Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C6H (ΓΈ6 One-touch Fitting, Straight Type)
(same side) D-Y59A (B), Y69A (B) Y7P (V) 20 1 pc., 2 pcs. (different sides) 70 2 pcs. (same side) D-Y7NW (V), Y7PW (V) Solid state switch Y7BW (V) 1 pc., 2 pcs. (different sides) 25 2 pcs. (same side) 70 D-Y7BAL 1pc., 2 pcs.
(UL standard V-0) R 3 8 R KE 1 2 R Note 1) : Brass parts are electroless nickel plated, provided as standard.
x T3 5 pcs. t Packing V#6500 AL-61S AL-60S y Gasket AL-62S AL63S 3 pcs. AL-31S JIS B 2401G35 5 pcs. u O-ring NBR JIS B 2401G35 1 pc. JIS B 2401G35 1 pc. JIS B 2401G35 3 pcs.
Circuit (class 2) of maximum 30 Vrms (42.4 V peak) or less, with UL 1310 class 2 power supply unit or UL 1585 class 2 transformer. The product is a UL approved product only if it has a mark on the body.
The end angular speed is obtained by: t Table 9 Allowable kinetic energy (J) Size Allowable kinetic energy : Rotation angle [ rad ] : Rotation time [ s ] 1 0.001 Kinetic energy E is obtained by: 2 0.0015 3 0.002 7 0.006 E Therefore, the rotary table rotation time is: E: Allowable kinetic energy [ J ] : Rotation range [ rad ] I: Moment of inertia [ kgm2 ] During uniform acceleration, the
t V#6500 O.D.268 X I .D.225 X T3 1 pc. O.D.218 X I.D.175 X T3 1 pc. Gasket AL-62S AL63S 3 pcs. AL-31S y JIS B2401G35 5 pcs. O ring JIS B2401G35 1 pc. JIS B2401G35 3 pcs. JIS B2401G35 3 pcs.
3.6 l\rJ mm3 cm3 (cc) m3 L L rn3 in3 Energy ft3 N. m f t 3 J gar(u.s.)
UJ I 2-Forled \bBion DIMENSIONS A B c o E F G H J K M P R s T 1.57 (40) 2.52 (64) 2.20 (56) 1.77 (45) 4.80 (1221 1.97 {50} 0.98 (25) 1 . 1 0 (28) 0.51 (13) 4.45 (113) ?
HOW TO ORDER N V F 1 1 0 H s D Z O 0 1 T F T T Opo.afing Pressure -J I 0 100 psi (CrP.055) | ' H 0 r 150 psi (C\p.05) | Solen
3.6 l\rJ mm3 cm3 (cc) m3 L L rn3 in3 Energy ft3 N. m f t 3 J gar(u.s.)
UJ I 2-Forled \bBion DIMENSIONS A B c o E F G H J K M P R s T 1.57 (40) 2.52 (64) 2.20 (56) 1.77 (45) 4.80 (1221 1.97 {50} 0.98 (25) 1 . 1 0 (28) 0.51 (13) 4.45 (113) ?
HOW TO ORDER N V F 1 1 0 H s D Z O 0 1 T F T T Opo.afing Pressure -J I 0 100 psi (CrP.055) | ' H 0 r 150 psi (C\p.05) | Solen
Output mode Hysteresis, Window comparator, Error output, Output OFF Switch operation Normal output, Reversed output Maximum load current 80 mA Switch output (SIO mode) Maximum applied voltage 30 V (NPN output) Internal voltage drop (Residual voltage) 1.5 V or less (at load current of 80 mA) Delay time*1 1.5 ms or less, variable from 0 to 60 s/0.01 s increments Hysteresis Hysteresis mode Variable
V Triple seal construction Triple seal construction New PFA New PFA New PFA Series LVN Tubing Series TL/TIL Tubing Series TL/TIL V 1/8" x 1/16" additionally released.
1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)0.6 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 2.4 to 20 mA ?2.5% F.S.?1% F.S. or lessMaximum load impedance: Power supply voltage 12 V: 300 , Power supply voltage 24 V: 600 Minimum load impedance: 50 4-digit, 7-segment, 2-color LCD (Red/Green)?2% F.S. ?1 digit (Ambient temperature of 25 ?
Selection 11 Piston Rod Strength 12 Pneumatic Cylinder Force 13 Air Cylinder Speed 14 Air Consumption Rates 15-19 Frequently Asked Questions Section III 20-24 Circuits 20 Basic Control 21-24 Advanced Control Circuits Section IV 25-28 Charts 25 Pneumatic Pipe Size 25 Pneumatic Pressure Loss 26 Air Flow loss through Pipes 27 Friction of Air In Hose 28 Vacuum Flow Through Orifices Section V
Selection 11 Piston Rod Strength 12 Pneumatic Cylinder Force 13 Air Cylinder Speed 14 Air Consumption Rates 15-19 Frequently Asked Questions Section III 20-24 Circuits 20 Basic Control 21-24 Advanced Control Circuits Section IV 25-28 Charts 25 Pneumatic Pipe Size 25 Pneumatic Pressure Loss 26 Air Flow loss through Pipes 27 Friction of Air In Hose 28 Vacuum Flow Through Orifices Section V
VO301-00T-X302 Conduit terminal 100 V, 200 V, Other voltage (Option) 24 V, Other voltage (Option) 15 to 10% of the rated voltage Class B or equivalent (130C) 70C or less (When rated voltage is applied.) 12 VA (50 Hz), 10.5 AV (60 Hz) 7.5 VA (50 Hz), 6 VA (60 Hz) 4.8 W Non-locking push type LVA Allowable voltage fluctuation Coil insulation type Temperature rise LVH LVD Inrush Holding Apparent
0 0 V R [CR] + 0 1 2 3 4 5 (10 ) 28 - # 0 0 D R [CR] No.