axis Cylinder
x 103 M Yaw moment M3 = m x g x (L + A) x 103 M Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYP15 CYP32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m : Load mass [kg] L : Distance to load center of gravity [mm] A, B : Distance to guide shaft [mm] g : Gravitational acceleration [9.8m/s] M2 M1 M3 m x g m x g Guide shaft mounting surface m x g Guide central axis Cylinder
A C F U U M V E A V L Heater (Option) (Maintenance space) Auto switch (Option) B J XLA XL H XLQ XLQ G XM XY DXSA A XVD XGT CYV A (mm) Model A 120 133 178 190 B 38 48 66 79 C 1 1 2 2 D 12 11 11 E 30 40 55 75 F 17 26 41 52 G 40 39 63 68 H 87 91 129 142 J XLAQ-16 XLAQ-25 XLAQ-40 XLAQ-50 40 50 65 70 Note) The heater (Option) is not available with XLAQ-16. 471 Aluminum One-touch Connection and
(Refer to page 5 for detailed specifications of the contact protection boxes.) 6.2 5.7 3.4 12.5 Most sensitive position 8 Solid State Auto Switches/Direct Mount Type D-Y59 /D-Y69 /D-Y7P (V) A B A B Auto Switch Specifications D-Y5, D-Y6, D-Y7P, D-Y7PV (with indicator light) D-Y7PV D-Y59B D-Y59A D-Y69A D-Y7P D-Y69B Auto switch part no.
12 V 5V, 12 V 12 V 5 V, 12 V 12 V IC circuit Solid state switch Reed switch IC circuit Relay, PLC Diagnosis (2-color indication) 24 V Grommet Yes IC circuit Water resistant (2-color indication) M9PAV M9BAV A96 A93 A90 A96V A93V A90V IC circuit IC circuit 5 V 12 V 3-wire (NPN equivalent) Yes Grommet 100 V Relay, PLC 2-wire 24 V No 5 V,12 V 100 V or less Water resistant type auto switches
N06 NPT3/4 5/16(inch) N04 2xNPT1/2 6) 5 DC24V *1G JIS B0202 ISO1603 ISO1179 8) Z 7 L L 0.3(m) 11) A NPN LO B PNP M M 0.3(m) MO 12) 9) M SI (kPa) D P (:psi) E 10) 14 GN (G) B G *7ZL212 27mm ZL212 (2 /1 , 4 ) E (2 ) F (2 ) V (1 ) 13 G 2m) W (2m) 5 No.ZL3-OM00801-A 2. 2.1 (1/P) (2/V) ZL3 ZL6 (3/E) // / (G) (2/V) 2.2 ZL6 1 ZL6 (ZL6-SC1-A) 2), 6 No.ZL3-OM00801-A 3. 3.1
(Looked by double solenoid valve) (Looked by double solenoid valve) SOL. location B (*) B (*) B B A B A B A B A B A A A A B A B A SOL. location VQC 3 position 3 position Double Double Double Double SI unit Single Single SI unit Single Single SQ Stations 1 2 3 4 5 Stations 1 2 3 4 5 VQ0 The places of asterisk are not used.
A B C D Maximum Speeds for Each Transfer Load Unit (mm/s) Transfer load (kg) 15 20 25 30 1000 1000 930 740 600 500 Model Note LJ1H202PC-500LJ1H202PC-600LJ1H202PC-700LJ1H202PC-800LJ1H202PC-900LJ1H202PC-1000700 700 600 600 500 500 500 500 500 500 500 500 500 500 500 500 500 500 Power supply: 100/110(V)AC 10% Compatible controller: LC1-1B2H1Power supply: 200/220(V)AC 10% Compatible controller
V MC1 THR TB1,2 SWL PRR PRS1 PRS2 PRS3 PLC HM GFCI EDV IDF100F150F-W 6 6 IDX-OM-Z004 6 6.5 Y Y ,, IDF100F150F-W 6 7 IDX-OM-Z004 6 6.6 () (1) ADH-E400 V 1 -(2) 1 1 ) 1 2 ) Y92S-36/CR2477/ () 1 B 20,000 (6 ) 1 B 20,000 (6 ) 1 B 20,000 (6 ) 1 B 20,000 (6 ) 1 A 20,000 (6 ) 1 A 20,000 (6 ) 1 A 20,000 (6 ) 1 A 20,000 (6 ) 12 /JEMA 300 A B IDF100F150F-W 6 8
V (2) Analog Output 2 Analog output signal 2 CH2 circulating fluid temperature 0C100C: 010 V 1 CH2 electric conductivity 0.150.0 S/cm: 0.0210.0 V 2: In the case of option D1 "CH1 with electrical conductivity control".
