SMC Corporation of America
Elite Part Number Search
Search Results "VR1220F-11"

M L1 L2 1 4 8 6 DEF06-02 48 20 11 16 16 50.5 46.5 17 15 13 11 19 17 14 12 14 12 6max. 4max. 3 8 DEF08-03 66 3 8 3 8 DEF10-03 10 12 53.5 89 DEF12-03 54.5 34 51 17 17 17 17 15 17 19 19 104 17 19 17 19 7max. 7max. 105 Series H, DL, L, LL Self-align Fittings Plug: DP Applicable tube O.D. Weight (g) Part No.

Description Side cover Bearing retainer Bumper End cover A End cover B Inner cover Motor cover R Motor cover L Auto switch Magnet Brake Material Note 100W Ball screw/Slide screw 1 2 3 4 5 6 7 8 9 10 11 No.

Heat treatment 1 Stainless steel Body Heat treatment 2 Stainless steel Table 7 1 2 8 9 6 13 12 11 3 Resin Cover 4 Resin Return guide 5 Scraper Electroless nickel plated 6 Brass Piston Electroless nickel plated 7 Carbon steel Joint shaft Electroless nickel plated 8 Brass End cap 9 Polyurethane Rod bumper 10 Steel ball High carbon chrome bearing steel Electroless nickel plated 11 Plug Brass

W M L H E W M 10 14 18 22 30 36 14 20 25 29 37 49 46.5 57 79 88 103 122 11 16 21 24 32 41 10 17 22.5 24.5 27 30 1/8" 1/4" 3/8" 1/2" 3/4" 1" LQ3U1A LQ3U2A LQ3U3A LQ3U4A LQ3U5A LQ3U6A 1/4 (E) (E) L

Piping 10 7.1 Piping connections to the PD Ports 10 7.2 Piping connections to the Supply (P) port 11 8. Construction 12 9. Dimensions 15 10.

Tubing size Symbol 03 04 03 04 05 06 07 06 08 10 07 11 10 12 11 13 12 13 19 Body class Tubing O.D. 1/8", 3 4 1/8" 4 3/16" 6 1/4" 6 8 10 1/4" 3/8" 10 12 3/8" 1/2" 12 1/2" 3/4", 19 Body class 1 Symbol 1 2 3 4 5 Body class 1 2 3 4 5 Type of part Symbol U B N Type of part Nut & Insert bushing Insert bushing Nut 2 3 4 5 505 Applicable Fluids Material and fluid compatibility check list for High

Figure 11-1 MPC Group Power Connections The diagram illustrates the Ethernet communication and power cable connections required to support 21 MPCs when daisy chaining is in use. The MPCs in the dashed box form a single Power daisy chain group. Note that power daisy chaining supports a maximum of 20 MPCs in one power group.

Mounting Wiring/Piping Caution Warning 11. Transition wiring of ionizer For transition wiring of ionizers, use a transition wiring cable for connection between ionizers. Use a power supply cable for connection between ionizer and power supply or external equipment. (Transition wiring is not possible with the IZS40.)

13 90 3.2 1 3.2 43.3 1/8 44.5 95 4.5 129.6 44 46 80.3 70 43.3 66 65.8 11 13 90 3.2 Note 1) The dimension of B is the length when the filter regulator knob is unlocked.

(Mounting hole) (12) 24.9 43.85 L (Lead wire length) 153.4 3 x 1/4" {1(P), 3(EB), 5(EA) port} 56.3 23 0.5 0.5 EB 3 P 1 EA 5 49.8 02 03 L-type plug connector with cover (LL) 53-SY9120-LLInsulator: Red (+) Insulator: Black () 4.1 16.7 0.3 mm2 L (Lead wire length) 148.3 02 03 Terminal type (TT) 53-SY9120-TTLead wire marking No. 1 (+), No. 2 () 14 0.75 mm2 L (Lead wire length) 165.1 Max. 10 11

