 
Sink Circuit Source Circuit 24 V 24 V + DRIVER input + DRIVER input Input Signal Polarities Input Signal Polarities Level Voltage Level Voltage Signal Contact Signal Contact Level Level ON Low (L) ON High (H) 0 V Close 24 V Close level level OFF High (H) OFF Low (L) 24 V Open 0 V Open level level 14 - 2.3.3 Sequence Input Circuit Incorrect wiring or incorrect voltage application to the
If the adjusting screw of the speed controller is loosened, the operating speed will increase, so the screw should be tightened completely. m Impact force MXZ12 MXZ16 1.4 2.5 V = mm/s V = mm/s 1.2 2.0 Load weight m [kg] Load weight m [kg] 1.0 1.5 0.8 0.6 1.0 V = 50 V = 50 0.4 V = 100 V = 100 V = 200 V = 200 0.5 V = 500 V = 500 0.2 0.0 0.0 60 50 40 30 20 10 0 0 5 20 15 10 25 30 35 40 45 50
Plug: Without check valve Socket: Without check valve KKA4S-02M-1 KKA4P-02M-1 40.2 KKA KKA KKA6S-04M-1 KKA6P-04M-1 76.0 KP How to Order LQ KKA 4 P M 02 MQR Built-in check valve Body size With check valve Nil -1 Socket/Plug designation 1/8 1/4 1/2 3/4 1 1 1/4 3 4 6 7 8 9 T Without check valve P S Plug Socket Note) KKA7/8/9 is not available without a check valve.
ZP3P-20PTSF ZP3P-25PTSF ZP3P-35PTSF ZP3P-50PTSF p. 2 q Pad unit With Buffer p.6 e Buffer assembly Pad diameter Part no. 20 25 35 50 Dimensions ZPB2(J/K)10-B5 V V ZPB2(J/K)20-B5 V V ZPB3(J/K)10-B01 V V ZPB3(J/K)20-B01 V V p. 12 e Buffer assembly w T female thread adapter Pad diameter Part no. 20 25 35 50 Dimensions ZP3PA-T1-B5 V V ZP3PA-T2-B8 V V w T female thread adapter p. 11
Analogue output 1 to 5 V Output impedance 1 K Max.28 V, 80 mA Internal voltage drop 1 V max.
Sink Circuit Source Circuit 24 V 24 V + DRIVER input + DRIVER input Input Signal Polarities Input Signal Polarities Level Voltage Level Voltage Signal Contact Signal Contact Level Level ON Low (L) ON High (H) 0 V Close 24 V Close level level OFF High (H) OFF Low (L) 24 V Open 0 V Open level level 14 - 2.3.3 Sequence Output Circuit Incorrect wiring or incorrect voltage application to the
Start-up . 6 3.1 Preparation . 6 (1) Software installation . 6 (2) Installation and wiring . 6 3.2. Start-up . 6 (1) Supply of power . 6 (2) Start-up of the Controller setting software . 6 (3) Alarm check . 8 4.
state switch Yes Yes 100 V 12 V Relay, PLC 24 V 2-wire Connector 12 V Diagnostic indication (2-color indication) Grommet A79W 3-wire (NPN) 3-wire (PNP) F79 F7P J79 F79W F7PW J79W F7BA M9NV M9PV M9BV F9NWV F9PWV F9BWV M9N M9P M9B F9NW F9PW F9BW F9BA F7NV F7PV F7BV J79C F7NWV F7BWV F7BAV IC circuit 5 V, 12 V Grommet 2-wire 12 V Connector 3-wire (NPN) 3-wire (PNP) IC circuit
6 DC () Blue D-F9V Mounting screw M2.5 x 4l D-F9B, F9BV 4.3 Slotted set screw Indicator light 2 OUT (+) Brown Main switch circuit 20 2.7 2.8 4.6 OUT () Blue 3.8 3.1 6.2 4 Most sensitive position 6 18 2-Color Display Solid State Switches/Direct Mount Type D-F9NW(V), D-F9PW(V), D-F9BW(V) Auto Switch Specifications Grommet D-F9W, D-F9WV (with Indicator light) Auto switch part no.
THR THS1,2 TB1,2 FM1,2 V SWL SW L PRR PRS1 PRS2 PRS3 PLC HM GFCI EDV IDF100150F 6-4 6 5 IDX-OM-U021 6 IDF150F-30R () CM OLR MC1,2 THR THS1,2,3 V TB1,2 FM1,2,3 SWL SW L PRR PRS1 PRS2 PRS3 PLC HM GFCI EDV IDF100150F 6-4 6 6 IDX-OM-U021 6 6-5 ,, IDF100150F 6-5 6 7 IDX-OM-U021 6 6-6 () (1) IDF-FL219 (IDF100F,125F ) 1 IDF-FL220 (IDF150F ) 1 ADH-E400
O-ring Seal Seal 6 7 8 9 10 11 12 Zinc die-casted, NBR 126115AP GA46-10-01 AF11-3 126140 11307 126115AP GA46-10-02 AF11-3 126060 11307 126046 126047 Maintenance Warning NBR NBR NBR NBR 1. Before removing the oil filler plug, loosen it two and a half turns to completely release the pressure inside the case.
