SMC Corporation of America
Elite Part Number Search
Search Results "JSXFAF-14N-B-S"

the total amount of vertical deflection NC D X 2 N N O O F A U T O S W I T C H E S A U T OS W I T C H C A P A B L E A U T O S W I T C H 2 Pieces S 1 Piece See Accessories Without Auto Switch D With Auto Switch S T R O K E A D J U S T M E N T S T R O K E ( I N C H) M O U N T I N G With Adjustment Bolts (Std) B With Shock Absorber BC With Cap Type Shock Absorber BCS With One Cap Type Shock

MXH MXH Vertical Horizontal MXS L1: Load eccentricity MXQ m Mounting orientation m MXQ L H MXF L H MXW Maximum speed (mm/s) Up to 100 Up to 300 x Up to 500 Up to 100 100 b 50 v 200 n 50 m Up to 300 100 , 200 .

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Body material Stainless steel: S NBR : A FKM : B EPR : C Fluid BC6: Standard NBR : A FKM : B EPR : C Aluminum: L NBR : A FKM : B EPR : C Seal material Applicable fluids VX3 Air (Standard, Dry) Refer to Table (1) to check that the desired fluid is applicable

Circuit example CLJ2 Retraction locking: B Extension locking: F CLM2 W A B CLG1 1 A Emergency stop Drop prevention CL1 B W MLGC W A CNG B 2 A MNB W B CNA W CNS A A 3 CLS B B CLQ W RLQ W A MLU A 4 B MLGP B W ML1C Mounting Caution 1. Be sure to connect the load to the rod end with the cylinder in an unlocked condition.

(2) Conversion formula from the measurement value to the process data: (PD) = (Pr b) / a Pr: Measurement value and directive value PD: Measurement value (process data) a: Inclination b: Intercept [Inclination and intercept to the unit specification] Applicable products Unit Range Inclination a Intercept b 4 L/min 0.004 0 16 L/min 0.016 0 L/min 40 L/min 0.04 0 100 L/min 0.1 0 250 L/min 0.25

/s 14h 10%100%1016 0Ah 0Ah 14h RWwn+7 15bi 8bit 7bit 0bit 16 16 (WORD) ) (RWwn+1)100mm/s 16 100mm/s 0064h 00 64 h 32 32 ) (RWwn+2,3)700.00mm 0.01mm 700.00mm 7016 00011170h 00 01 11 70 h 64h 00h RWwn+1 15bit 8bit 7bit 0bit 01h 00h RWwn+2 15bi 8bit 7bit 0bit 70h 11h RWwn+3 15bi 8bit 7bit 0bit 39 - 12.2 IF ( ) IF ID ID=1 bit 7 6 5 4 3 2 1 0 I_Address RWrn+8 bit F E D C B A 9 8 I_Address

Cv C[dm2/(sbar)] b Cv Flow characteristics 1 2 (P A) 2 3 (A R) Body ported Max. operating frequency (c/s) (AC/DC) (1) 15 21/21 or less 0.125 15 21/21 or less 0.250 Response time (ms) (AC/DC) (2) Weight (kg) (3) Note 1) Minimum operating frequency: As per JIS B 8373 (Once in 30 days) Note 2) Based on JIS B 8375-1981 (Supply pressure; 0.5 MPa; without surge voltage suppressor) Note 3) Value

ZX B B' A B ZR A B P1 A A' ZM !0 o r t ZH ZU Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com e ZL ZY ZQ ZF ZP !1 ZCU Section A-A' (Ejector) AMJ !

