, 800 1000 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 1000 Unit: MPa Bore size (mm) 32 40 50 63 80 100 Min. operating pressure 0.02 0.01 Note 1) Intermediate strokes not listed above are also available.
Dimensions (mm) A B C D E F G K L M N P Model IDFA100F IDFA125F Port size R2 670 460 335 107 700 1120 1276 267 1375 20 712 752 R2 1/2 700 655 350 78 935 IDFA150F E D B 10 note) A G F C N M L K Note) In addition to the overall length of the body, the filter mounting part (bracket) projects 10 mm.
, 800 (Both sides) 1300 25 12-CY3B25 Non-lube 32 12-CY3B32 100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 12-CY3B40 40 Note 1) Stroke exceeding the standard stroke but below the maximum possible stroke is available for special order upon request.
Ventilation direction Heavy duty auto drain Terminal block for signal 1.6 (40) 4 x 0.79 (20) 28.0 (712) 0.078 (2) 0.79 (20) 27.6 (700) 0.039 (1) 3.7 (94) 4.2 (107) 3.0 (75) 29.6 (752) Drain tube (O.D. 0.39 (10), Length approx. 6.6 FT (2 m)) (Can also be connected on the other side.)
Made to Order (Refer to page 700 for details.) 699 AS-FG Series How to Order AS 200 1 F G 06 Lock nut option Nil J Hexagon lock nut Round lock nut Body size 100 200 205 300 400 M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard Made to Order (Refer to the below for details.) Applicable tubing O.D.
Series Specifications Bore size (mm) 20 25 32 40 50 63 80 100 Action Double acting, Single rod Lubricant Not required (Non-lube) Fluid Air CJ1 Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa CJP Minimum operating pressure 0.05 MPa Ambient and fluid temperature Without auto switch: 10C to 70C (No freezing) With auto switch : 10C to 60C CJ2 Symbol Piston speed 50 to 1000 mm/s 50 to 700
Up to 700 B C A AL B1 D E F G H H1 J K KA M MM N P S ZZ 30 35 35 40 40 27 32 32 37 37 60 70 85 102 116 22 27 27 32 41 44 52 64 78 92 16 20 20 25 30 32 40 40 52 52 10 10 10 14 14 15 17 17 21 21 51 58 58 71 72 8 11 11 13 16 M8 x 1.25 M8 x 1.25 M10 x 1.25 M12 x 1.75 M12 x 1.75 6 7 7 10 10 14 18 18 22 26 11 11 14 17 17 M14 x 1.5 M18 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 27 30 31 37 40 1/4 3/8
Basic style: CA2YB 4-J 2-P (Rc, NPT, G) MM Width across flats KA G G RE A B REC CX D E CY H1 MQQ M AL B1 K A N F N B C M S + Stroke H RHC ZZ + Stroke MK(2) RS Q G (mm) Bore size (mm) 40 50 63 80 100 Stroke range Up to 500 Up to 600 Up to 600 Up to 700 Up to 700 RS H A B C A AL B1 D E F G H H1 J K KA M MM N P S ZZ 30 35 35 40 40 27 32 32 37 37 60 70 85 102 116 22 27 27 32 41 44 52 64 78 92
T OS W I T C H C A P A B L E A U T O S W I T C H 2 Pieces S 1 Piece See Accessories Without Auto Switch D With Auto Switch S T R O K E A D J U S T M E N T S T R O K E ( I N C H) M O U N T I N G With Adjustment Bolts (Std) B With Shock Absorber BC With Cap Type Shock Absorber BCS With One Cap Type Shock Absorber B Housing fixed P End plate fixed 100 1 200 2 300 3 400 4 500 5 600 6 700
Up to 700 RS H A B C A AL B1 D E F G H H1 J K KA M MM N P S ZZ 30 35 35 40 40 27 32 32 37 37 60 70 85 102 116 22 27 27 32 41 44 52 64 78 92 16 20 20 25 30 32 40 40 52 52 10 10 10 14 14 15 17 17 21 21 51 58 58 71 72 8 11 11 13 16 M8 x 1.25 M8 x 1.25 M10 x 1.25 M12 x 1.75 M12 x 1.75 6 7 7 10 10 14 18 18 22 26 11 11 14 17 17 M14 x 1.5 M18 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 27 30 31 37 40 1
with pre-wire connector, refer to page 8-30-52. 8-29-1 2 Series CXS Specifications 15 6 10 20 25 32 Bore size (mm) Fluid Proof pressure Maximum operating pressure Minimum operating pressure Ambient and fluid temperature Piston speed Cushion Stroke adjustable range Port size Bearing type Air (Non-lube) 1.05 MPa 0.7 MPa 0.1 MPa 0.05 MPa 0.15 MPa 10 to 60C (No freezing) 30 to 600 mm/s 30 to 700
) Vibration resistance 98 m/s2 in each X, Y, Z direction, 3 times (De-energized) Impact resistance Standard CE marking, UL (CSA) Tie-rod 2 pcs.
The operating time for D-J51 is 2 ms or less and for D-P3DW/P4DWL is 40 ms or less. 4) 980 m/s2 for the trimmer type sensor section, 98 m/s2 for the amplifier section.
Mount switches in locations where there is no vibration greater than 98m/s2, or impact greater than 490m/s2. 3. Do not use in an area where surges are generated.
to reach to the Speed (Unit: mm/s2) The setting to define the pushing operation or the positioning operation.
(Unit: 1 mm/s2) XX JOG 1 to "Max ACC/DEC" of the basic parameter acceleration Defines the JOG operation deceleration. (Unit: 1 mm/s2) XX JOG 1 to "Max ACC/DEC" of the basic parameter deceleration JOG thrust *1) Defines the torque limit during JOG operation. (Unit: 1%) XX Fixed distance 0.01 to Full stroke *1) Defines the Inching distance.
Do not drop, bump, or apply excessive impact (PSE530, 540: 980 m/s2, PSE560: 500 m/s2, PSE550: 300 m/s2) while handling. Although the body of the sensor may not be damaged, the inside of the sensor could be damaged and lead to malfunction. 2. The tensile strength of the cord is PSE530: 23 N, PSE540, 550, 560: 50 N or less. Applying a greater pulling force to it can cause malfunction.
10 to 500Hz at whichever is smaller: 1.5mm amplitude or 98m/s2 acceleration in X, Y, Z directions for 2 hrs. each Vibration resistance 490m/s2 in X, Y, Z directions 3 times each Impact resistance Noise resistance 1000Vp-p, Pulse width 1s, Rise time 1ns Weight Note 3) 410g 470g 650g 1,100g Port size (Rc, NPT, G) 3/8 3/8, 1/2 1/2, 3/4 3/4, 1 Note 1) The system accuracy when combined with PF2W3
Acceleration/Deceleration: 5,000 [mm/s2] It is possible to obtain an approximate cycle time by using method 1, but if a more detailed cycle time is required, use method 2. W 200 Cycle time: 0.5 seconds Method 1: Check the cycle time graph.
8 9 A B C D E F 1 4.1 + *S2 S1 DC24V MADE IN JAPAN 2 3 4 (48.5) (50) 133 10.5 10.5 5.1 4.5 5 5 Models Output unit can be used for mixed connection with PCW series.