Nominal thread size Required torque Rc(NPT)1/8 7 to 9 Nm Rc(NPT)1/4 12 to 14 Nm Rc(NPT)3/8 22 to 24 Nm Rc(NPT)1/2 28 to 30 Nm Model Width across flats of attachment PF2A510 24 mm PF2A550 PF2A511 30 mm PF2A521 PF2A551 -15No.PF-OMO0010-C Wiring Connections should only be made with the power supply turned off. Use separate routes for the product wiring and any power or high voltage wiring.
Nominal thread size Required torque Rc(NPT)3/8 22 to 24 Nm Rc(NPT)1/2 28 to 30 Nm Rc(NPT)3/4 28 to 30 Nm Rc(NPT)1 36 to 38 Nm Model Width across flats of attachment PF2W504 34 mm PF2W520 PF2W540 PF2W511 45 mm PF2W504T 34 mm PF2W520T PF2W540T -16No.PF-OMO0014-D Wiring Connections should only be made with the power supply turned off.
Nominal thread size Appropriate tightening torque Rc(NPT)3/8 22 to 24 Nm Rc(NPT)1/2 28 to 30 Nm Rc(NPT)3/4 28 to 30 Nm Rc(NPT)1 36 to 38 Nm If the tightening torque is exceeded, the product can be damaged. If the tightening torque is insufficient, the mounting screws and brackets may become loose. The product body is made of resin.
(NPT)3/8 2224 Nm Rc(NPT)1/2 2830 Nm Rc(NPT)3/4 2830 Nm Rc(NPT)1 3638 Nm NG NG 19 No.LFE*-OMY0008 NG IN 5 (5D)(68 ) 20 No.LFE*-OMY0008 FG 3 1 DC() 4 2 2 OUT2 3 DC() 1 4 OUT1 3 4 2 1 DC() 2 OUT2 3 DC() 1 4 OUT1 LFE M12 21 No.LFE*-OMY0008 NPN2 LFEA PNP2 LFEB DC() OUT1 OUT2 DC() OUT1 DC24V DC24V DC() DC() Max.28 V80 mA 1 V Max.80 mA 1.5 V NPN LFEC NPN LFED DC() OUT1 OUT2 DC() OUT1
Nominal thread size Appropriate tightening torque Rc(NPT)3/8 22 to 24 Nm Rc(NPT)1/2 28 to 30 Nm Rc(NPT)3/4 28 to 30 Nm Rc(NPT)1 36 to 38 Nm If the tightening torque is exceeded, the product can be damaged. If the tightening torque is insufficient, the piping may become loose. The product body is made of resin.
Connection thread Proper tightening torque (Nm) Port name Rc, NPT, G 1/4 1214 AIR SUP, AIR EXH Rc, NPT, G 1/2 22.5 FLUID IN, FLUID OUT Rc, NPT, G 3/4 45 6 4. Air Supply Warning 1. Use clean air. Do not use compressed air that includes chemicals, synthetic oils containing organic solvents, salinities or corrosive gases, etc., as it can cause damage or malfunction. 2.
Connection thread Proper tightening torque (Nm) Port name Rc, NPT, G 1/4 1214 AIR SUP (P1, P2) Rc, NPT, G 1/2 22.5 FLUID IN, FLUID OUT Rc, NPT, G 3/4 45 6 4. Air Supply Warning 1. Use clean air. Do not use compressed air that includes chemicals, synthetic oils containing organic solvents, salinities or corrosive gases, etc., as it can cause damage or malfunction. 2.
This may cause internal damage to the process pump or liquid leakage. 10 Specifications Model PA3310 PAP3310 Actuation Automatically operated Rc, NPT, G, NPTF 3/8" Female thread Main fluid suction discharge port Rc, NPT, G, NPTF 3/8" 3/8", 1/2" Tube extension Female thread With nut (size 3, 4, 5) 3/8", 1/2" Integrated fitting type Port size Pilot air supply/exhaust port Rc, NPT, G, NPTF 1
(with a handle) *2 : Unit : MPa/ C(degree Celsius) Piping thread type Power supply 20 3phase 200VAC(50Hz) Nill Rc 3phase 200 to 230VAC(60Hz) F G (Rc-G thread adapter set is included) 40 3phase 380 to 415VAC(50/60Hz) N NPT (Rc-NPT thread adapter set is included) 46 3phase 380 to 415VAC(50/60Hz) 3phase 460 to 480VAC(60Hz) Fig. 2-1 Product model number HRS Series 2.1Model number of product 2
A 46 400 HRS Cooling capacity 400 38kw Cooling method A Air-cooled refrigeration Piping thread type Nil Rc F G (Rc-G thread adapter set is included) N NPT (Rc-NPT thread adapter set is included) Power supply 40 3phase AC380-415V(50/60Hz) 3phase AC460-480V(60Hz) Option Nil None A Caster-adjuster foot installed D With electric conductivity control K Fluid fill port M Applicable to DI water
Piping thread type Nil Rc F G (Rc-G thread adapter set is included) *3Power supply '-20' only. *4W: Water-cooled only. N NPT (Rc-NPT thread adapter set is included) *5 Unit : MPa/ C (degree Celsius) *6 HRSH300-A-20/40 Air cooled only.
