Body Size: 40 (Applicable AC Size: AC40), Handle Operation: Single Action, Thread Type: F (G), Port Size: 06 (3/4), Mounting: B (w/Bracket), Silencer: without Silencer, Handle Color: Red, Handle Material: M (Metal), Flow Direction: Flow Direction: Left to Right), Unit: Unit of Product Label: MPa
Body Size: 20 (Applicable AC Size: AC20), Handle Operation: Single Action, Thread Type: Rc, Port Size: 01 (1/8), Mounting: B (w/Bracket), Silencer: S (w/Built-in Silencer, EXH Port), Handle Color: Red, Handle Material: M (Metal), Flow Direction: Flow Direction: Left to Right), Unit: Unit of Product Label: MPa
Body Size: 40 (Applicable AC Size: AC40), Handle Operation: Single Action, Thread Type: Rc, Port Size: 04 (1/2), Mounting: B (w/Bracket), Silencer: S (w/Built-in Silencer, EXH Port), Handle Color: Red, Handle Material: M (Metal), Flow Direction: Flow Direction: Left to Right), Unit: Unit of Product Label: MPa
Lightweight, point-of-use ZH and ZU series vacuum generators combine design simplicity with high performance. Simply plug an air supply tube in one end, and vacuum is ready at the other end. The slim ZU generators are extra compact. The ZH and ZU immediate response may be quicker than central vacuum systems. Also, these generators are often smaller and lighter than the bulky vacuum lines
Part Number Description: VACUUM EJECTOR (EURO) Product Line: Z Product Line Description: VACUUM SERIES Family Code: 600 Family Description: ZH VACUUM EJECTOR Class Code: C7 Part Code: 1 Reference Code: J Click here to report information errorImage shown may not match exact part number, ModelConnection (One-touch/Screw-in) SUPVACEXHZH10B?6/Rc 1 8?6/Rc 1 8?
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VACUUM EJECTOR, VACUUM SERIES, ZH VACUUM EJECTOR, CC, ZH NOZZLE SIZE 1.0, .15401 lb, ModelConnection (One-touch/Screw-in) SUPVACEXHZH10D?6/Rc 1 8?6/Rc 1 8?8/Rc 1 8
SMC's PFM dual color digital flow switch was?developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications.? The series is incredibly compact and lightweight compared to existing flow sensors.??The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, DIGITAL FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, CA, IFW/PFW 1/8INCH PT VERSION, 0.55115 lb
SMCs PFM dual color digital flow switch was?developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications.? The series is incredibly compact and lightweight compared to existing flow sensors.??The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon
SMC's PFM dual color digital flow switch was developed initially to detect microchip component adsorption in vacuum, and early clogging in both filter and nozzle applications. The series is incredibly compact and lightweight compared to existing flow sensors. The PFM is available in four maximum flow rate options 10, 25, 50 and 100 /min, and is suitable for use with air, nitrogen, argon
Body Size: 20, Thread: G, Port Size: 1/8, Option: w/o Bracket; w/o Auto Drain, Semi-Standard 1: C + R, Semi-Standard 2: Standard, Made to Order: -
Body Size: 20, Thread: G, Port Size: 1/8, Option: w/o Bracket; w/o Auto Drain, Semi-Standard 1: 2 + R, Semi-Standard 2: Standard, Made to Order: -
Flow Rate Range: 10 [0.2 to 10 (5 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: Panel Mount Adapter for w/Flow Adjustment
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: E [1 PNP Outputs + Analog (1 to 5 V)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: None, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/o Flow Adjustment
Flow Rate Range: 50 [1 to 50 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/Flow Adjustment
Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: -, Option: -
Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: F [1 PNP Outputs + Analog (4 to 20 mA)], Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: -
Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: -
Flow Rate Range: 25 [0.5 to 25 (25 for CO2) ℓ/min], Flow Adjustment Valve: Yes, Port Size: G1/8, Piping Entry Direction: Straight, Output Specification: 2 PNP Outputs, Unit Specification: Unit Switching Function, Instruction Manual: With Instruction Manual, Calibration Certificate: None, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/Flow Adjustment Valve