SMC Corporation of America
Elite Part Number Search
Search Results "G46-10-01-SRB-C"

Fault No.10 Fault Probable cause Recommended error handling Recommended action SI unit NS LED is green flashing Refer to the master device manual, and review the settings.

No.EX-OMP0004CN-I SI (CC-Link ) // EX260-SMJ 2 8 9 10 10 11 LED 16 21 26 26 27 28 -1No.EX-OMP0004CN-I (ISO/IEC)(JIS) 1) 2) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO 10218: Manipulating

(Becomes close to the trapezoidal acceleration as the setting value reaches 0) Acceleration and deceleration ratio 10 10 10 10 to 100 EQFS251 to 50 EQFS321 to 70 EQFS401 to 70 Torque when held *2 50 70 70 Sets the torque when stopped after the positioning operation. (Unit: %) H 140 80 80 Sets the position loop P constant.

(C or F). Read the circulating fluid discharge temperature which is displayed on the touch panel.

Example) AL30-03B-2R Symbol Description Body size 20 30 40 50 60 10 Metric thread (M5) Rc NPT G Nil Thread type N F + M5 01 02 03 04 06 10 M5 1/8 1/4 3/8 1/2 3/4 1 Port size + Nil B Note 1) Option (Mounting) Without mounting option With bracket + Polycarbonate bowl 1000 cm3 tank 1000 cm3 tank (with switch) Lowest limit ON 1000 cm3 tank (with switch) Lowest limit OFF Metal bowl Nylon bowl

MU-D02 MU-D03 MU-D04 MU-D05 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.070 0 8 10 10 14 8 10 10 14 Applicable pin no. CD-MU02 CD-MU03 CD-MU04 CD-MU05 DZ 8 10 10 14 CZ 8 10 10 14 DY 9 11 13 16 CX 9 11 13 16 DX 18 22 26 32 CT 9.5 11 14 17 DT 9.5 11 14 17 CR 5.3 6.4 8.4 10.5 DR 5.3 6.4 8.4 10.5 CL 26 42 54 64 DL 26 42 54 64 Part no.

10 x 2), 16 (12 x 2) Standard: JMGPM WA + Stroke/2 Z X 4 x YY depth YL Bottom view WA + Stroke/2 Z 4 x OA through 4 x OB counterbore depth OL 4 x MM depth ML L 2 x P (Plug) (OL) 4 x NN through PW X U H VA PE T R 2 x P (Plug) 2 x P D 2 x P (Plug) GB GA S Q JC J K PD C + Stroke FB FA G A + Stroke [mm] Bore size Standard stroke A C D FA FB G GA GB H J JC K L MM ML NN 12 (10 x 2) 10, 20, 30,

Allowable voltage fluctuation is 10% of the rated voltage.

(Becomes close to the trapezoidal acceleration as the setting value reaches 0) Acceleration and deceleration ratio 10 10 10 to 100 EQY251 to 50 EQY321 to 70 Torque when held *2 50 70 Sets the torque when stopped after the positioning operation. (Unit: %) H 150 100 Sets the position loop P constant.

36 44 M4 10 10 13 13 10 10 12 12 12 12 12 16 7 7 7 9 6.5 5.5 5.5 +0.058 0 +0.070 0 +0.070 0 M4 6.5 10 10 5.5 9 9 5.5 7 10 M5 M5 Y-type double knuckle joint Bracket pin Material: Carbon steel 20: Y-02 25: Y-03 Material: Rolled steel 32: Y-04A 40: Y-04B Material: Cast iron 2-D drill through RR1 C1 Chamfer RR1 C NDH10 NDH10 MM C1 Chamfer A B E1 E1 NX NZ NZ NX U1 A1 A1 U1 L1 L1 Part no.

How to Order VR2110 01 Port size 01 Rc1/8 N01 NPT1/8 F01 G1/8 10 5. Operation Patterns ON timing: ON upon the set delay Output method: Normal close Settable time delay: 0.5 to 60 seconds Operation time chart is shown in Fig. 1. Time delay (Input signal) Time (Output) Fig. 1: Operation timing chart When an Input Signal Pressure is provided, Output turns ON after the preset time.

MU-D02 MU-D03 MU-D04 MU-D05 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.070 0 8 10 10 14 8 10 10 14 Applicable pin no. CD-MU02 CD-MU03 CD-MU04 CD-MU05 DZ 8 10 10 14 CZ 8 10 10 14 DY 9 11 13 16 CX 9 11 13 16 DX 18 22 26 32 CT 9.5 11 14 17 DT 9.5 11 14 17 CR 5.3 6.4 8.4 10.5 DR 5.3 6.4 8.4 10.5 CL 26 42 54 64 DL 26 42 54 64 Part no.

Ground wire (1.5 m)/Accessories IZH-A-01 High-voltage measuring handle/Option IZH-C-01 Soft case/Accessories IZH-B-01 High-voltage measuring handle Ground wire Soft case Note) Be sure to use a high-voltage measuring handle in situations such as during high-voltage measurement when there is a possibility of personnel coming in contact with electricity.

L D d m t d H B C l 0.040 0.076 0.050 0.093 32, 40 C type 10 for shaft NT-04 IY-G04 32, 40 41.6 9.6 36.2 1.55 1.15 M14 x 1.5 8 22 25.4 C type 14 for shaft 10 50, 63 NT-05 IY-G05 50, 63 50.6 13.4 44.2 2.05 1.15 M18 x 1.5 11 27 31.2 14 Retaining rings are included.

If the minimum setting unit is 1 L/min, the flow can be displayed in 1 L/min units, i.e. 10, 11, 12. Minimum setting unit N Normal condition (NOR) Reference condition for volumetric flow: 101.3 kPa, 0 C The flow measurement which is converted at normal atmospheric pressure conditions at 0 C.

If the installation is using accurate control, wait until the product has warmed up (approximately 10 to 15 minutes). 1.0 to 1.2 Yellow ZS-28-C-1 Do not operate in an atmosphere containing flammable or explosive gases. Fire or an explosion can result.

I-MU02 I-MU03 I-MU04 I-MU05 R1 3 4 5 6 NZ 18 22 26 32 NX 9 11 13 16 NO 21 24 27 39 NL 8 10 10 16 R1 8.5 10 11 16 NDH10 NL 8.5 10 11 16 NX 9 11 13 16 NO 19.5 24 26 36 U1 11 14 15 20 U1 13 14 17 23 +0.058 0 +0.058 0 +0.058 0 +0.070 0 8 10 10 14 Knuckle pin and snap ring are included. Clevis pin and knuckle pin Rod end nut 30 d Dd9 d D C l m m t t L H B (mm) (mm) Part no.