C 8 8 8.5 8.5 D 50 60 50 60 75 85 75 85 85 95 75 85 95 130 100 130 Mounting bolt M3 X 50l M3 X 60l M3 X 50l M3 X 60l M5 X 75l M5 X 85l M5 X 75l M5 X 85l M5 X 85l M5 X 95l M5 X 75l M5 X 85l M6 X 95l M6 X 130l M8 X 100l M8 X 130l MKB12-10 MKB12-20 MKB16-10 MKB16-20 MKB20-10 MKB20-20 MKB25-10 MKB25-20 MKB32-10 MKB32-20 MKB40-10 MKB40-20 MKB50-20 MKB50-50 MKB63-20 MKB63-50 PTo attach and detach
Full stroke 5 10 10 15 15 15 20 20 15 2 pcs.
L 10-1 . 10-1 10-2 . 10-1 10-3 (ADH4000-04) . 10-2 10-4 . 10-2 10-5 . 10-2 11 11-1 . 11-1 11-2 . 11-1 11-3 . 11-1 11-4 . 11-2 11-5 . 11-2 12 T 12-1 . 12-1 12-2 . 12-1 12-3 . 12-2 12-4 . 12-2 12-5 . 12-3 13 V 13-1 . 13-1 13-2 . 13-2 13-3 . 13-2 14 14-1 . 14-1 IDFA Series 2 IDX-OM-W017 i i i 1 () OFF 3 ON OFF i-1 IDFA Series i 1 IDX-OM-W017 i i-1-1 3 IDFA Series
Metric sizes 06 10 12 19 6 10 12 19 1/4 3/8 1/2 3/4 Inch sizes 07 11 13 19 Variations LVD20-T Model LVD30-T LVD40-T LVD50-T Orifice diameter 4 8 10 16 Tubing O.D. Metric 6 10 12 19 Inch Valve type Type Symbol 1/4 3/8 1/2 3/4 Basic type N.C. PA PB PA N.O. B A B A PB B A N.C. N.O. Double acting Double acting With flow rate adjustment N.C. PA PA B A B A PB Double acting N.C.
(FKM) 1.3 x 10-8 Internal 1.3 x 10-10 (FKM) 1.3 x 10-8 DNil A B C Seal material XSA Symbol Nil N1 1.3 x 10-8 1.3 x 10-10 (FKM) 1.3 x 10-8 Seal material FKM EPDM Barrel Perfluoro Compound no. 1349-80 2101-80 1.3 x 10-10 (FKM) XVD Note 1) Values at ambient temperatures, excluding gas permeation.
Metric System (g) = 105.5 meters per sec. per sec NewtonMeters KilopondMeters Foot-lbs Inch-lbs 3 3 1.020 x 10 -1 7.376 x 10 -1 8.851 1 3 7.233 3 3 1 3 86.80 0.01 3 1.382 x 10 -1 1 3 12 3 1.356 1.130 x 10 -1 1.52 x 10 -2 8.333 x 10 -2 1 3 Length (Linear Measurement) Meter Centimeter Kilometer Mile Inch Foot 3 100 3 1x10 4 6.214x10 -4 39.370 3 3.281 3 1 3 1 3 1x10 5 6.214x10 -6 3.937x10 -1
Metric System (g) = 105.5 meters per sec. per sec NewtonMeters KilopondMeters Foot-lbs Inch-lbs 3 3 1.020 x 10 -1 7.376 x 10 -1 8.851 1 3 7.233 3 3 1 3 86.80 0.01 3 1.382 x 10 -1 1 3 12 3 1.356 1.130 x 10 -1 1.52 x 10 -2 8.333 x 10 -2 1 3 Length (Linear Measurement) Meter Centimeter Kilometer Mile Inch Foot 3 100 3 1x10 4 6.214x10 -4 39.370 3 3.281 3 1 3 1 3 1x10 5 6.214x10 -6 3.937x10 -1
44 42.5 44 41 23.5 43 14.5 41 6.5 23.5 REBR32 19.5 11 6.5 3 1.5 35 10.5 16 55 53.5 55 52 29 54 20 51 7 29 K L LD M N P PW QW T TC W WP J x E Q MM Model REBR15 14 53 4.3 5 6 M5 x 0.8 32 18 21 17 25 M5 x 0.8 x 7 84 M4 x 0.7 REBR25 15 70 5.6 6 6.5 Rc 1/8 43 20 25.5 22.5 40 21.5 M6 x 1 x 8 105 M5 x 0.8 REBR32 13 76 7 7 8.5 Rc 1/8 54 26 33 28 50 27 M8 x 1.25 x 10 116 M6 x 1 X Y Z Model REBR15
For precise pressure detection, allow the product to warm up for 10 to 15 minutes. Check if the product satisfies the specified accuracy 10 minutes after supplying power. Warming up inadequate Product failure Replace the product. -64No.PS-OMU0012-C Problem No.
