Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: SI Unit Only, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: Operation Manual, Calibration Certificate
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: None, Operation Manual: Operation Manual, Calibration
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation Manual
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: None, Operation Manual: Operation Manual, Calibration Certificate
Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: -
Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: w/o Lead Wire, Bracket: Panel Mount Adapter + Front Protection Cover, Operation
Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Panel Mount Adapter + Front Protection Cover
Rated Vacuum Range: -100 to 100 kPa, Output Specification: NPN Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Bottom Ported, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: -, Operation
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: w/o Lead Wire, Bracket: Panel Mount Adapter, Operation Manual: -
The series is available in six size options with a wide range o, BODY ASSY (NAF3000-N02), AIRLINE EQUIPMENT, AF FILTER, D2, AF 1/4INCH KIT/ACCESSORY, 0.638 lb
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: E (Panel Mount Adapter)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: Rear Ported, Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
-10 AS221FG-N01-07 23.9 31 21 21 32.1 14.1 39.2 10 18.5 1/4" 13.2 17 19 AS221FG-02-04 AS221FG-N01-09 14.1 25.3 32.4 16 25.2 34.4 4 10.4 5/16" 15.2 18.5 21 32 AS221FG-02-06 AS221FG-N02-03 25.2 34.4 17 25.2 17.7 34.4 6 12.8 5/32" 10.4 16 18.5 29.4 34.9 39.9 17 34.4 R 1/4 32 AS221FG-02-08 AS221FG-N02-05 17.7 24.9 34.2 34 18.5 27.2 36.4 8 15.2 3/16" 11.4 16.5 NPT 1/4 AS221FG-02-10 AS221FG-N02
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MECHANICAL, VALVE, VM (VFM/VZM) MECHANICAL VALVE, FA, VM BODY PT 1/4, .63934 lb
Series VFM is a 5 port, compact, mechanical valve available in a rubber (VFM300) or metal (VFM200) seal style. This series has a large flow capacity (Cv 1.0) and a high cycle rate. The VFM offers an internal or external pilot body option and a variety of actuator choices.Fluid: air, inert gas, Operating pressure range: 0.15 to 0.9MPa, Effective area (Cv): 18mm 2 (1.0), Maximum frequency
Series VFM is a 5 port, compact, mechanical valve available in a rubber (VFM300) or metal (VFM200) seal style. This series has a large flow capacity (Cv 1.0) and a high cycle rate. The VFM offers an internal or external pilot body option and a variety of actuator choices.Fluid: air, inert gas, Operating pressure range: 0.15 to 0.9MPa, Effective area (Cv): 18mm 2 (1.0), Maximum frequency
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, MECHANICAL, VALVE, VM (VFM/VZM) MECHANICAL VALVE, FA, VM BODY PT 1/4, .68342 lb