A 20 HRL Cooling capacity CH1 CH2 100 9 kw 1 kw 200 19 kw 1 kw 300 26 kw 1 kw Cooling method A Air-cooled refrigeration Piping thread type Nil Rc F G (Rc-G thread adapter set is included) N NPT (Rc-NPT thread adapter set is included) Power supply 20 AC200V/200-230V(50/60Hz) 3phase Fig. 2-1 Product model number HRL Series 2.1 Model Number of Product 2-1 HRX-OM-W060 Chapter 2 Name and Function
A 20 HRL Cooling capacity CH1 CH2 100 9 kw 1 kw 200 19 kw 1 kw 300 26 kw 1 kw Cooling method A Air-cooled refrigeration Piping thread type Nil Rc F G (Rc-G thread adapter set is included) N NPT (Rc-NPT thread adapter set is included) Power supply 20 3phase AC200V(50Hz) 3phase AC200-230V(60Hz) Option Nil CH2 Electric conductivity control D1 CH1,CH2 Electric conductivity control Fig. 2-1 Product
Refer to 1.4 Product Label" and check the part number of the product. 200 S A 46 HRS Cooling capacity Option 2 200 20kW None Nill Fixed SI unit W*2 Cooling method A Air-cooled refrigeration *2Unit: MPa/ oC (degree Celsius) Option 1 Piping thread type None Nill Nil Rc Caster-adjuster foot installed A F G (Rc-G thread adapter set is included) Fluid fill port K*1 N NPT (Rc-NPT thread adapter
Connection of fittings Rc types Tighten with the proper torque shown below. Tightening Torque for Piping Caution Caution Connection Proper tightening Proper tightening torque (N m ) thread Rc 1/4 8 to12 Rc 3/8 15 to 20 Rc 1/2 20 to 25 Rc 3/4 28 to 30 Mounting Follow the procedure of the manufacture when fittings other than SMC is used. 5.
Nominal thread size Appropriate tightening torque Rc(NPT)3/8 22 to 24 Nm Rc(NPT)1/2 28 to 30 Nm Rc(NPT)3/4 28 to 30 Nm Rc(NPT)1 36 to 38 Nm If the tightening torque is exceeded, the product can be damaged. If the tightening torque is insufficient, the mounting screws and brackets may become loose. The product body is made of resin.
AC20C-D to AC40C-D 30 03 DE AC C D Symbol Description Body size 20 30 40 Rc Nil Thread type NPT N G F 1/8 1/4 3/8 Port size 01 02 03 3/4 1/2 04 06 Nil Without auto drain a Float type auto drain C N.C. (Normally closed) Drain port is closed when pressure is not supplied. D N.O. (Normally opened) Drain port is opened when pressure is not supplied.
Nominal thread size Required torque Rc(NPT)3/8 22 to 24 Nm Rc(NPT)1/2 28 to 30 Nm Rc(NPT)3/4 28 to 30 Nm Rc(NPT)1 36 to 38 Nm Model Width across flats of attachment PF2W704 34 mm PF2W720 PF2W740 PF2W711 45 mm PF2W704T 34 mm PF2W720T PF2W740T -17No.PF-OMO0012-E Wiring Connections should only be made with the power supply turned off.
Note 8) Grommet value. 10 XSA-OMS0001-A Fluid property Face seal fitting / compression fitting XSA1-12 XSA1-22 XSA2-22 XSA2-32 XSA2-43 XSA3-32 XSA3-43 C [dm3/(sbar)] 0.55 1.07 1.07 1.51 2.78 1.54 2.89 b 0.41 0.36 0.34 0.24 0.21 0.24 0.21 (Rc, NPT) Threaded ports XSA1-11 XSA1-21 XSA2-22 XSA2-32 XSA3-33 XSA3-43 C [dm3/(sbar)] 0.54 1.14 1.14 2.23 2.37 3.5 b 0.36 0.39 0.42 0.38 0.40 0.15 3.
Rc 1/8 7 to 9 Rc 3/8 22 to 24 2. When there is a large amount of drainage. Rc 1/2 28 to 30 Compressed air containing a large amount of drainage can cause malfunction of pneumatic equipment. An air dryer or water separator should be installed upstream from filters. 6. Piping to products When piping to a product, avoid mistakes regarding the supply port, etc. 3.