The power supply voltage between the power supply terminal PWR_24V and PWR_GND is outside of DC24 V +/10%. Power supply Use a power supply voltage of DC24 V+/-10%. PWR LED: error PWR signal: 1 Green flashing Continue OFF (Outside of 24 (Cycle: 1 Hz) V+/-10%) The power supply voltage between the power supply terminal PWR_24V and PWR_GND is below 17 V.
Specifications Model MSUA1 MSUA3 MSUA7 MSUA20 Vane Type Single vane Rotating angle *1) 90 o 180 o 90 o 180 o 90 o 180 o 90 o 180 o +/10 o +/10 o +/10 o +/10 o +/10 o +/10 o +/10 o +/10 o Fluid Air (Non-lube) Proof pressure 1.05 MPa 1.5 MPa Ambient and fluid temperature 5 to 60 oC Operating pressure range 0.2 to 0.7 MPa 0.15 to 0.7 MPa 0.15 to 1.0 MPa Rotation time adjustment range 0.07 to
) 2) 1) 14 to 194F (10 to 90C) for Vespel and PEEK seat.
Wiring 41 7.4. Process data 41 7.5. LED indicators 42 7.6. Block diagram 43 8. Digital Output Module EX245-DY1 44 8.1. Parts and description 44 8.2. Specifications 45 8.3. Wiring 46 8.4. Process data 46 8.5. LED indicators 47 8.6. Block diagram 48 -2No.EX##-OMU0020-A 9. End Plate EX245-EA2-1/2 49 9.1. Parts and description 49 9.2. Specifications 50 10. Accessories 51 10.1.
(g) Cylinder stroke (mm) Model 5 10 15 20 25 30 40 50 22 (27) 25 (35) 28 (38) 31 (41) 34 (44) 37 (47) C(D)U6-D When mounting Series CU, refer to the below table. Tightening Torque/ 36 (41) 40 (50) 44 (54) 48 (58) 52 (62) 56 (66) Bore size (mm) Hexagon socket head cap screw dia.
Display/set pressure range -2.5 to 52.5 MPa Display/min. set unit 0.1 MPa Proof pressure 75 MPa Power supply Used as switch output device 12 to 24 VDC 10% with 10% voltage ripple or less voltage Electric spec.
For a 10 orifice (VXS23/Port size 1/4), P 0.05 MPa The optimum size for a pressure differential of P 0.2 MPa and a flow of 50 L/min will be the VXS23 (10 orifice, port size 3/8). 500 400 VXS26 25 Cv = 12 300 VXS25 20 Cv = 9.2 200 VXS24 15 Cv = 5.3 Flow rate Q [L/min] 100 VXS23 Port size 3/8 10 Cv = 2.8 VXS23 Port size 1/4 10 Cv = 2.4 50 40 30 25 20 10 0.01 0.02 0.03 0.04 0.05 0.1 0.2 0.3
to 1000 L/mim 20 to 2000 L/mim Instantaneous flow 5 to 525 L/mim 10 to 1050 L/mim 20 to 2100 L/mim Set flow rate range Accumulated flow 0 to 999,999,990 L Instantaneous flow 1 L/min Flow Minimum setting unit Accumulated flow 10 L Accumulated volume per pulse (Pulse width = 50 msec.) 1 L/pulse 10 L/pulse Accumulated value hold 2 Every 2 minutes or every 5 minutes Rated pressure range 0 to
Powet Preflx Svmbol Pourer Preflx Svmbol 10-1 deci d 101 Deka da fi2 Heclo h 1O-2 centi c iO-3 milli m 103 Kilo k 10-6 micro ], tO6 Mega M Table 3.2 Prefixes tor powers of ten This lads us to a kPa (kilo-pascal or 1/100 b ol a BAR) and an MPa (1,OOO,OO0 pascals or 10 BAF). Practice with these prefixes and pay attention to what th symbol represents in terms of powers of ten.