SMC Corporation of America
Elite Part Number Search
Search Results "10-CDM2XL32-250-M9BS"

130 120 MXF12 360 250 210 MXF16 690 500 360 MXF20 1370 1060 750 600 D-X Individual -X 137

13 8 45 6 8 33.5 5.5 15 30 M26 x 1.5 1/8 62 120 M10 x 1.25 26 22 19.5 17 32 12 13 8 45 6 8 37.5 5.5 15 34.5 M26 x 1.5 1/8 64 122 M10 x 1.25 26 24 21 22 41 14 16 11 50 8 10 46.5 7 21.5 42.5 M32 x 2 1/4 88 154 32 M14 x 1.5 (mm) Boss-cut ZZ Bore size (mm) 20 25 32 40 103 107 109 138 10

Graph 1 30 20 10 5 4 3 1600st 1400st 1200st 1000st 800st 600st 500st 400st 300st Load movement time: t(S) 2 1 Example) 200st 0.5 0.4 0.3 100st 0.2 280 V' 0.1 100 200 300 400 500 Maximum speed: V(mm/s) V W Step 2 Find the cylinder bore size.

Lock keys (refer to P9) Minimum pressure (F_1) adjusting range Maximum pressure (F_2) adjusting range 120% 100% 100% 90% 10% 0% 0% 4 0 0 0 12 10 20mA 20mA 4 0 0 0 12 10 20mA 20mA 2.5 5V 2.5 5V 5 10V 5 10V (Note1) F_1 is adjustable in a range from 0% to 90% of the rated value. (Default value : 0%0.00MPa) (Note2) F_2 is adjustable in a range from 10 to 120% of the rated value.

Lock keys ( ref er t o P11) M i ni m um pressure ( F_1) adj ust i ng range M axi m um pressure ( F_2) adj ust i ng range 100% 100% 50% 0% 10% 0% 20m A 20m A 5V 10V 20m A 20m A 5V 10V 4 0 0 0 12 10 2. 5 5 4 0 0 0 12 10 2. 5 5 ( N ot e 1) : F_1 i s adj ust abl e i n a range f rom 0 t o 50% of t he rat ed val ue. ( N ot e 2) : F_2 i s adj ust abl e i n a range f rom 10 t o 100% of t he rat ed

Lock keys ( ref er t o P11) M i ni m um pressure ( F_1) adj ust i ng range M axi m um pressure ( F_2) adj ust i ng range 100% 100% 50% 0% 10% 0% 20m A 20m A 5V 10V 20m A 20m A 5V 10V 4 0 0 0 12 10 2. 5 5 4 0 0 0 12 10 2. 5 5 ( N ot e 1) : F_1 i s adj ust abl e i n a range f rom 0 t o 50% of t he rat ed val ue. ( N ot e 2) : F_2 i s adj ust abl e i n a range f rom 10 t o 100% of t he rat ed

Description of the model EXW1-NT1 (NFC Reader/ Writer) Applicable models Wireless System EXW1 series Wireless System EX600-W series Corresponding card ISO 14443 compliant, Type B Interface USB2.0 Full speed (12Mbps) * USB3.0, operable with 1.1 Power supply USB bus power Voltage 5 V Power consumption Maximum 250 mA Dimension [mm] 72 (L) 24 (W) 10 (H) Weight Approx. 12.5 g Operating temperature

Conductance l/s Note 2 5 14 45 80 160 200 Internal 1.3 x 10-10 for the standard material (FKM) at ambient temperatures , excluding gas permeation Leakage Pa m3/s External 1.3 x 10-11 for the standard material (FKM) at ambient temperatures , excluding gas permeation Flange type XMC KF(NW),CF KF(NW) KF(NW),CF KF(NW) KF(NW),K(DN) ,CF KF(NW),K(D N) XYC KF(NW) KF(NW) KF(NW) KF(NW) K(DN) KF(NW

Specifications 20 25 32 40 Bore size (mm) Action Double acting/Single rod Low friction direction One direction Fluid Air Proof pressure 1.05MPa Max. operating pressure 0.7MPa Min. operating pressure 0.025MPa Without auto switch: 10 to +70C (No freezing) Ambient and fluid temperature With auto switch: 10 to +60C (No freezing) Integrated clevis style 0.5 l/min (ANR) or less Allowable leakage

G PPA AL 14-12-3 4 Compact Manometer Series PPA PPA100/101/102 How to Order Unit specifications PPA10 0 M Pressure specifications Nil M Option/Case holder With the unit switching function(1) 0.1 to 1 MPa (For high pressure) 101 to 10 kPa (For vacuum) 10 to 100 kPa (For low pressure) 0 1 2 Fixed in SI unit (2) None With PPA-B Nil B Note 1) With unit switching function is not permitted to sell

G PPA AL 14-12-3 4 Compact Manometer Series PPA PPA100/101/102 How to Order Unit specifications PPA10 0 M Pressure specifications Nil M Option/Case holder With the unit switching function(1) 0.1 to 1 MPa (For high pressure) 101 to 10 kPa (For vacuum) 10 to 100 kPa (For low pressure) 0 1 2 Fixed in SI unit (2) None With PPA-B Nil B Note 1) With unit switching function is not permitted to sell

.: Uni-wire H System DeviceNet CC-Link Applicable system Protocol Communication specification Output specification Environmental resistance Release 2.0 Ver. 1.10 Version Note 1) 156 k/625 kbps 2.5 M/5 M/10 Mbps 750 kbps 28.5 kbps Communication speed 125 k/250 k/500 kbps 28.5 kbps 29.4 kbps Specified file Note 2) EDS file 32/32 (1 station, remote I/O stations) Occupied area (Number of inputs

-2No.PS-OMF0005CN-E / 1 1.5 *3) 1 1 [] -3No.PS-OMF0005CN-E () () -4No.PS-OMF0005CN-E () * 5 m -5No.PS-OMF0005CN-E * (RcNPTG) 1/8 79 Nm 1/4 1214 Nm 1.52 2 * () ()() () () -6No.PS-OMF0005CN-E * IP66IP65 () 060 (5 ) * -7No.PS-OMF0005CN-E (ISA2 ) * * (EXH) 5 m 0.2 MPa CE (2 VCA ) () C-R () ()C-R ( ) () AC 10 DC 2 * * 2 0.51.25 mm -10+10 5 -8No.PS-OMF0005CN-E *

Ambient temperature for operation: -10 to 50 Ambient temperature for storage: -20 to 60 Pollution degree 2: (UL508) Switch No. No.4 No.3 125 kbps 0 0 1 0 250 kbps Communication speed 0 1 500 kbps Caution 1 1 After maintenance is complete, perform appropriate functional inspections. Stop operation if the equipment does not function properly.

The voltage variation must stay within the -10 to +10% range of the rated voltage.

) 10% or less (With power supply polarity protection) 55 mA or less (at no load) NPN or PNP open collector output: 1 output 80 mA 30 V (With NPN output) 1 V or less (With load current of 80 mA) 1 s (0.25, 0.5, 2, 3) Yes 1% F.S.

10% or less (With power supply polarity protection) 55 mA or less (at no load) NPN or PNP open collector output: 1 output 80 mA 30 V (With NPN output) 1 V or less (With load current of 80 mA) 1 s (0.25, 0.5, 2, 3) Yes 1% F.S.

10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?

10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?

10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?