SMC Corporation of America
Elite Part Number Search
Search Results "SYJ3323-6LOZ-M3"

Mounting screw (M3 x 5 L) Function selection mode Panel mount adapter (can be rotated 90 degrees for mounting). Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result. This product is not designed to be explosion proof. Troubleshooting Wiring Wiring of connector Connections should only be made with the power supply turned off.

Mounting by panel mount adapter Fix the panel mount adapter to the controller by the mounting screws M3 x 8 L (2 pcs.).

2 VN*-OMJ0001-B / / / / 1 1 1 1 1 1 1 1.5 .5 .5 .5 *3) *3) *3) *3) 1 1 1 1 1 1 1 1 () 3 VN*-OMJ0001-B 1)-5 2) ( ( ( ( ) ) ) ) () IP IP IP IP65 65 65 65 1) 50mm 2/s 2) 3) 1) 2) 5m 3) 4) 1.5~2 2 4 VN*-OMJ0001-B 3)0.1MPa Nm Rc1/8 79 Rc1/4 1214 Rc3/8 2224 Rc1/2 2830 Rc3/4 2830 Rc1 3638 Rc1 1/4 4042 Rc1 1/2 4850 Rc2 4850 ( ( ( ( 5, 6, 7 5, 6, 7 5, 6, 7 5, 6, 7 ) ) ) ) G1/2 M3

Table 3-5 Signal cable Terminal specification Cable specification Terminal block Recommended screw diameter crimp terminal M3 1.25Y3 0.75 mm2 (AWG18) Shielded cable 3.3 Installation HRS Series 3-18 HRX-OM-S004 Chapter 3 Transport and Setting Up 3.3.5 Wiring of run/stop signal inputRemote signal input Run/Stop signal input and remote signal input enable the product to operate/stop or switched

HRSH Series 3.2 Installation 3-7 HRX-OM-Q026 Chapter 3 Transport and Setting Up Table 3-2 Amount of radiation and required ventilation Required ventilation amount (m3/min) Heat Differential temp. of 3 oC between inside Differential temp. of 6 oC between inside Model radiation (kW) and outside of and outside of installation area installation area HRSH100-A-20/40Approx.18 305 155 HRSH150-A-

Table 3-2 Amount of radiation and required ventilation Required ventilation amount (m3/min) Heat Differential temp. of 3 oC between inside Differential temp. of 6 oC between inside Model radiation (kW) and outside of and outside of installation area installation area HRS200-A-46-S Approx.37 615 310 Installation at indoor site The products splash-proof specification is IPX4.

0.6~1Nm 11 <> D-M9NM9PM9BM9NM9PVM9BV D-M9NWM9PWM9BWM9NWM9PWVM9BWV D-M9NAM9PAM9BAM9NAM9PAVM9BAV D-A90A93A96A90VA93VA96V 5. <> 6080 D-M9A(V) M3M3 0.60.7Nm (M2.5) (M2.5)0.050.1Nm 56mm 1)(M2.5) 2)M3 BMA3 A 12 4 1) (BMA2-A)(BJ5-1/) () 2) (BMA2-AS/)(BJ4-1/) D-M9A(V) () BBA3:D-B5,B6,G5,K5 BBA4:D-C7,C80,H7 3)BBA3 Best Pneumatics No.

x 0.5 M5 x 0.8 Port size Top ported M3 x 0.5 M5 x 0.8 Deflection accuracy 0.03 mm or less *1) Single vane 90can be adjusted to 9010(both ends of rotation 5each) Single vane 180can be adjusted to 18010(both ends of rotation 5each) *2) Operate within the speed adjustable range.

Model Bolt Max.tightening Torgue (Nm) JMHZ2-16D M3 x 0.5 0.59 Attachment 16 - How to Mount Air Gripper (1)Mounting to the robot arm (2)Mounting of the cover Take care not to get the switch cable caught when mounting the cover.

Model Bolt Max.tightening Torgue (Nm) JMHZ2-16D M3 x 0.5 0.59 Attachment 15 How to Mount Air Gripper Adjust the robot arm position before mounting so that the mounting is easy. (1) Mounting to the robot arm (2) Mounting of the cover Take care not to get the switch cable Caught when mounting the cover.