or less 48 V 100 V 0 0.6 0.5 0.4 0.3 0.2 0.1 Max. operating current and range 50 mA 40 mA 20 mA Set pressure scale (MPa) Impact resistance 30 G Environmental resistance Enclosure IP40 Electric Circuit To 100 VAC/VDC Reed switch 736 Compact Manifold Regulator ARM11A/B Series DIN Rail When only DIN rail is required: DIN rail part no.
Example: Analog output = 1 to 5 [V] F.S. = 5 [V] 1 [V] = 4 [V] 3 [% F.S.] = 4 x 0.03 = 0.12 [V] The output error induced by the temperature change can be as much as 0.12 [V].
OUT1 OUT2 With panel mount adapter (For without flow adjustment valve) With panel mount adapter (For with flow adjustment valve) A B C D NPN PNP NPN NPN PNP PNP NPN PNP NPN PNP ZS-33-J ZS-33-JS Panel mount Panel mount adapter A adapter A Analog 1 to 5 V Panel mount Analog 4 to 20 mA Panel mount adapter B E Analog 1 to 5 V adapter B F Analog 4 to 20 mA External input Note) G H External input
I$ODEL NO. 2 , 1 3 (s4) S P & S P A 0 1 1 3 43 y. qB siB s/B s/g 9a SP & SPA 0114 54 B B B B sP & sPA 0115 45 S s 2 MTNG HOLES I .FOOTPRINT' CLASS 1 SUB.PLATE MOUNTED 'SWAY VATVES '49 i.'8 (?
I$ODEL NO. 2 , 1 3 (s4) S P & S P A 0 1 1 3 43 y. qB siB s/B s/g 9a SP & SPA 0114 54 B B B B sP & sPA 0115 45 S s I 2 MTNG HOLES .FOOTPRINT' CLASS 1 SUB.PLATE MOUNTED 'SWAY VATVES '49 i.'8 (?
The combinations of detection shown above may be limited when gripping of the work piece is performed at the end of the opening/closing stroke of the fingers due to hysteresis of the auto switch. 17 Series MRHQ Rotary Gripper Solid State Switch/Direct Mounting Type D-F9N (V), DF9P (V), D-F9B (V) Auto Switch Specifications D-F9, D-F9V (with indicator light ) D-F9P D-F9NV D-F9PV Perpendicular
L1 L2+A5 L3 2 1 W V 2 E= ( ) 2 9.8 1000 Collision speed V=1.4 Va *) Corrected coeficient 1 10 420 E= ( ) =0.09 2 9.8 1000 V=1.4 x 300=420 Calculate kinetic energy E(J) of moment. Calculate allwable kinetic energy Ea(J). Check that kinetic energy of moment does not exceed allowable kinetic energy.
(B contact) 3 wire GXL-N12FTB Switch specifications (SUNX Corporation) GXL-N12FT(B) Part no.
RB 5 V, 12 V IC circuit 3-wire (PNP) Grommet 2-wire 12 V J Connector 3-wire (NPN) Relay, PLC 24 V IC circuit 5 V, 12 V Diagnostic indication (2-color indication) D3-wire (PNP) Grommet 12 V Water resistant (2-color indication) 2-wire -X With diagnostic output (2-color indication) 4-wire (NPN) 5 V, 12 V IC circuit 20Lead wire length symbols: 0.5 mNil (Example) A73C 3 m L (Example) A73CZ