(same side) 60 D-Y59A(B), Y69A(B) Y7P(V) 1 pc., 2 pcs. (different sides) 20 2 pcs. (same side) 70 D-Y7NW(V), Y7PW(V) Y7BW(V) Solid state switch 1 pc., 2 pcs. (different sides) 25 2 pcs. (same side) 70 D-Y7BAL 1pc., 2 pcs.
Applicable Stroke Table V: Standard Stroke [mm] Model 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1100 1200 LEFS25 V V V V V V V V V V V V V V V V LEFS32 V V V V V V V V V V V V V V V V V V V V LEFS40 V V V V V V V V V V V V V V V V V V V V * Please consult with SMC for non-standard strokes as they are produced as special orders.
US1 LED . 6-6 US1 LED US1 OFF US1 OFF , (17 V ) US1 (17 V 20.4 V) ON US1 ON 21.6 V 6.4.6. US2 LED . 6-7 US2 LED US2 OFF US2 OFF , (17 V ) US2 (17 V 21.6 V) ON US2 ON 22.8 V 49 No.EX-OMU0020CN 6.5.
ON: Red light emitting diode Indicator light Auto Switch Weight Table Unit: g D-F9N(V) D-F9P(V) D-F9B(V) Model Auto Switch Internal Circuits 0.5 7 7 6 lead wire length (m) D-F9N, F9NV 3 37 37 31 5 61 61 51 DC (+) Brown Main circuit switch Main circuit switch OUT Black Auto Switch Dimensions D-F9 Switch mounting screw M2.5 x 4l Slotted set screw DC () Blue 2 Indicator light D-F9P, F9PV 2.7
Description Function 1 SV 24 V +24 V for solenoid valve. 2 SV 0 V 0 V for solenoid valve 3 SW 24 V +24 V for input block 4 SW 0 V 0 V for input block 5 FE Functional earth (Example of connection cable: EX9-AC050-1 etc.) The Power supply connection inside the unit has individual power supplies for solenoid valve actuation (SV power supply) and for Input block (SW power supply).
F9BWV 2-wire Relay, PLC IC circuit No 5 V, 12 V 100 V or less 3-wire (NPN) IC circuit 5 V, 12 V 3-wire (PNP) IC circuit 2-wire 12 V Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 mNil (Example) M9N 3 mL (Example) M9NL 5 mZ (Example) M9NZ Solid state switches marked with are produced upon
IDX-OM-V022-H Original Instructions PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDF60-20-A,C,L,R,T,V IDF60-30-A,C,L,R,T,V IDF70-20-A,C,L,R,T,V IDF70-30-A,C,L,R,T,V IDF80-20-A,C,L,R,T,V IDF80-30-A,C,L,R,T,V IDF90-20-A,C,L,R,T,V IDF90-30-A,C,L,R,T,V This manual is intended to explain the installation and operation of the product.
(NPN) 3-wire (PNP) A96 A96V 5 V M9N M9NV IC circuit 5 V 12 V M9P M9PV 12 V M9B M9BV 2-wire Relay PLC Yes Grommet 24 V 3-wire (NPN) 3-wire (PNP) F9NW F9NWV Diagnostic indication IC circuit 5 V 12 V F9PW F9PWV 2-color indication F9BW F9BWV 2-wire 12 V Lead wire length symbols 0.5 m Nil (Example) F9NW 3 m L F9NWL 5 m Z F9NWZ Solid state switches marked with a symbol are produced upon
(NPN) 3-wire (PNP) A96 A96V 5 V M9N M9NV IC circuit 5 V 12 V M9P M9PV 12 V M9B M9BV 2-wire Relay PLC Yes Grommet 24 V 3-wire (NPN) 3-wire (PNP) F9NW F9NWV Diagnostic indication IC circuit 5 V 12 V F9PW F9PWV 2-color indication F9BW F9BWV 2-wire 12 V Lead wire length symbols 0.5 m Nil (Example) F9NW 3 m L F9NWL 5 m Z F9NWZ Solid state switches marked with a symbol are produced upon
Find the moment of inertia I for the rotation of shaft (B). B 2. I is converted to the rotation of the shaft (A). B 2 r I = m2 2 b a I I = A B Number of teeth=b 5.
