When a load, such as a relay or solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element. 8.
Error code = "01h" Calculated 8 value Checksum(LRC) 9 Calculated value 10 End code CR 11 LF 22 - (4) 05h Write (force) a single output signal Function code used to write (force) a single Y contact (output signal) to either ON or OFF.
Model AS1ll1FS-M5l AS2ll1FS-01 AS2ll1FS-02 AS3ll1FS AS4ll1FS Metric size 2 3.2 4 6 3.2 4 6 8 10 3.2 4 6 8 10 6 8 10 12 10 12 16 Tubing O.D.
-20 . 8-6 8.4 Cooling Capacity . 8-7 8.4.1 HRL100-A-20 CH1 . 8-7 8.4.2 HRL200-A-20 CH1 . 8-7 8.4.3 HRL300-A-20 CH1 . 8-8 8.4.4 HRL100/200/300-A-20 CH2 . 8-8 8.5 Pump Capacity . 8-9 8.5.1 HRL100-A-20 CH1 . 8-9 8.5.2 HRL200-A-20 CH1 . 8-9 8.5.3 HRL300A20 CH1 . 8-10 8.5.4 HRL-A-20CH2 . 8-10 8.6 Types of Hazard Labels . 8-11 8.6.1 Positions of danger warning label . 8-12 8.7 Standards . 8-13
B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 1-A 1-B 1-C 2-A 2-B 2-B 2-B 2-B 2-B 2-B Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 6 1/8, 1/4 500 1.5 0 1,000 2,000 3,000 6 1/4, 3/8 10 1/4, 3/8 10 1/4, 3/8 10 1/4, 3/8 10 1/4, 3/8 6 1/4, 3/8 8 1/4, 3/8 10 1/4, 3/8 10 1/4 Maximum
If an impact load is applied to the spline rod, the guide unit may be permanently deformed and displacement may increase. 0 10 20 30 Lateral load (N) 8-10-10 10 Precision Cylinder Series MTS 8, 12, 16, 20, 25, 32, 40 How to Order MX Piping direction MTS Bore size Standard piping type Axial piping type Nil P 8 8 mm MY MTS 8 F9BW 20 8 CY MG Courtesy of Steven Engineering, Inc.-230 Ryan Way,
1/2 10 14 10 14 10 14 19.4 23.8 19.4 23.8 20.9 25.3 23.3 26.7 28.1 29.7 30.1 33.5 29.7 30.1 33.5 31.3 31.7 35.1 31.3 31.7 35.1 33.1 36.3 16.3 19.1 16.3 19.1 17.8 20.6 20.2 22 23 8 14 8 14 10 16 18 24 36 34 41 67 33 40 66 33 40 66 30 38 63 51 67 4 2.5 1.8 1.6 d 8 5 KQB2 Applicable tubing 4 3 2.3 2.6 H1 H2 KS KX 6 4 3.3 6 10 5.8 M A L KM 14 8 6 14 6.6 5.3 17 Connection thread 17 KF 17 25 10
U U V 10, 3/8", 12 91 (97) 22.5 30 45 20 6 13.5 41.5 25 33 58.5 (64.5) 27 45 (50.5) 30 50.5 (56) 3 A VXD2 64.5 52.5 Model Mounting bracket dimensions One-touch fitting P a b d e f 10, 3/8", 12 3 A 58 65 67 52 25.5 VXD2 ( ): Denotes the Normally Open (N.O.) dimensions. 138 Pilot Operated 2 Port Solenoid Valve VXD Series Air Air 3 A Dimensions/VXD2 Body Material: Resin (10, 3/8", 12) Conduit
space 100mm or more) Option: P Port size L A B C D E Model F G J H K 97 224 8 119 [126] 5/16 114 249 10 147 [154] 3/8 83 187 53 165 62 113 212 54 190 82 IDG10, IDG10H IDG20, IDG20H Values inside [ ] are for NPT threads 1/4, 3/8 15 Membrane Air Dryer Series IDG Dimensions (mm) 1in = 25.4mm IDG30, 50 IDG30H, 50H IDG30L, 50L With fittings for purge air discharge (Option: P) Port size L Purge
750 kPa 750 kPa 1 0 0 2 4 6 8 10 12 14 Number of needle rotations Number of needle rotations Number of needle rotations PF2M711(-L) PF2M721(-L) 100 L/min 200 L/min PF2M750(-L) 50 L/min 120 100 80 60 40 20 0 0 2 4 6 8 10 12 14 240 200 160 120 80 40 0 0 2 4 6 8 10 12 14 60 50 40 30 20 10 0 0 2 4 6 8 10 12 14 750 kPa 350 kPa 150 kPa 350 kPa 150 kPa 350 kPa Flow [L/min] Flow [L/min] Flow [L/
With auto switch Without auto switch B A B D Stroke range Bore size (mm) BP C E F G H I J K L M N Q O OA OB P RA RB S T U V Z A 82 36 10 to 50 Rc 1/8 15.6 14 Rc 1/4 63 16.5 46 92 8 1.6 15 20 38 M10 x 1.5 103 17 60 M8 x 1.25 53 16 4.2 47.5 19 93 7 9 10.5 77 92 46 depth 12 depth 10.5 75, 100 96.5 43.5 10 to 50 19.6 17.5 Rc 3/8 Rc 1/4 80 106.5 53.5 18.5 10 2 21 25 43 M16 x 2.0 132 22 77 M10
Type Applicable tube outside diameter Metric size Inch size 2 3 Elbow Universal 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 03 05 07 09 11 13 3.2 4 6 8 10 12 23 04 06 08 10 12 Control method 0 1 Meter-out Meter-in With One-touch fittings Use a 1/8" tube.
