Mounting screw (M4) Terminal block cover M3 Screw Gasket 6mm Electrical entry 2-G3/4 Step 3. How to attach the terminal block cover Securely tighten the screws with the torque shown in the table below, after confirming that the gasket is installed correctly.
Initial value) Note 3) Value for high pressure type (1.5W) specification Note 4) Value for the low power consumption (0.5W) specification 56 Series VQ1000 VQ1000/Flat Cable Kit Stations VV5Q13J 0(D) U S Applicable connector: Flat cable connector (20P) (conforms to MIL-C-83503) L2 23.5 P = 11 13.2 L1 6.2 41 35 Indicator light 1.5 1.5 (11) 19.5 (Mounting hole dimension) Manual override 2-M4
(mm) Electrical entry P Port size B C D E F H K L M N A Model Grommet: G Conduit: C Conduit terminal: T Q R Q R Q R S U 13.5 28 64 31 6.5 12.5 28 14 12.8 M4 4.5 22 59 44 50 99 50 66 83 1/8 VCS21 18 36 67.5 31 8.5 12.5 28 18 12.8 M4 6 22 62 44 53 99 53 66 86 1/4 22 40 81.5 36.5 11 15 32 20 19 M5 8 24 76 46 66.5 101 66.5 68 99 1/4, 3/8 VCS31 30 50 86 36.5 13.5 15 32 25 23 M5 8 24 80 46 71 101
Metric size TMH-06 TMH-08 TMH-10 Inch size TMH-05 TMH-07 TMH-09 TMH-11 M3 x 20 1 M4 x 25 M4 x 35 Shuttle Valve/AND Valve and Holder Compatibility Single unit secured using holder Metric sizes Applicable tubing outside diameter Model Shuttle valve VR1210F VR1220F AND valve VR1211F TMH05 TMH06 TMH06 TMH08 TMH10 3.2 4 6 8 10 Inch sizes Applicable tubing outside diameter Model Shuttle valve
12.8 14 28 12.5 6.5 31 64 28 4.5 13.5 83 66 50 99 50 44 59 22 1/8 VCB21 M4 12.8 18 28 12.5 8.5 31 67.5 36 6 18 86 66 53 99 53 44 62 22 1/4 M5 19 20 32 15 11 36.5 81.5 40 8 22 99 68 66.5 101 66.5 46 76 24 1/4, 3/8 VCB31 M5 23 25 32 15 13.5 36.5 86 50 8 30 104 68 71 101 71 46 80 24 1/2 M5 23 22.5 36 17 11 41 90 45 8 22 107 70 74.5 103 74.5 48 84 26 1/4, 3/8 VCB41 M5 23 25 36 17 13.5 41 94
4.5 1/8 VCL21 86 22 23 46 44 44 58 41.5 46.5 99 44 66 18 36 67 31 8.5 12.5 28 18 12.8 M4 6 1/4 99 24 25 56.5 46 54.5 60 52 48.5 101 54.5 68 22 40 81.5 36.5 11 15 32 20 19 M5 8 1/4, 3/8 VCL31 104 24 25 59 46 57 60 54.5 48.5 101 57 68 30 50 84 36.5 13.5 15 32 25 23 M5 8 1/2 107 26 26.5 64.5 48 62.5 62 60 50.5 103 62.5 70 22 45 89 41 11 17 36 22.5 23 M5 8 1/4, 3/8 VCL41 111.5 26 26.5 66.5 48
switch Exhaust with silencer With digital vacuum pressure switch ZL112-E P V RESET SET Approx. 500 (L: Approx. 2900) Section A Pressure supply port One-touch fitting 6 Vacuum port One-touch fitting 12 2-5.4 Mounting hole Label MULTISTAGE EJECTOR 59.5 59 56 8.5 30 Section A with digital vacuum pressure switch 4.5 166 175 36 ZL112-E (ZSE4) ZL112-EB (ZSE4B) ZL112-EE (ZSE4E) 28 (2) (1.6) 4-M4
/N.O. 2 M4 1.4Nm M4 N.C. N.O. N.C. 3-CL N.O. 3-OP N.C. N.C. N.C. N.C. N.O. N.O. N.O. N.O. N.O.
