Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting w/ Spring Loaded, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 1.0, Port thread type: Rc, Body Options: With lock mechanism, with cancel cap, Auto
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 1.0, Port thread type: Rc, Body Options: With lock mechanism, with cancel cap, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 1.0, Port thread type: Rc, Body Options: With lock mechanism, with cancel cap, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 1.0, Port thread type: NPT, Body Options: With lock mechanism, with cancel cap, Auto Switches: Without
SI 4 x M12, 5 way, Sockets 24V(UT1) DI(n+1) Sensor interface 0V DI(n) 24V(UT2) Push Pull connector (24 Volt) 24V(US1) 0V(US1) 0 V (M OUT) 1 Power 24V(US2) 0V(US2) 0 V (M OUT) 2 DC / DC FE Safe 24V (ZONE OUT 1) 3 Output circuit OUT [0] 4 Push Pull connector (24 Volt) Safe 24V(US1) Input circuit 0V(US1) Power 24V(US2) OUT [7] 11 0V(US2) 24V (ZONE OUT 2) 12 FE Internal 13 OUT
PF-OMK0003CN-E FG DC(+) OUT() DC(-) 15V 1k -17No. PF-OMK0003CN-E DC(+)DC(+) (OUT1) IN (20 ) -18No.
Connector Pin numbers (on the lead wire) Pin number Content Colour 1 DC(+) Brown 2 OUT2 White 3 DC(-) Blue 4 OUT1 Black -17No.PF-OMO0008-C Internal circuit and wiring example When the lead wire with connector designated for the PF2A7 is used, the wire colours will apply as shown in the diagram.
Connector Pin numbers (on the lead wire) Pin number Content Colour 1 DC(+) Brown 2 Analogue output White 3 DC(-) Blue 4 OUT1 Black -16No.PF-OMG0010-H Internal circuit and wiring example When the lead wire with connector designated for the PF2A7 is used, the wire colours will apply as shown in the diagram.
Connector Pin numbers (on the lead wire) Pin number Content Colour 1 DC(+) Brown 2 N.C./Analogue output White 3 DC(-) Blue 4 Output for PF2A3 Black Connecting the wiring How to connect the body and the lead wire and connector Align the lead wire connector with the connector key groove, and insert vertically. Connection is complete when the knurled part is fully tightened.
Description 1 DC(-) (for sensor) 2 DC(+) (for sensor) 3 Sensor input 4 N.C. 5 DC(-) (supply voltage) 6 DC(+) (supply voltage) 7 OUT1 8 OUT2 -16No.PF-OMG0008-F Internal circuit and wiring example Use sensor PF25 series for accurate measurement.
ZS-28-CA-4 Sensor connector 1 pc. -11No.PF-OMO0014-D Summary of Product parts Connector pin numbers (on the product) 1 DC(+) 2 N.C./Analogue output 3 DC(-) 4 Output for PF2W3 Item Description Lead wire and connector Lead wire to supply power and transmit output signals. Connector Connector for electrical connections.
power supply of this product, make sure that the total load current is 500 mA or less. *2 Refer to "3.3.6 Wiring of contact output signal" 3.3 Installation HRR Series 3-12 HRX-OM-X084 Chapter 3 Transport and Setting Up Table 3-6 Contact input/output pin number PIN no Application Division Initial value (Default setting) 1 DC 24V output Output 2 DC 24V output Output 3 DC 24V output Output
CEU2P COM Max DC +30V 50mA 26 7-3-5 3 +5V ABBR DC +24V 80mA050 24E DC24V +24V COM (+) U (-) VAL.OUT 24E (ABBR) 7-3-6 50msec 50msec 27 8
Signals name: Position Detected, Origin Calculated, Program END, Error Maximum terminal Voltage: DC+30V Maximum Current : 50mA (0~50) Output Internals Circuit Connection Method Model Controller: CEU2 NPN Output Transistor OUT Max DC + 30V , 50mA Load CEU2 COM Controller: CEU2P PNP Output Transistor OUT Load CEU2P COM Max DC + 30V , 50mA 35 9-3-5 Solenoid Valves Wiring Solenoid valve driving
N No. 6 7 8 9 1 0 0 0 0 2 1 0 0 0 3 0 1 0 0 4 1 1 0 0 5 0 0 1 0 6 1 0 1 0 7 0 1 1 0 8 1 1 1 0 9 0 0 0 1 10 1 0 0 1 11 0 1 0 1 12 1 1 0 1 13 0 0 1 1 14 1 0 1 1 15 0 1 1 1 16 1 1 1 1 0IN69 COM 1IN69 COM No.1 ON OFF 1 2 50msec 34 9-3-3 INPUT 13 +24V +5V /12 3412 +5V +24V IN 10mA COM 10mA 9-3-4 OUTPUT 4 5V END DC +30V 50mA050 CEU2 NPN OUT Max DC +30V 50mA CEU2 COM CEU2P PNP OUT
For compressed air quality, refer to SMCs Best Pneumatics When connecting power to a solenoid valve with a DC specification and equipped with a light or surge voltage suppressor, check for polarity. If polarity connection is wrong, the valve does not operate. 2. Applied voltage catalog. 4. Use clean air.
Caution Apparent power Holding18VA50Hz Coil rated voltage (V) AC50/60Hz 100, 110, 200, 220 DC 12, 24 2. Vacuum type [VT/O 315V] If the solenoid valve is mounted on a metal surface, it can breathe through the breathing hole. However, if the valve is to be mounted on a surface made of rubber, it could deform and block the breathing hole.
DC (With surge voltage suppressor) Red (+), Black () Other Gray Engagement mark For "Nil: W/O light/surge voltage suppressor" with DC specification, there is no polarity. Normal condition (Unlocked) Valve Option 1.
Connect the 0 V DC wire (blue line) directly or as close as possible to the 0 V DC terminal of the DC power supply. -5No.SFOD-OMO0004-B The direct-current power supply to combine should use UL authorization power supply which is the class 2 power supply based on UL 1310 or the power supply is using the transformer of a class 2 based on UL 1585.
Faults and countermeasures Fault Status Possible cause Item to check Countermeasure Check that the brown and blue wires are connected to DC (+) and DC (-) respectively. Incorrect wiring Correct the wiring. Indicator LED does not turn ON Loose connector Check the connectors. Correct the connector wiring.