range Actuation range A B Rotation range m 190 40 10 20 10 1 2 3 7 20.9 22.8 24.4 28.7 16.9 18.8 20.4 24.7 A A 190 35 10 20 10 190 30 10 15 10 When D-F9 is used 190 25 10 15 10 Rotation range m: Value of the operating range Lm of a single auto switch converted to an axial rotation angle.
7.4.1 Replacing Particle Filters . 7-8 7.4.2 Replacing the DI filter . 7-8 7.4.3 Consumables . 7-10 Chapter 8 Documents . 8-1 8.1 Specifications . 8-1 8.1.1 HRL100/200/300-A-20 . 8-1 8.1.2 Refrigerant with GWP reference. 8-2 8.1.3 Communication specifications . 8-2 8.2 Dimensions . 8-3 8.2.1 HRL100-A-20 . 8-3 8.2.2 HRL200-A-20 . 8-4 8.2.3 HRL300-A-20 . 8-5 8.3 Flow Diagram . 8-6 8.3.1 HRL-A
Model AS1ll1FSGl-M5 AS2ll1FSGl-01 AS2ll1FSGl-02 AS3ll1FSGl AS4ll1FSGl Metric size 2 3.2 4 6 3.2 4 6 8 10 3.2 4 6 8 10 6 8 10 12 10 12 16 Tubing O.D.
(n = 4, 8, 12, 16) Note 4) 135 + 50 (n 4) 2 110 + 50 (n = 4, 8, 12, 16) Note 4) Different surfaces (n = 4, 8, 12, 16) Note 4) n 75 + 50 (n 2) (n = 2, 3, 4) 90 + 50 (n 2) (n = 2, 4, 6, 8) Note 3) 115 + 50 (n 2) (n = 2, 4, 6, 8) Note 3) 125 + 50 (n 2) (n = 2, 4, 6, 8) Note 3) 135 + 50 (n 2) (n = 2, 4, 6, 8) Note 3) 145 + 50 (n 2) (n = 2, 4, 6, 8) Note 3) same surface 10 20 75 145 115
Model A L D KQ2P-04 KQ2P-06 KQ2P-08 4 6 32 16 6 8 35 18 8 10 39 20.5 A A A A A B B 5 Series SZ3000 DIN rail dimension table/weight table D-sub connector (25 pins)/cable assembly VZ1000-11-11 VVZS3000-21A~ 3 Refer to the L dimension table Enter a number from the DIN rail dimension table below in the .
8 6 D-M9 D-M9W 4 5 4 4 D-C7/C80 D-C73C/C80C 8 9 10 10 D-B5/B64 D-B59W 8 9 10 10 13 14 14 13 D-H7/H7W D-H7NF/H7BAL 4 4.5 5 4 D-H7C D-A3/D-A44 D-G39/D-K39 D-G5NTL D-G5NBL 7 9 10 8.5 9 9 10 10 Since this is a guideline including hysteresis, not meant to be guaranteed.
8 6 D-M9 D-M9W 4 5 4 4 D-C7/C80 D-C73C/C80C 8 9 10 10 D-B5/B64 D-B59W 8 9 10 10 13 14 14 13 D-H7/H7W D-H7NF/H7BAL 4 4.5 5 4 D-H7C D-A3/D-A44 D-G39/D-K39 D-G5NTL D-G5NBL 7 9 10 8.5 9 9 10 10 Since this is a guideline including hysteresis, not meant to be guaranteed.
Connector C Actuator side (Terminal no.) 1 2 5 6 (14) (18) 8 A1 B1 (13.5) (17.7) (17.7) Cable length (L) 1 3 5 8 A B C 1 2 A6 B6 1.5 m 3 m 5 m 8 m (30.7) Connector A 5 6 (14.7) Connector D L (11) (10) 8 A B C LE-CP/Cable length: 8 m, 10 m, 15 m, 20 m ( Produced upon receipt of order) Controller side 10 m (14.2) Connector C (Terminal no.) 1 2 5 6 15 m 5.5 6.3 Actuator side (14) (18) (Terminal