Hold either body A (1) or body B (2), and separate the body A and B by pushing the vane shaft (3) out. 4. Take out the vane shaft (3), stoppers (4). (The stopper pin must not be removed from the stopper.) B 1. Mount the vane shaft (3) into the body B (2). 2. Mount the stopper seals (6) into the stopper (4). 3. Mount the stoppers (4) into the body B (2).

s b l t h g i e W ) 7 . 0 ( 4 5 . 1 ) 1 . 1 ( 3 4 . 2 ) 5 . 2 ( 1 5 . 5 ) 5 . 4 ( 2 9 . 9 t e k c a r B P 4 2 B P 5 2 B e g u a G 5 2 O R A N . d t S ) g i s p 0 6 1 ~ 0 ( n o i t p O K50A-MP1.0-N02M K50A-MP2.0-N02M 5 3 O R A N . d t S ) g i s p 0 3 ~ 0 ( How To Order N R NAR 4 25 02 B Body size Option 4 1/2 6 1 8 11/2 9 2 Nil None R IN-OUT Reversal (RightLeft) Pressure regulating range

L S L L-bracket (Bracket on a single side) K J H E F G 2 x D t C B A Long clamping screw set for 1 station required for assembly needs to be ordered separately.

Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers. Fig. 3-15 Connection of RS-232C HRS Series 3.3Installation 3-27 HRX-OM-S004 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly.

Note 2) M-type plug connector is not available with the model with pressure sensor. 13A Table 3 Supply valve/release valve accessories Manual override Note 3) Supply valve/release valve model Accessories ZB1-VQ110UZB1-VQ110U-B ZB1-VQ110LZB1-VQ120UZB1-VQ120U-B ZB1-VQ110ZB1-VQ110-B Nil B Mounting screw (M1.7 x 0.59 inch (15 mm)) 2 pcs.

Valve model Type of actuation Port size 1 4/2 (P A/B) Flow characteristics Note 2) Note 3) Effective area mm2 4/2 5/3 (A/B EA/EB) Weight (g) Pilot port size Cv C [dm3/ (s bar)] b Cv C [dm3/ (s bar)] b Grommet Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center Single Double Closed center Exhaust center Pressure center 48

Nil L R S a b h g d c f e Operating direction Left Right Note) Plugs are installed in ports other than those indicated for the model.

Data L R S Piping Port Locaition Nil Operating direction Left Right L R S a b h g d c f e Note) Plugs are installed in ports other than those indicated for the model. Applicable Auto Switch/Refer to page 8-30-1 for further information on auto switches.

0.5 s 1 s 1.5 s 2 s 2.5 s 50 50 100 100 150 150 200 200 1500 0 150 300 450 600 750 900 1050 1200 1350 1500 0 150 300 450 600 750 900 1050 1200 1350 Distance [mm] Distance [mm] 3) Supply pressure: 0.2 MPa Flow rate consumption: 188 L/min (ANR) 4) Supply pressure: 0.3 MPa Flow rate consumption: 253 L/min (ANR) 200 200 150 150 2.5 s 2 s 100 100 50 50 0.5 s 1 s 1.5 s 2 s 0.5 s 1 s 1.5 s 50 50

D-A9V D-F9V D-F9WV A 22 (20) 5 (7) W B The dimension in ( ) is for D-F9V and D-F9WV. (mm) D-A9, D-A9V D-F9, D-F9W D-F9V, D-F9WV Bore size (mm) A A W B W B W A B 20 25 32 22 22 13 (10.5) 19 18 9 19 11 15 24.5 24.5 9 (6.5) 15 20 5 15 7 11 26.5 26.5 11.5 (9) 17.5 22.5 7.5 17.5 9.5 13.5 Values in ( ) are dimensions for D-A93 type.

Stainless Steel Cylinder Series CJ5-S/Series CG5-S 10, 16 20, 25, 32, 40, 50, 63, 80, 100 For use in environments with water spray such as food processing machines Stainless Steel Cylinder Series CJ5-S/Series CG5-S Series CJ5-S/Series CG5-S Series CJ5-S/Series CG5-S 10, 16 20, 25, 32, 40, 50, 63, 80, 100 Uses grease for food processing machines that meets FDA (U.S.

OUT IN BUS COM A COM B COM C COM D F R P B U S O I R DIA BF SOL RUN GATEWAY UNIT EX500 SERIES 18 19 Switch setting Open the station number switch protective cover and set the switches with a sharp-pointed watchmakers screwdriver etc. NOTE 1. Be sure to turn off the power before setting the switches. 2. Be sure to set these switches before use.