TdH9 TB +0.036 0 +0.036 0 +0.043 0 CLG-020-24 CLG-025-24 CLG-032-24 CLG-040-24 20 25 32 40 42 48 53 60 10 10 10 10 5.5 5.5 6.6 6.6 31 37 38.5 42.5 40 47 47 55 20 25 32 40 36 43 50 58 10 10 10 10 5.5 5.5 6.6 6.6 25 30 35 40 (29.3) (33.1) (40.4) (49.2) 8 10 12 14 8 10 12 +0.043 0 14 CG-020-24A CG-025-24A CG-032-24A CG-040-24A Applicable bore size (mm) Applicable bore size (mm) Part no.

MU-D02 MU-D03 MU-D04 MU-D05 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.070 0 8 10 10 14 8 10 10 14 Applicable pin no. CD-MU02 CD-MU03 CD-MU04 CD-MU05 DZ 8 10 10 14 CZ 8 10 10 14 DY 9 11 13 16 CX 9 11 13 16 DX 18 22 26 32 CT 9.5 11 14 17 DT 9.5 11 14 17 CR 5.3 6.4 8.4 10.5 DR 5.3 6.4 8.4 10.5 CL 26 42 54 64 DL 26 42 54 64 Part no.

Output unit How to Order EX510-FC 10 10.16 0.40 Cable length (L) 01 02 05 10 20 60 1 m 2 m 5 m 10 m 20 m 60 m Brown: +24 V Black: Communications + White: Communications Blue: 0 V L Note) (Reference: AWG18) Note) Branch cable length is a maximum of 20 m. Use the cable by cutting it into lengths of 20 m or shorter. w Branch connector (Unit 1 pc.)

Minimum Stroke for Auto Switch Mounting [mm] Auto switch model Number of auto switches Bore size 12 (10 x 2) 16 (12 x 2) 20 (16 x 2) 25 (20 x 2) 32 (25 x 2) 40 (32 x 2) 50 (40 x 2) 63 (45 x 2) 80 (56 x 2) 100 (71 x 2) D-M9V 1 5 2 5 D-M9 1 51 5 2 101 10 D-M9W 1 52 2 102 10 D-M9WV D-M9AV 1 52 2 10 D-M9A 1 52 2 102 1 Confirm that it is possible to secure the min. bending radius of 10 mm of the

Specification for Option M 10 1 Safety instructions . 10 1 10 2 Specifications . 10 2 10 3 Installation of motor type auto drain . 10 3 10 4 Electric circuit . 10 3 Chapter 11 Specification for Option R 11 1 Safety instructions .11 1 11 2 Specifications .11 1 11 3 Power supply connection procedure .11 2 11 4 Cautions for handling the GFCI .11 3 11 5 Electric circuit .11 3 Chapter 12 Specification

x 10-1 ft3 x 10-1 ft3 x 10-1 flow Min. setting/display unit 0.1 ft3 x 10-1 0.1 ft3 x 10-1 1 ft3 x 10-1 1 ft3 x 10-1 Conversion of accumulated pulse 0.1 1 1 1 ft3 x 10-1/pulse ft3 x 10-1/pulse ft3 x 10-1/pulse ft3 x 10-1/pulse : Flow rate in the specification is the value at standard condition.

8 (left side) One-touch fitting 10 (left side) Mixed 02R 03R 02L 03L 02Y 03Y C6R C8R C10R C6L C8L C10L Control equipment Symbol Nil A AP M MP F G C E Air filter with auto drain 10 stations 10 Air filter with manual drain Note) When equipped with control unit, one or two stations are used for mounting.