2 (A) 4 (B) 2 Note) Not applicable to S kit. 1 A Note) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) Coil voltage B: Locking type (Slotted) N.C N.C 12 VDC 5 6 4 position dual 3 port valve (B) 2 position double (metal) 24 VDC Note) (A) 4 (B) 2 (A) 4 (B) 2 B Note) S kit is only available for 24 VDC.
IDX-OM-W093-B / Series IDF60-20-A,C,L,R,T,V IDF60-30-A,C,L,R,T,V IDF70-20-A,C,L,R,T,V IDF70-30-A,C,L,R,T,V IDF80-20-A,C,L,R,T,V IDF80-30-A,C,L,R,T,V IDF90-20-A,C,L,R,T,V IDF90-30-A,C,L,R,T,V URLhttp://www.smcworld.com/ English instruction manual can be downloaded from our URLhttp://www.smcworld.com/ SMC *1) JIS B8370 *2) ISO4414 *1) ISO4414Pneumatic fluid power Recommendations for the application
Grommet Yes 3-wire (NPN) 3-wire (PNP) 24 V Diagnostic indication (2-color indicator) 5 V, 12 V IC circuit 2-wire 12 V Water resistant (2-color indicator) 3-wire (NPN equivalent) Z76 5 V IC circuit Yes Grommet 12 V 100 V Z73 Relay, PLC 24 V 2-wire None IC circuit 100 V or less Z80 Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee
ON = A (A B)/4 A = Max. pressure OFF = B + (A B)/4 B = Min. pressure -23No.PS-OMH0006-F Setting of Special Function Fine adjustment function of displayed value This makes no dispersion on CH1 to CH4 each output value, and make same displayed value. It is possible to do fine adjustment within 5%R.D. range of the reading data on the displayed value of pressure sensor.
Solid state switches marked with are produced upon receipt of order. 3-wire (NPN) 2-wire Relay, PLC IC circuit 5 V, 12 V 3-wire (PNP) 2-wire 12 V Relay, PLC 24 V Grommet 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 m Nil (Example) A93 3 m L (Example) A93L 5 m Z (Example) F9NWZ Since there are other
(same side) D-Y59A (B), Y69A (B) Y7P (V) 20 1 pc., 2 pcs. (different sides) 70 2 pcs. (same side) D-Y7NW (V), Y7PW (V) Solid state switch Y7BW (V) 1 pc., 2 pcs. (different sides) 25 2 pcs. (same side) 70 D-Y7BAL 1pc., 2 pcs.
JIS B 8370: General rules for pneumatic equipment. JIS B 8361: General rules for hydraulic equipment. JIS B 9960-1: Safety of machinery Electrical equipment of machines. (Part 1: General requirements) JIS B 8433-1993: Manipulating industrial robots Safety. etc. 2) Labor Safety and Sanitation Law, etc. Caution: Operator error could result in injury or equipment damage.
(B contact). Contact output signal 5selects Signal type and N.O. (A contact ) or N.C. (B contact). Contact output signal 6selects Signal type and N.O. (A contact) or N.C. (B contact).
VC 24 VDC 12 VDC 100 VAC 200 VAC 110 VAC SY100-82-3-05 SY100-82-3-06 SY100-82-2-01 SY100-82-2-02 SY100-82-2-03 24 V 12 V 100 V 200 V 110 V A VDW A VQ B DIN Terminal Circuit with Indicator Light VX2 A AC circuit DC circuit Mounting procedure 1) Hook the mounting hook on the side of the manifold base to the DIN rail. 2) Lift the side of the manifold off the DIN rail and slide it in the