] 240 480 1200 10 0 -10% *1 Please consult with SMC for non-standard strokes as they are produced as special orders. *2 For details, refer to "Speed-Work Load Graph (Guide)" on catalog. *3 The allowable speed changes according to the stroke. *4 A reference value for correcting an error in reciprocal operation. *5 Impact resistance: No malfunction occurred when the actuator was tested with
Specifications 05 1 Size Basic type With external stopper Basic type With external stopper Fluid Air(Non-lube) Maximum operating pressure 0.7 MPa Minimum operating pressure 0.15 MPa Ambient and fluid temperature 060No freezing 8 10 8 10 100 , 90 90,180 100 , 90 90,180 0 0 0 0 Rotation angle 8 10 8 10 190 , 180 190 , 180 0 0 0 0 Angle adjustment range Each rotation end 5 Each rotation end
Structural Drawing, Option and Replacement Parts 10 6. Bowl Assembly Specifications 11-18 7. Assembly of Optional Parts 19 8. Operation and Adjustment 20-21 9. Trouble Shooting 22 10. How to Replace the Components 23-28 10-1. Bowl Assembly Replacement 23-25 10-2. Element Replacement 26-28 11. Disassembly Drawing 29 12.
ZSE1-00-14 ZSE1-00-15 ZSE1-00-16 ZSE1-00-17 ZSE1-00-18 ZSE1-00-19 ZSE1-00-55 Model -X129 (-X130) -X129 (-X130) -X129 (-X130) -X129 (-X130) -X129 (-X130) -X129 (-X130) -X129 (-X130) Sensor type Diffusion type semiconductor pressure sensor Set pressure range 0 to 101 kPa Hysteresis 1 to 10% of set pressure (Adjustable) 3% full span or less (Fixed) 1 to 10% of set pressure (Adjustable) 1% full
U side D side 40.2 15.5 46.2 19.4 A A 9.5 16.7 P = 10 n-M5 x 0.8 A port Dimensions Formula: L1 = 10n + 21, L2 = 10n + 7, n: Station (Max. 20 stations) n L L1 L2 2 41 27 3 51 37 4 61 47 5 71 57 6 81 67 7 91 77 8 9 10 121 107 11 131 117 12 141 127 13 151 137 14 161 147 15 171 157 16 181 167 17 191 177 18 201 187 19 211 197 20 221 207 1 31 17 101 87 111 97 4-12-15 Series VQ100 Manifold Option
L . 10-1 10.1 . 10-1 10.2 . 10-1 10.3 . 10-2 10.4 . 10-2 11 R .11-1 11.1 . 11-1 11.2 . 11-1 11.3 . 11-2 12 T . 12-1 12.1 . 12-1 12.2 . 12-1 12.3 . 12-2 12.4 . 12-3 12.5 . 12-4 13 V . 12-5 13.1 . 13-1 13.2 . 13-1 13.3 . 13-2 14 . 14-1 14.1 . 14-1 IDF60/70/80/90 Series IDX-OM-W093 1 1.1 () 6.2 1.1.1 3 IDF60/70/80/90 Series 1-1 IDX-OM-W093 1.2 6 1.2.1 1.2.2 50 1.2.3
AWM20-D AWM30-D AWM40-D (1) Bracket assembly Note 1) AW23P-270AS AR33P-270AS AR43P-270AS (2) Set nut AR23P-260S AR33P-260S AR43P-260S G36-10-01 Rc G46-10-01 Pressure gauge Note 2) G36-10-N01 G46-10-N01 NPT (Round type) G36-P10-N01-X30 Z : Both in MPa and psi G46-P10-N01-X30 (3) G36-10-01 G G46-10-01 G36-10-01-L Rc G46-10-01-L Pressure gauge Note 2) G36-10-N01-L NPT G46-10-N01-L (Round type
AWD20-D AWD30-D AWD40-D (1) Bracket assembly Note 1) AW23P-270AS AR33P-270AS AR43P-270AS (2) Set nut AR23P-260S AR33P-260S AR43P-260S Rc G46-10-01 G36-10-01 G36-10-N01 G46-10-N01 Pressure gauge Note 2) NPT (Round type) G36-P10-N01-X30 Z : Both in MPa and psi G46-P10-N01-X30 (3) G36-10-01 G G46-10-01 G36-10-01-L Rc G46-10-01-L Pressure gauge Note 2) G36-10-N01-L NPT G46-10-N01-L (Round type
10 0 0 10 30 40 50 20 60 10 20 Discharge rate l/min Discharge rate l/min 1m = 3.28ft 1l/min = 0.035SCFM Selection from flow rate characteristic graphs (PA3000) Required specification example: 3.
