SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-L-P-01-A2"

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: None, Option 3: Y (w/o Operation Manual, w/o Calibration Certificate)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: P (PNP Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: 01 (R 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: None, Option 3: Y (w/o Operation Manual, w/o Calibration Certificate)

Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L3 [Out: IO-Link, Switch Output (N/P); Func: Analog Voltage Output <-> External Input; Monitor Unit Model: PFG300 Series], Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: Units Selection Function, Calibration Certificate: A (Yes)

Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: w/Lead Wire and M12 Connector, 3m, Unit Specification: Units Selection Function, Calibration Certificate: A (Yes)

Series: 25A-ISE20, Rated Pressure Range: B (-0.1 TO 1 Mpa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Series: 25A-ISE20, Rated Pressure Range: B (-0.1 TO 1 Mpa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: M5 (Female Thread), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)

Series: 25A-ISE20, Rated Pressure Range: -0.1 TO 1 Mpa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -

Series: 25A-ISE20, Rated Pressure Range: -0.1 TO 1 Mpa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: Female Thread, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -

Controller Mounting: D (DIN Rail Mouting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB), Digital Pressure Switch: P (ISE20A-Y-01-J-X603)

The ISE2 series is a compact, pressure switch (for positive pressure) and can be integrated with ZX or ZR vacuum systems. The ISE2 series pressure switch has a quick response time of 10mS and the plug connector option makes wiring easy and simple., 3 SCREEN HI PRECISION DIG PRESS SWITCH, PRESSURE SWITCH, ISE1-6, N59, 32 lb

Rated Pressure Range: -0.1 to 1 MPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: Y (w/o Operation

This is a legacy product, and replaced byISE30A-01-P-LD

IO-Link Device Process Data (Example using the ISE20B-L) 24 8.6.3. IO-Link Device Identification (Example using the ISE20B-L) 24 8.6.4. IO-Link Device Observation (Example using the ISE20B-L) 25 8.6.5. IO-Link Device Parameter (Example using the ISE20B-L) 26 8.6.6. IO-Link Device Diagnosis (Example using the ISE20B-L) 27 8.6.7. IO-Link Device Scope (Example using the ISE20B-L) 27 8.6.8.

Stations: 01 (1 Station), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 40 (5 to 40 L/min), Return Unit Components: W (w/Flow Adj.

Accuracy: Basic, Motor Mounting Position: L (Left Side Parallel), Motor Type: S4 [AC Servo Motor, (Incremental Encoder), 400W], Lead: L (2.86mm), Stroke: 200mm, Dust/Drip Proof: P (IP65, Dust/Drip Proof Specification w/vent hole tap), Motor Option: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped/Body Bottom Tapped (Standard), Cable Type: S (Standard Cable), Cable Length

Sensor Range: 4 [For Positive Pressure (0~500kPa)], Port Size: 01 [R1/8 (M5 Female Thread)], Output Specifications: Voltage Output (1~5V) Type, Lead Wire: L [w/Lead Wire and M12 Connector, (3 m), Right Angle]

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: 01 (R1/8)