The signal to DeviceNet is transmitted by GW unit, and the signal to input/output device which is installed discretely is collected by GW unit. 6 FG terminal Used for grounding 7 Mounting hole Used when a unit is mounted with two M4 screws. 8 DIN rail mounting slot Used when a unit is mounted to DIN rail. 9 Display/ switch setting part Sets up the switch on such as LED display and address
The signal to PROFIBUS DP is transmitted by GW unit, and the signal to input/output device which is installed discretely is collected by GW unit. 5 6 FG terminal Used for grounding. 7 Mounting hole Used when an unit is mounted with two M4 screws.
The signal to CC-Link is transmitted by GW unit, and the signal to input/output device which is installed discretely is collected by GW unit. 6 FG terminal Used for grounding 7 Mounting hole Used when a unit is mounted with two M4 screws. 8 DIN rail mounting slot Used when a unit is mounted to DIN rail. 9 Display/ switch setting part Sets up the switch on such as LED display and address,
M4 x 35 AS ASP Correspondence of In-line Speed Controller and Holder ASN Metric Size AQ Applicable tubing Applicable tubing size Adaptable for the manifold application.
Note 2) Set the tightening torque of a hexagon socket head set screw (M4 0.7) to be 1 to 1.2 Nm. * To protect auto switches, ensure that main body of an auto switch should be embedded into auto switch mounting groove with a depth of 15 mm or more. Auto Switch Mounting Bracket Part No.
M5 x 20 Hexagon socket head cap screw Tightening torque: 3.5 0.5 Nm J D side G1/4 port part Tightening torque: 10 1 Nm K G e w q Note) H r q w e Note) e w q Note) F q w E C A U side B D M5 x 20 Hexagon socket head cap screw Tightening torque: 3.5 0.5 Nm Block Assembly C: 2 port valve manifold block assembly Manifold block assembly for gate valve D: 3 port valve manifold block assembly M4
4 M4 4 AS-45B AS-42B AS-44B AS-47B AS-46B Precautionswhenoptionsareordered ThreadedstudsformanifoldarenotincludedwhenL-bracketandDINrailmountingbracketareordered.Pleaseorderthemaccordingtothenumberofstations.
Maintenance Caution Supply Pressure qAfter removing the 4 mounting screws (M4 X 8) pull the switch body off vertically. If the switch body is pulled off in an angle the connector pins may be bent. wWhen mounting the switch body onto the base, be careful that the body is lowered vertically onto the base and the connector pins are not bent. Tighten the 4 mounting screws equally (M4 X 8).
Transfer fluid 19 Process Pump Built-in Solenoid Valve Type/Air Operated Type Series PB1000 Dimensions/Built-in Solenoid Valve Type/Air Operated Type PB1000 FLUID OUT Rc 1/8 11 OUT 11 84 72 Mount with this surface (OUT port side) on top 7.5 41 60 45 UP SIDE Mounting position MODEL PB1011 PROCESS PUMP 16 (78.1) SUPPLY PRESS AIR 0.2~0.7MPa VOLTAGE DC ON OFF 2-4.5 Mounting hole MADE IN JAPAN 2-M4
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com OUT 3 36 OUT 2 ZSP OUT 4 Left Right OUT 1 OUT 5 n Stations 1 ISA2 Stations L1 L2 L3 1 106 2 144 38 3 182 38 76 4 220 76 114 5 258 114 152 6 296 152 190 63 (Max. 65) IS ZSM 34 DC () OUT 6 5 17 DC (+) PF2 39 (With HW, SW) M4 x 8 Detection port 19 Rc
built-in solenoid valve type only) LVD LVQ AIR SUP (Pilot air supply port) Rc 1/8 LQ FLUID IN Rc 1/8 22 9 11 13 LVN SUP IN 11 TI/ TIL 18.5 32 PA EXH Foot bracket Option PAX 45 PB 2-M4 x 0.7 Female mounting threads Thread depth 6 AIR EXH (pilot air exhaust port) M5 x 0.8 Thread depth 10 The PB1013 air operated type has a plug. 17-5-167 28 Related Products: How to Order Process pump High