YU-03 RS M W T2 V J E T1 B 2-D through K ( across flats) 2-O counter bore Joint H (with locking) d2 d1 mm Bore size (mm) B D E J M O Part no. L UT C UA 12 7 25 9 34 11.5, depth 7.5 YB-03 32, 40 12 9 32 11 42 14.5, depth 8.5 YB-05 50 mm Part no. Applicable bore size (mm) UA C d1 d2 H K L UT Weight (g) Weight (g) Bore size (mm) T1 T2 V W RS Part no.
Compact size (Width: 15 mm) Low power consumption: 1.8 W DC Fluid Air 0.15 to 0.7 0.1 to 0.7 0.15 to 0.7 10 to 50C (No freezing.
Rc C3SF-6J-A G C3SFF-6J-A Rc G C3SF-6-A NPT C3SFN-6J(Z)-A NPT C3SF-6(Z)-A Option symbol Semi-standard symbol W 6W Semi-standard: W Piping port thread ty pe (9) Part No. Rc G NPT C3SF-W(Z)-D C3SF-W-D Appearance and part No. Semi-standard: 6W Piping port thread ty pe (9) Part No.
Rc C3SF-6J-A G C3SFF-6J-A Rc G C3SF-6-A NPT C3SFN-6J(Z)-A NPT C3SF-6(Z)-A Option symbol Semi-standard symbol W 6W Semi-standard: W Piping port thread ty pe (9) Part No. Rc G NPT C3SF-W(Z)-D C3SF-W-D Appearance and part No. Semi-standard: 6W Piping port thread ty pe (9) Part No.
Replacement Differential pressure indicator Name Hydraulic fluid type Petroleum Water-glycol, Emulsion Phosphoric ester Differential pressure indication CB-50H CB-50H-V Differential pressure indication switch CB-51H CB-51H-V Blanking cap AG-12H AG-12H-W AG-12H-V Note 1) Refer to the Figure 2-1 for the assembly position.
50 or less Chloride ion (Cl) [mg/L] 50 or less Sulfuric acid ion (SO42) p p p p p [mg/L] 50 or less Acid consumption amount (at pH4.8) [mg/L] 70 or less Total hardness 1.Thoroughly read the Operation Manual.
R/W AoUt (Setting of analogue output) U8 0 Y 0: 1 to 5 V 10 to 10 V Setting of analogue output (Voltage output type only) 1 R/W FrEE (Setting of free range mode) U8 0 Y 0: oFF (Unused) 1: on (Used) Setting of free range mode 2110 0x083E Setting range 0x0190 to 0x1068 (400 to 4200) 2 R/W F_H (Set value of free range) S16 4000 Y Set value of free range Rated value 10% to 105% SAVE (Accumulated
fitting Sensor (Breathing port) PB H G C PA A B N E J B (F) R 2-V PB PA A B Pilot port threaded type (mm) Dimensions A B C D E F G H J K L M N P Q R V Model LVD1-S LVD2-S LVD3-S LVD4-S LVD5-S 4 (5/32") 20 20 45 39 9.5 46 23 11.5 4.5 11 30 5 21 28 22.5 M5 x 0.8 30 30 54.4 56 11 67 28.5 13 4 20 44 7 23 31.5 17 M5 x 0.8 6 35 35 79.5 62 17.5 83 45.5 14.5 6 22 50 7 37 6 36 21 M5 x 0.8 35 35 82
Insulation type Electrical entry Electrical option Class B G C D, T S Note) S L, Z 1 (100 V) 2 (200 V) 3 (110 V) 4 (220 V) 7 (240 V) 8 (48 V) 5 (24 V) 6 (12 V) AC DC Note) Surge voltage suppressor is attached in the middle of a lead wire. 17-3-72 3 The VX series will be revised shortly.
(Example: If the Pressure switch with output impedance of 1k is connected to the A/D converter to detect the analog output of 5V, the detected voltage by the A/D converter becomes 5(V) 1(M)/(1(k) + 1(M)) 4.995(V), and there is an error of approximate 0.005 V.) Output impedance P Peak hold mode Shows the maximum pressure reached at that moment.
V +24 V for SI unit operation LED Description 8 Mounting hole Mounting hole for connection to the valve manifold SI0 V 0 V for SI unit operation 4 SF System fault 5 Unused Accessories BF BUS fault Hexagon socket head cap screw 2 pcs.
24VDC10% Power [W] *4 Max. 57 Max. 51 Max. 123 Max. 141 Type *5 Non-magnetizing lock specification Lock unit Holding force [N] 20 39 47 78 157 72 108 216 75 113 225 Power consumption [W] *6 5 2.9 5 5 Power supply voltage [V] 24VDC10% *1 Speed changes according to the work load.
JIS Symbol Proportional Solenoid Specifications 1 A VEA25 Applicable power amplifier Max. current 13 (Ambient temperature 20C) Coil resistance 4(A) 4(A) 5(R1) 1(P) 3(R2) 5(R1) 1(P) 3(R2) 13 W (Ambient temperature 20C, with maximum current) Rated power consumption 2 (B) 2 (B) Coil insulation type Class H or equivalent (180C) Max. temperature rise 140C (Ambient temperature 50C, with maximum
V114-5LOU Electrical entry L shaped plug connector (L) Coil rated voltage [V] 24 Allowable voltage fluctuation -10 to 10% Power consumption [W] 0.4 [Starting 0.4,Holding 0.1] Surge voltage suppressor Varistor Indicator LED LED 19 - 4-3.
Display/set pressure range -0.105 to 1.050 MPa -0.105 to 1.680 MPa Display/min. set unit 0.001 MPa Proof pressure 1.5 MPa 2.4 MPa Power supply voltage 12 to 24 VDC 10% with 10% voltage ripple or less (p-p) Electric spec. Current consumption 35 mA or less Protection Polarity protection Accuracy Display accuracy 2%F.S.1 digit (at ambient temperature 253 oC) Repeatability 0.5%F.S.
V124 (A) 1 W (With indicator light: 1.1) Power consumption (W) DC 2 2 0.78 (With indicator light: 0.81) 100V 110V [115V] 0.86 (With indicator light: 0.89) 0.94 (With indicator light: 0.97) Apparent power (VA) AC 1.18 (With indicator light: 1.22) 200V 3 1 3 1 1.30 (With indicator light: 1.34) [1.42 (With indicator light: 1.46)] 220V [230V] Refer to page 647.
Weights Unit: g D-M9NW(V) D-M9PW(V) D-M9BW(V) Auto switch part no.
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N02 [NPT1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof)