Cooling Capacity: 250 (25kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: M (Applicable to DI Water Piping)
Cooling Capacity: 400 (38 kW), Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, with Rc-NPT Conversion Fitting), Power Supply: 46 (50/60Hz: 3-phase 380 to 415 VAC; 60Hz: 3-phase 460 to 480 VAC), Option: A (w/Caster Adjuster foot)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: J (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F), Bracket: None, Calibration Certificate: A (Calibration Certificate
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: J (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F), Bracket: None, Calibration Certificate: A (Calibration Certificate)
Its compact and space saving with an integrated flow adjustment valve.? The bypass structure?limits the contact of moist air with the sensor, reducing degradation?of the sensor and helps maintain accuracy.?
Thermo-chiller, Rack Mount, air cooled, CHILLER, 729, 40 lb
Thermo-chiller, Rack Mount, air cooled, CHILLER, 729, 40 lb
Thermo-chiller, Rack Mount, air cooled, CHILLER, 729, 40 lb
An angled supply port facilitates the supply of circulating fluid, even when units are?stacked.? A?large digital display provides a clear view of the current and set values.? The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS?
An angled supply port facilitates the supply of circulating fluid, even when units are?stacked.? A?large digital display provides a clear view of the current and set values.? The dustproof filter is integrated with the grill of the front panel allowing mounting and removal of the HRS?
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, HRS - NO SIZE RATING, OTHERS, HRS THERMO-CHILLERS, 2X, HRS - NO SIZE RATING, 94.79877 lb
Body Size: 10, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: M5, Option: Standard, Attachment: T (T-Interface), Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Standard
capacities: 1.3 kW, 1.7 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 100 VAC, 50/60Hz or 115 VAC, 60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018
capacities: 1.3 kW, 1.7 kW (at 60Hz); Temperature range setting: 5 to 40°C; Temperature stability: ±0.1°C; Power supply requirement: single phase 100 VAC, 50/60Hz or 115 VAC, 60Hz; Standards: CE, UL, RoHS; Circulating fluid: Tap water or 15% ethylene glycol, 30% Dowcal™100, ControXic 1642, Hexid A4, Coolflow IGE, NALCO®CCL105; SMC recommends Bypass Piping Set HRS-BP001 for Models HRS-012, HRS018
Protocol: D (DeviceNetâ„¢), Mounting: 8 (DIN Rail Mounting), Cable Connector: T (T-branch Type), Actuator: LEP, Type: S (Table Type), Body Size: 10, Motor Size: Basic, Lead: K (LEP*6: 4; LEP*10: 5), Stroke: 50mm
Protocol: D (DeviceNetâ„¢), Mounting: 8 (DIN Rail Mounting), Cable Connector: T (T-branch Type), Actuator: LEP, Type: Y (Rod Type), Body Size: 10, Motor Size: Basic, Lead: K (LEP*6: 4; LEP*10: 5), Stroke: 25mm
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, AMH 1 INCH STANDARD (PT), AIRLINE EQUIPMENT, AMH MICRO MIST SEPARATOR, HB, AMH 1 INCH STANDARD (PT), 10.08246 lb
Protocol: M (CC-Link), Mounting: 8 (DIN Rail Mounting), Cable Connector: T (T-branch Type), Actuator: LEP, Type: S (Table Type), Body Size: 10, Motor Size: Basic, Lead: K (LEP*6: 4; LEP*10: 5), Stroke: 50mm
Protocol: M (CC-Link), Mounting: 8 (DIN Rail Mounting), Cable Connector: T (T-branch Type), Actuator: LEP, Type: Y (Rod Type), Body Size: 10, Motor Size: Basic, Lead: K (LEP*6: 4; LEP*10: 5), Stroke: 25mm
Body Size: 10, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: M5, Option: Standard, Attachment: T (T-Interface), Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: RZ (R + Z)