MU-D02 MU-D03 MU-D04 MU-D05 CJ 7 10 10 14 CI 17 22 27 32 CH 11 13 13 17 CF 4 7 10 12 CE 3.5 3.5 3.5 5.5 CB 23 27 31 37 CA 53 67 85 103 DJ 7 10 10 14 DI 17 22 27 32 DH 11 13 13 17 DF 4 7 10 12 DE 3.5 3.5 3.5 5.5 DB 23 27 31 37 DA 53 67 85 103 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.058 0 +0.070 0 8 10 10 14 8 10 10 14 Applicable pin no.

to 50 oC Detection method Heating type sensor (branch flow type) Rated flow range 10 to 1000 L/min 20 to 2000 L/min Instantaneous flow 10 to 1050 L/min 20 to 2100 L/min Set point range Accumulated flow 0 to 999,999,999,990 L Flow specifications Instantaneous flow 1 L/min 2 L/min Minimum resolution Accumulated flow 10 L Accumulated volume per pulse (Pulse width = 50 msec.)

V) 1 0 V 0.10 V 10 V 1: The analogue output current from the connected equipment should be 20 A or less when selecting 0 to 10 V.

Refer to LECSS2-T Operation Manual,section 3.5 for input/output signal details. -10- 3.3.2 Source Sink I/O interfaces Connection example An example wiring diagram for Sink I/O is shown below Driver Servo amplifier () CN8 (Note 16) Short-circuit connector (Packed with the servo amplifier) 10 m or less driver) (Note 12) CN3 10 m or less 24 V DC (Note 10) 3 DOCOM (Note 15) Main circuit power

Material Description Part number No. 4 5 10 NBR Gasket VVQ5000-80A-1 Type 10 NBR Gasket VVQ5000-80A-2 Option A 1 station Note) Spare parts consist of sets containing 10 pcs. each.

V) 1, 2 0 V 0.1 V 10 V Current output 1 4 mA 4.16 mA 20 mA Models Minimum value of rated flow range Maximum value of rated flow range PFMC7501 5 L/min 500 L/min PFMC7102 10 L/min 1000 L/min PFMC7202 20 L/min 2000 L/min 1: Analogue output accuracy is within 3%F.S. 2: Set the current to the analogue output from the connected equipment to 20 A or less when selecting 0 to 10 V.

Parameter Definition Item Content Default setting 0: -10..10 V 1: -5..5 V 2: -20..20 mA 3: 0..10 V 5 Analog Range Set the analog input range per channel. Selects the analog input range. 0..10 V 4: 0..5 V 5: 1..5 V 6: 0..20 mA 7: 4..20 mA 0: None None 6 Analog Filter Sets analog input filtering time per channel.

V) 1, 2 0 V 0.1 V 10 V Current output 1 4 mA 4.16 mA 20 mA Models Minimum value of rated flow range Maximum value of rated flow range PF2MC7501 5 L/min 500 L/min PF2MC7102 10 L/min 1000 L/min PF2MC7202 20 L/min 2000 L/min 1: Analogue output accuracy is within 3%F.S. 2: Set the current to the analogue output from the connected equipment to 20 A or less when selecting 0 to 10 V.

Port size Symbol 01 02 02 03 03 04 Body class Port size 1/8 1/4 1/4 3/8 3/8 1/2 Pilot port thread type 2 Symbol Nil N Thread type Rc NPT 3 4 Integral fitting type/Variations Model LVH20 LVH30 LVH40 Orifice diameter 4 8 10 Tubing O.D. Metric 3, 4, 6 6, 8, 10 10, 12 Valve type Inch 1/8, 3/16, 1/4 1/4, 3/8 3/8, 1/2 Symbol Type Basic type N.C.

Material Description Part number No. 4 5 10 NBR Gasket VVQ5000-80A-1 Type 10 NBR Gasket VVQ5000-80A-2 Option A 1 station Note) Spare parts consist of sets containing 10 pcs. each.

36 44 M4 10 10 13 13 10 10 12 12 12 12 12 16 7 7 7 9 6.5 5.5 5.5 +0.058 0 +0.070 0 +0.070 0 M4 6.5 10 10 5.5 9 9 5.5 7 10 M5 M5 Y-type double knuckle joint Bracket pin Material: Carbon steel 20: Y-02 25: Y-03 Material: Rolled steel 32: Y-04A 40: Y-04B Material: Cast iron 2-D drill through RR1 C1 Chamfer RR1 C NDH10 NDH10 MM C1 Chamfer A B E1 E1 NX NZ NZ NX U1 A1 A1 U1 L1 L1 Part no.