Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, VALVE, BODY PORTED (DC), VALVE,
Slim, compact, plug-in manifold bar base, D-sub connector, 25P, conforming to MIL standard, Options: external pilot, built-in silencer, 12 stations available as standard, MANIFOLD, VALVE, S070 SOLENOID VALVE,3-PORT, MJ, S070 BASE MOUNT ( 1.42074 lb
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, VALVE, BODY PORTED, DIN (DC), VALVE
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, VALVE, BODY PORTED, DIN (AC), VALVE
Cart SMC EX260-SPR6 profibus serial interface, EX300 SERIAL INTERFACE UNIT $204.10 + Add to Quote Add To Cart Add to Cart SMC KQ2P-04
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50C, VALVE, BODY PORTED, IP65 (AC), VALVE
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, VALVE, BODY PORTED, DIN (DC), VALVE
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, VALVE, BODY PORTED (DC), VALVE,
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient & fluid temperature: -10 to 50°C, VALVE, BODY PORTED (DC), VALVE,
Fieldbus serial transmission system (EX600), SI unit for input/output , Kit types include DeviceNetÖ, PROFIBUS-DP, CC-Link, EtherCAT, and EtherNet/IPÖ , 1-12 stations available as standard, MANIFOLD, VALVE, S070 SOLENOID VALVE,3-PORT, MI, S070 BASE MOUNT ( Weight: tab 9 1.0306 lb
Fieldbus serial transmission system (EX600), SI unit for input/output , Kit types include DeviceNetÖ, PROFIBUS-DP, CC-Link, EtherCAT, and EtherNet/IPÖ , 1-12 stations available as standard, MANIFOLD, VALVE, S070 SOLENOID VALVE,3-PORT, MI, S070 BASE MOUNT (
, 1-12 stations available as standard, MFLD, REQ MFLD SPEC FORM W/ORD, VALVE, S070 SOLENOID VALVE,3-PORT, MZ, S070 BASE MOUNT Related Items
, 1-12 stations available as standard, MANIFOLD, VALVE, S070 SOLENOID VALVE,3-PORT, MI, S070 BASE MOUNT 3.08647 lb
Speed controller with residual pressure release valve with one-touch fittings, Body sizes: 1/8, 1/4, 3/8, 1/2, Elbow or universal style, Meter-in or meter-out control, Port sizes: 01, 02, 03, 04, Tube sizes O.D. (mm): 4, 6, 8, 10, 12, SPEED CONTROLLER, FLOW CONTROL, SVD, 61 lb
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED, DIN (DC
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC
Fluid: air, inert gas, Operating pressure range: 0.1 - 0.7MPa, Effective area mm 2 (Cv): metal seal 2.0 (0.11) - 12.6 (0.7); rubber seal 3.1 (0.17) - 16.2 (0.9), Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC, Response time (ms) standard 1W, high pressure 1.5W: metal seal 25 or less; rubber seal 30 or less, Ambient and fluid temperature: -10 to 50 C, VALVE, BODY PORTED (DC