Model Bolt Max.tightening Torgue (Nm) JMHZ2-16D M3 x 0.5 0.59 Attachment 14 How to Mount Air Gripper Connector storage Set the three connectors at the end of the robot hand according to the characters printed on the flange. The connection part of the connectors are set in the direction of the arrows.

JMHZ2-16D-X7400B-HC10-(*) P13P14P15 4 M6 31.5 2XM4x0.7 8 4 M6 108.8L 4 4 M4 4 M3 27 17 10 - JMHZ2-16D-X7400B-HC10DT-(*) 4 M6 32.5 8 4 M6 109.8L 4 4 M4 4 M3 27 17 11 - 3-6. M8 8 M8-Molex P .19 NPN PNP No. 1 +24V DC24V 2 GND DC0V 3 ON/OFF() 4 ON/OFF() 5 () 6 () 7 8 Molex (51227-0800) M8 8 12 - 3-7.

Refer to the table below Bolt pull Model Belt Pull tension Model Bolt size Tightening [N] Part number torque [Nm] EQFS25 LE-D-15-1 19.6 EQFS25 M3 0.6310% EQFS32 LE-D-19-1 49.0 EQFS32 M4 1.510% EQFS40 EQFS40 LE-D-19-2 70.0 19 - "Pulley plate" is installed.

(Only "With motor cover") (Nm) M2.5 0.3610% M3 0.6310% M4 1.510% M5 310% The fingernail of "Grommet" is inserted in the hole of "Pulley box". Grommet 43 - 7. Troubleshooting Alarms below are abstract of representative examples. For other alarms, see operation manual of controller. No.

MOT3 (6 ) 17 ENC4 (16 ) 4 18 MOT4 (6 ) ) (+)3 (+) 3 (+)4 (+)4 (+) 19 CI 3 4 ) 3 4 (+)(-) 20 M PWR 3 4 )5. 26 No.SFOD-OMT0009CN-B 4.3 (1) 5.5 (2) DIN 27 No.SFOD-OMT0009CN-B 4.4 (1) DIN (a) (4 M5 ) (M5)X4 (b) DIN DIN DIN (M5X8) DIN 2 4 3.0[Nm] M5X8 DIN 1 2 2 3.0[Nm] DIN M5X14 A DIN B DIN DIN (M5X14) 0.40.6 [Nm] 0.40.6[Nm] 28 No.SFOD-OMT0009CN-B A B M5X14 (2) M3

-38No.JXC-OMT0001CN-C (3) : CI C24V (+) (+) EMG1/EMG3 (+) 1 3 (+) (24V ) EMG2/EMG4 (+) 2 4 (+) (24V ) C24V EMG1/EMG3 EMG2/EMG4 LKRLS1/LKRLS3 LKRLS2/LKRLS4 LKRLS1/LKRLS3 + 1 3 (+) LKRLS2/LKRLS4 + 2 4 (+) PHOENIX CONTACT ( FK-MC0,5/5-ST-2,5) 2) AWG20(0.5mm oC 60 2.0 8mm -39No.JXC-OMT0001CN-C 6.2 (1)(3) C PWRCI M PWR (1) +24V 24-0V 24V 0V (24-0V) (24V) (0V) (+24V) M24V 0V 24V 0V M3

Loosen the hexagon socket head cap screws (M3 x 30:2 locations) which are fixing the SI unit. 2. Separate the SI unit to valve manifold. 3. Add and increase the attached tie-rod (2 pcs. per block) to the increased block respectively and pass through a block by the tie-rod. 4.

Caution (1)For M3, M5, 10-32UNF Tightening method (10)Do not apply excessive force or shock to For M3 First, tighten it by hand, then give it an additional 1/6 turn to 1/4 turn with a hexagon wrench. Refer to Table below for reference. the body or fittings with an impact tool.

The terminal screw is an M3 cross head screw. Note: Connect the ground terminal to ground. Resistance to ground should be 100 ohms or less. A. Single power supply used B.

Insulation resistance 1000 M Withstand voltage 1000 V Operating temperature range -30 to +55 oC VCTF 2 core cable (0.75 mm2 x 2) VCTF 4 core cable (0.75 mm2 x 4) Use the M3 crimped terminal for the connection.