R 075 CKQG32X B 08 CKQG32X Guide pin diameter Applicable hole diameter of workpiece Refer to Table 1 (Symbol 2) below Refer to Table 1 (Symbol 1) below Guide pin shape Clamp arm assembly The clamp arm Round type Diamond type includes a basic internal retaining ring. R D Table 1.
ZFC200-08 No. 0.0001 1 10 100 ZFC200, 201 ZFC100, 101 S14 S10 O-ring Accessory BP-17S BP-16S Bracket Flow rate l/min (ANR) O-rings are already installed in spare elements. A bracket is included with the product. 4 Air Suction Filter Series ZFC In-line Type with One-touch Fittings Dimensions (mm) 1in=25.4mm Applicable tubing O.D.
ZR IN side, OUT side (/min (ANR)) Weight (g) Model ZM ZFC100-04 4 10 11.5 ZFC100-06 6 20 ZH Metric size ZFC200-06 6 30 21.5 ZU ZFC200-08 8 50 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ZFC101-03 5/32" 10 11.5 ZL ZFC101-07 1/4" 20 Inch size ZFC201-07 1/4" 30 ZY
Note) 4 6 8 10 12 23 04 06 08 10 12 3.2 TMH-23J TMH-04J TMH-06J ASV Body size AS1001F AS2001F AS2051F AS3001F AS4001F AK TMH-06 TMH-08 ASS TMH-10 TMH-12 Applicable tubing Inch Size ASR Note) Mounting bracket is not available. This is an application example. Applicable tubing size ASF 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 01 03 05 07 09 11 13 Can be mounted on the panel.
KA00809 20 to 24 Element (P85) (AS568-259,Hs70) KA00721 06 to 08 KA00704 (P35) KA00107 10 to 12 (G90) Phosphoric FKM (P44) Case NB00074 ester KA00690 -70 KA00636 e Seal washer 16 (P50) (G130) Drain plug KA00676 KA00725 20 to 24 DRAIN (P85) (AS568-259,Hs70) Note) The material and nominal size notations are based on JISB2401. 518 B
(Nominal size) Port size Hydraulic fluid Material 04 06 08 10 12 16 20 24 28 32 04 06 08 10 12 16 20 24 28 32 AL-128H AL-129H AL-131H AL-132H AL-134H AL-135H AL-136H AL-137H KA00813 (V120) AL-128H-V AL-129H-V AL-131H-V AL-132H-V AL-134H-V AL-135H-V AL-136H-V AL-137H-V KA00728 (V120) KA00815 (V85) KA00812 (V100) KA00813 (V120) KA00814 (V150) KA01800 (V175) KA00731 (V85) KA00727 (V100) KA00728
With One-touch fitting Port size U01 Uni 1/8 U02 Uni 1/4 U03 Uni 3/8 U04 Uni 1/2 Needle Valve/Flow Rate Characteristics AS2201F-U02, AS2211F-U02 AS2301F-U02, AS2311F-U02 AS2201F-U01, AS2211F-U01 AS2301F-U01, AS2311F-U01 300 600 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 06, 07, 08, 09, 10 500 08, 09, 10, 11 Flow rate L/min (ANR) Flow rate L/min (ANR) 03, 04 06, 07 200 400 01, 23 300
Bore size (mm) Part no. l Applicable cotter pin m Dd9 L d H B C 3 x 18 l 4 x 25 l 4 x 35 l 4 x 40 l 32 40 50, 63 80 100 125 32, 40 50, 63 80, 100 125 0.040 0.076 0.050 0.093 0.065 0.117 0.065 0.117 NT-03 NT-04 NT-05 NT-08 NT-10 NT-12M CD-M03Note 1) 10 14 22 25 44 36 4 4.5 5 5 3 4 4 4 M10 x 1.25 M14 x 1.5 M18 x 1.5 M22 x 1.5 M26 x 1.5 M27 x 2 6 8 11 13 16 16 17 22 27 32 41 41 19.6 25.4 31.2
ZFC200-08 No. 0.0001 1 10 100 ZFC200, 201 ZFC100, 101 S14 S10 O-ring Accessory BP-17S BP-16S Bracket Flow rate l/min (ANR) O-rings are already installed in spare elements. A bracket is included with the product. 4 Air Suction Filter Series ZFC In-line Type with One-touch Fittings Dimensions (mm) 1in=25.4mm Applicable tubing O.D.
BAF-10 BA-04 BA-05 BA-06 BA-08 BA-10 CS1 CS2 Note 1) Auto switch brackets are included in the D-A3lC/A44C/G39C/K39C types.
With One-touch fitting Port size U01 Uni 1/8 U02 Uni 1/4 U03 Uni 3/8 U04 Uni 1/2 Needle Valve/Flow Rate Characteristics AS2201F-U02, AS2211F-U02 AS2301F-U02, AS2311F-U02 AS2201F-U01, AS2211F-U01 AS2301F-U01, AS2311F-U01 600 300 Inlet pressure: 0.5 MPa Inlet pressure: 0.5 MPa 06, 07, 08, 09, 10 500 08, 09, 10, 11 Flow rate L/min (ANR) Flow rate L/min (ANR) 03, 04 06, 07 200 400 01, 23 300
Auto switch models Bore size (mm) 32 40 50 63 80 100 D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-F5/J59 D-F5W/J59W D-F5BA/F59F/F5NT D-A5/A6/A59W D-Z7/Z80 BMB5-032 BA7-040 BA7-080 BA7-080 BS5-160 BT-16 BT-03 BT-04 BT-08 BT-08 BT-16 BS4-160 BMB4-050 BA4-080 BA4-080 BS4-160 Note 1) D-M9 cannot be mounted to 100. Note 2) D-A5/A6/A59W/Z7/Z80 cannot be mounted to 32.
A: Lock unit holding bolt R 075 CKQG32X B 08 CKQG32X CK1 B: Cylinder holding bolt Guide pin diameter * Refer to Table 1 (Symbol 2) below. Applicable hole diameter of workpiece * Refer to Table 1 (Symbol 1) below.
AS: AS, Size: 2 (1/8, 1/4 Basis), Style 1: 2 (Elbow), Control Type: 0 (Meter-out), Thread: M5, 10-32UNF, R, Port Size: 02 (1/4), Tube Size: Ø8, Option: None, Lock Nut: J (Round)
Lightweight, point-of-use ZH and ZU series vacuum generators combine design simplicity with high performance. Simply plug an air supply tube in one end, and vacuum is ready at the other end. The slim ZU generators are extra compact. The ZH and ZU immediate response may be quicker than central vacuum systems. Also, these generators are often smaller and lighter than the bulky vacuum lines
AS: AS, Body Size: 2 (1/8, 1/4 Basis), Style: 2 (Elbow), Control Method: 0 (Meter-out), Thread: Metric Thread (M5)/R(PT), Port Size: 02 (1/4), Applicable Tube OD: Ø8, Option: None, Lock Nut: J (Round)
AS: AS, Body Size: 2 (1/8, 1/4 Basis), Style: 3 (Universal), Control Method: 0 (Meter-out), Thread: Metric Thread (M5)/R(PT), Port Size: 02 (1/4), Applicable Tube OD: Ø8, Option: None, Lock Nut: J (Round)
Size: 4 (1/4 Basis), Style: 1 (Union Tee), Thread: M3, M5, U10/32, R, Port Size: 02 (R1/4), Tube Size: Ø8, Sealant: w/o Sealant (M3,M5,U10/32), Option: None, Made to Order: None, Lock Nut: J (Round)