Indicator Switch (Option) Specification Wiring Diagram ISH NPN 3.8 to 30 VDC Max. 0.4 VDC Max. 11 mA Max. 20 mA AWG 24 3 m Blue (BL), Brown (BN), Black (BK) Code Output type Power supply voltage Output voltage Supply current Output current BN + BL Indicator switch Load BK Lead wire Cable length Color (Lead wire) Cable 1082 Diaphragm Valve for Ultra High Purity Manually operated type (For

NTJ-015A NT-02 NT-04 NT-05 12 M5 x 0.8 4 8 9.2 7.8 H B 20 M8 x 1.25 5 13 15.0 12.5 32 . 40 M14 x 1.5 8 22 25.4 21.0 50 . 63 M18 x 1.5 11 27 31.2 26 Electrical Wiring Output type The output signal of the stroke reading cylinder is A/B phase difference output (open collector output) as shown in the figure below.

Symbol Bore size (mm) A A' B B' D E F GA GB H MM NN R X Y LC LH LT LX LZ 6 10 15 M3 x 0.5 17 6 28 6 20 8 10.5 1.6 3 11 14 3.4 14 6.5 10.5 9 M10 x 1.0 7 7 M4 x 0.7 20 7 33 6 24 8 13 1.6 5 13 17 4.5 15 7 12 12 M12 x 1.0 8 10 M5 x 0.8 24 7 43 6 30 10 15.5 2.3 6 18 19 5.5 20 16.5 14 M14 x 1.0 10 12 10 Symbol S Z With auto switch Bore size (mm) W J 5 st 10 st 15 st 20 st 30 st 5 st 10 st 15 st

Refer to the above drawing for DIN terminal dimensions. n L 1 50 27 2 69 46 3 88 65 4 107 84 5 126 103 6 145 122 7 164 141 8 183 160 9 202 179 10 221 198 11 240 217 12 259 236 13 278 255 14 297 274 15 316 293 16 335 312 17 354 331 18 373 350 19 392 369 20 411 388 L1 L2 1428 VK3000 Series Specific Product Precautions Be sure to read this before handling the products.

When attaching an extension nozzle cover, confirm that the nozzle tip is completely inserted into the extension nozzle cover. 11. Do not use a nozzle cover or extension nozzle cover if it is cracked or does not fit securely, and replace with a new cover. 7 8 9 10 These safety instructions are intended to prevent hazardous situations and/or equipment damage.

Service life cycles (10 thousand) Operating pressure (Pa) Leakage (Pam3/s) Effective area (mm2) Model Valve type Piping size Orifice (mm) Internal External Fitting P.523 For VCR 1.3 x 10-11 XVD2-02V 50 0.2 MPa (G) to 1 x 10-6 5 x 10-9 1.3 x 10-11 Single acting (N.C.) 1/4 3 Main air supply: 4.6 Initial air supply: 0.2 to 4.6 Values at normal temperature, excluding gas permeation to For Swagelok

2 ZFB101-05 ZFB101-07 ZFB201-07 ZFB301-11 ZFB401-13 65 54 53 27.2 24.2 24 19.7 17.7 17.5 " " 15.2 18.5 21.7 14.4 15.5 50 15 12.5 22.5 26 48 12.8 8.5 52 57 64.5 28 30 34 9.5 11 13.5 24.5 27 30.5 13.5 14.5 16.5 16 17 21.5 61 65 81 17.5 21.5 25.6 16.6 18 23 70 87.5 30.2 34 21.7 24 280

Applicable cylinder ML2B25 ML2B32 ML2B40 MY-S25A M6 x 1 35 50 8 5 9.5 5.5 B MY-S32A M8 x 1.25 45 64 11.7 6 11 6.6 B Guide for Side Support Application For long stroke operation, the cylinder tube may be deflected depending on its own weight and the load weight. In such a case, use a side support in the middle section.