SMC Corporation of America
Elite Part Number Search
Search Results "ASV110F-M3-04"

Part number Description Note ZS-40-A Lead wire with M8 connector Length: 3 m ZS-42-A Bracket With mounting screws for PFMC7501/7102 (M3 x 5, 2 pcs.)

As the indicator LED protrudes from the switch unit, mounting the switch bracket above the LED may cause damage to it. (4) Insert the auto switch mounting screw (M3) included in accessories from the mounting hole of the auto switch mounting band, inserting the through hole of the switch bracket.

) (LEMC/LEMH/LEMHT) T slots Model Bolt Max. tightening Effective length torque [Nm] [mm] LEMC25 LEMH25 M3 0.63 45 LEMC32 LEMH32 M5 3.0 68 LEMHT25 M4 1.5 67 LEMHT32 M6 5.2 810 -39- effective length of it to enter from the bottom. 5.

Screw Max. tightening torque (Nm) Maximum screw-in depth (mm) MHZ2-6 MHZJ2-6 M3 x 0.5 0.88 10 MHZA2-6 MHZAJ2-6 Model No. Screw Max. tightening torque (Nm) MHZ2-6 MHZJ2-6 M2.5x0.45 0.49 MHZA2-6 MHZAJ2-6 8 - Caution 1. Avoid twisting the gripper when mounting an attachment. Any damage to the gripper may cause malfunction and reduce the accuracy. 2. Avoid external force to fingers.

(M3 screw) 5 Output connector Output signal interface for valve manifold. 6 LED display LED display to indicate the status of the SI unit. 2 7 Mounting hole Mounting hole for connection to the valve manifold. Accessories Hexagon socket head cap screw 2 pcs. M3 x 30 screw for connection to the valve manifold.

) M2 M3 M1 M2 1.25 1.68 Slide 12 3 0.53 0.70 Ball bushing 3.34 4.25 Slide 16 7 1.53 2.11 Ball bushing 11.4 17.1 Slide l l 20 12 5.60 7.28 Ball bushing Note) For the purpose of calculating the moment, the length of the arm is the distance that is measured from the guide shaft center ( mark).

Dimensions L A LA Attached from top W C PA MM Note 1) M F HB HA Note 2) Attached from bottom: MD R Body B (mm) Note 1) Note 2) B C F HA HB L LA MM MD M PA R W A Model CY3B15 CY3B20 CY3B25 CY3B32 CY3B40 16 35 6.5 5.5 16.5 23 57 25 M4 x 0.7 M3 4 25 6 36 18 36 6.5 5.5 17 23.5 66 30 M4 x 0.7 M3 4 27 6 37 20 46 8.0 5.5 21 28.5 70 30 M5 x 0.8 M4 5 36 7 47 22.5 60 9.5 6.0 27.5 36 80 35 M6 x 1.0

CUX16-PS Proper tightening torque (Nm) (cylinder body) 10 16 20, 25 32 Hexagon socket head cap screw size (mm) M3 Bore size (mm) Rod seal 1 pc. CUX20-PS Gasket 1 pc. CUX25-PS 0.5410% Grease pack (10g) 1 pc. CUX32-PS M4 1.2310% Seals cannot be replaced for 10mm bore size. M5 2.5510% M6 4.0210% 2.

MVGQ 10 16 20, 25 32 0.54 10% M3 CUX32-PS Grease pack (10 g): 1 pc. 1.23 10% M4 It is impossible to replace seals in bore size 10 mm. CC 2.55 10% M5 4.02 10% M6 2. Grease pack When maintenance requires only grease, use the following part numbers to order. Grease pack GR-L-005 (5 g) GR-L-010 (10 g) GR-L-150 (150 g) RB Operating Precautions J Warning 1.

A Mounting screws (M3 x 8L) (accessory) Waterproof seal (accessory) Panel mount adapter Power supply/Output connection cable ZS-26-A Panel Front protective cover + Panel mount B Mounting screws (M3 x 8L) Front protective cover (accessory) Waterproof seal (accessory) Panel mount adapter Panel Options When only optional parts are required, order with the part numbers listed below.

Be aware that the output circuit is not active immediately after the power is connected. 3.1-12 PSE100 Dimensions A: Panel mount 56 l50 Gasket (Accessory) 7.4 l48 PRESSURE SWITCH 10 8 l 45 A Panel mount adaptor (Accessory) 55 11.4 Cover for display (Optional) 62 4 X 7.5 (= 30) 6.5 7.5 10-M3 2-M3 X 8L 30 View A Cutout dimensions for panel mount 65 or more 45 +0.6 0 +0.6 0 45 +0.6 0 N pieces

Mist generation pressure differential (MPa) IC EX: How to obtain the mist generating pressure differential if the flow rate obtaine in 1. above is 35 m3/min and the line pressure (inlet pressure P1) is 0.7 MPa: Extend horizontally from the point at which the flow rate is 35 m3/min to obtain the point that intersects with P1 = 0.7 MPa.

Mounting screw (M4) Terminal block cover M3 screw Gasket 6mm Electrical entry 2-G3/4 Step 3. How to replace the terminal block cover Securely tighten the screws to the torque shown in the table below, after confirming that the gasket is installed correctly.

Hexagon socket head cap screw (M3 x 0.5 x 16l) 2 pcs.

A Mounting screws (M3 x 8L) (Accessory) Waterproof seal (Accessory) Panel mount adapter Power supply/Output connection cable ZS-26-A Panel Front protective cover + Panel mount B Mounting screws (M3 x 8L) Front protective cover (Accessory) Waterproof seal (Accessory) Panel mount adapter Panel Option When only optional parts are required, order with the part numbers listed below.

Signal Cable Specications Power cable Terminal specications Cable specications Terminal block screw diameter Recommended crimped terminal 0.75 mm2 (AWG18) Shielded cable M3 Y-shape crimped terminal 1.25Y-3 Signal cable 15 Partially enlarged view A Series HRS100/150 Thermo-chiller Standard Type List of Function Operation Display Panel The basic operation of this unit is controlled through

(Tightening torque of M3 screw should be 0.5 to 0.7 Nm.) 5. Modification of the detecting position should be made in the condition of 3. Auto switch Auto switch mounting nut Auto Switch Mounting Bracket Part No.

Description Phillips Screw Tightening Torque 1 2 Gauge nut O-ring For IRV10(A): M3 For IRV20(A): M4 0.32 0.03 Nm 0.76 0.05 Nm Rc1/8 8 Vacuum Regulator Series IRV10/20 Pressure Gauge for Vacuum GZ43-K-01 IRV20 GZ33-K-01 IRV10 Part no.

Check the detecting position again and tighten the mounting screw to fix the auto switch definitely (the tightening torque of M3 screw should be about 50 to 70 N/cm). 5. Modification of the detecting position should be made following step #3. C76 C85 C95 Auto Switch Mounting Band Part No.

Attach the auto switch to the auto switch mounting bracket with the hexagon socket head cap screw (M3 x 14 L). The tightening torque for the M3 hexagon socket head cap screw is 0.5 to 0.8 Nm. 2. Fix the auto switch mounting nut and the auto switch mounting bracket temporarily by tightening the hexagon socket head cap screw (M2.5 x 5 L). 3.