-40-W) AWG26 0.51 mm 1.00 mm 3.5 mm -68No.PF-OMN0011CN-C / (PF3W704/720740) A B C 1 V 1.5 V 5 V 4 mA 6 mA 20 mA (PF3W711) A B C 1 V 1.4 V 5 V 4 mA 5.6 mA 20 mA (PF3W721) A B C 1 V 1.5 V 5 V 4 mA 5.9 mA 20 mA [L/min] PF3W504 0.5 4 PF3W520 2 16 PF3W540 5 40 PF3W511 10 100 PF3W521 30 250 -69No.PF-OMN0011CN-C / A B C D 0.6 V 1 V 5 V 5.4 V 2.4 mA 4 mA 20 mA 21.6 mA -70No.PF-OMN0011CN-C
[%F.S.] 2.0 1.5 1.0 0.5 0.0 0 1 2 3 4 5 [s] [S] [MPa] [MPa] [MPa] [MPa] [ [ [ [ ] ] ] ] 2 69 No.LFE*-OMY0008 / / / / A B C 1 V 1.1 V 5 V 4 mA 4.4 mA 20 mA [L/min] LFE1 0.5 20 LFE2 2.5 100 LFE3 5 200 70 No.LFE*-OMY0008 2x )M12 () 1.6mm A B C D E F G H I J K L LFE13 3/8 90 73 40 23.5 56 83 89 24 6 1.6 96 87 LFE14 1/2 104 73 40 23.5 56 83 89 28 6 1.6 96 87 LFE26 3/4 105 78 50 29 67
This may cause damage to the machinery. ) m m ( e z i s e r o B e v l a v n o i h s u C s t a l f s s o r c a h t d i W h c n e r w n o g a x e H 0 5 , 0 5 , 2 3 7 4 2 1 C 0 1 2 3 B M 5 . 2 5 . 2 y e k h c n e r w n o g a x e H 0 0 1 , 0 8 , 3 6 0 5 2 1 C 0 1 3 6 B M 4 4 y e k h c n e r w n o g a x e H Mounting & Piping 2. Be certain to activate the air cushion at the stroke end.
T Slightly flexible 1.0 MPa max. at 20C Black Blue White Soft Nylon Tubing Series TS 15-6-8 15-6-9 15-6-3 15-6-4 15-6-5 Yellow Flame resistant (Equivalent to UL-94 standard, material V-0) Red Green VMG Blue Yellow FR Double Layer Polyurethane Tubing Series TRBU Green Black White 15-6-21 15-6-13 15-6-15 15-6-22 Red Blue Flexible 0.8 MPa max. at 20C Black Flame resistant (Equivalent to UL-94
12 V IC circuit Reed auto switch Solid state auto switch 12 V Diagnostic indication (2-color display) 5 V,12 V IC circuit Relay, PLC Grommet 24 V Yes 12 V 5 V,12 V IC circuit Water-resistant (2-color display) M9PAV1 M9BAV1 12 V Magnetic field resistant (2-color display) 2-wire (Non-polar) 3-wire (NPN equivalent) A96V A96 5 V IC circuit Yes 24 V Grommet A93V2 A90V A93 A90 12 V 5
12 V 12 V IC circuit 5 V, 12 V Relay, PLC Diagnostic indication (2-color indicator) Yes Grommet 24 V 12 V IC circuit 5 V, 12 V Water resistant (2-color indicator) M9PAV1 M9PA1 M9BAV1 M9BA1 12 V 3-wire (NPN equivalent) Grommet 24 V A96V A96 IC circuit 5 V Yes A93V2 A93 A90 IC circuit 100 V Relay, PLC 2-wire 12 V A90V No 100 V or less 1 Water resistant type auto switches can be mounted
45 50 5 6 6 8 8 8 8 10 21 25 25 27 149 153 155 191 The bracket is shipped together.
(g) Connection thread D L1 L2 Q KEC-02 KEC-03 665
D L2 L3 L4 L5 L6 L7 L8 P d h T L1 Model Model ASS10 ASS100 ASS110 2 10 5 20 9 5 20 52 14 4 17 50 XT14-82-3-1 1 8 ASS30 ASS300 ASS310 3.2 12 6 30 12 6 26 73 23 5 16.5 63 XT14-105-5-1 1 4 3 8 , ASS500 ASS500 2.3 14 7 35 13 6 38 99 27 6 30.5 90 XT14-89-2-1 1 2 3 4 , ASS600 ASS600 3.2 14 7 65 14 6 46 116 31 6 26 112 XT14-85-2-1 3 4 1 , AS Meter-in Control Type Meter-out Control Type ASP Mounting