For precise pressure detection, allow the product to warm up for 10 to 15 minutes. Check if the product satisfies the specified accuracy 10 minutes after supplying power. Warming up inadequate Product failure Replace the product. Unit s selection function is not available for fixed to SI units type.
4 x M4 x 0.7 through (Thread for mounting attachment) 34 10 When open G (mm) J 24 39 57 H 116 158 196 G 92 134 172 F 72 94 112 E 26 42 60 D 67 83 101 B C 36 52 70 A MHL2-10D MHL2-10D1 MHL2-10D2 11221122112296 124 162 38 54 72 MHL2-16D 1122A B C +0.025 3H9 0 depth 3 D 2 x M5 x 0.8 thread depth 7 (Mounting thread) 10 2 x 5.5 through (Hole for mounting body) 42 When closed E When closed J 4
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 4 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 5 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low tank fluid level 1 CH1 abnormal high circulating fluid temp. 2 Reservation
No.1 OFF ON P2 No.2 OFF ON P3 No.3 OFF ON P4 No.4 OFF ON P5 P6 P7 P8 7 8 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 50 13 14 15 16 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 51 F : 2019 1 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +
Slider type LEKFS series 2.1 Specification AC servo motorMotor typeS*/T*) Model LEKFS25 LEKFS32 LEKFS40 Stroke [mm] 100 to 500 100 to 500 200 to 600 Horizontal 10 20 20 30 40 45 30 50 60 Work load [kg] Note1) Vertical 4 8 15 5 10 20 7 15 30 Up to 400 1500 900 450 1500 1000 500 1500 1000 500 401 to 500 1200 720 360 1500 1000 500 1500 1000 500 501 to 600 900 540 270 1200 1000 500 1500 1000
CN2: TB/PC connector.31 9. 1 How to use.31 10. LED display.32 10. 1 LED display.32 10. 2 Controller IF communication status and LED display.33 11. Mode.34 11. 1 Outline.34 11. 2. Step data input mode .34 11. 3. Numerical data input mode.34 11. 4. Data writing mode.36 12.
Check if the product satisfies the specified accuracy 10 to 15 minutes after supplying power. Output will drift after the power was supplied. Wait for 10 to 15 minutes for warming up. Warming up inadequate Incorrect wiring and incorrect load specification Check if a correct load is connected to the analogue output.
to 1000 L/min 20 to 2000 L/min Instantaneous flow 5 to 525 L/min 10 to 1050 L/min 20 to 2100 L/min Set flow rate range Accumulated flow 0 to 999,999,990 L Instantaneous flow 1 L/min Flow Minimum setting unit Accumulated flow 10 L Accumulated volume per pulse (Pulse width = 50 msec.) 1 L/pulse 10 L/pulse Accumulated value hold 1 Every 2 minutes or every 5 minutes Rated pressure range 0 to
Bore size Standard stroke (inch) Max. stroke (inch) (mm) (inch-Nominal) 2, 3, 4, 5, 6, 8, 10 2, 3, 4, 5, 6, 8, 10 5, 10, 15, 20, 25, 30 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 5, 10, 15, 20, 25, 30, 40 1/4" 6 12 3/8" 10 20 5/8" 15 40 3/4" 20 60 1" 25 80 1-1/4" 32 80 1-1/2" 40 80 2" 50 80 2-1/2" 63 80
Please order 10 sets at a time. 2.9-14 Series VQ100 Manifold Option Manifold Option VV3Q11 For Manifold With Multi-connector Plug Assembly VVQ100-12A1 2 3 D Side End Plate Assembly Finishing O.D. 7.8 D side end plate assembly part number VVQ100-3A-l SY qw e Option Cover color: Ivory 1 2 Standard DIN rail mounting SYJ 1 4 17 10 5 11 16 17 20 VK U Side End Plate Assembly L 52 30 10 U side end
Symbol 10 20 30 40 50 60 Body size Description Metric thread (M5) Rc NPT G Nil Thread type N Note 1) F Note 2) + M5 01 02 03 04 06 10 M5 1/8 1/4 3/8 1/2 3/4 1 Port size + Nil B Note 3) Mounting a Without mounting option With bracket + Semi-standard Option Nil C D Float type auto drain b Without auto drain Float type auto drain (N.C.)