Elite Part Number Search
Search Results "AC30C-N03-V-Z-D"

PFMC7--CNPN (1 output) + Analogue (4 to 20 mA) output type PFMC7--DMaximum applied voltage: 28 V Maximum load current: 80 mA Internal voltage drop: 1 V or less C: Analogue output: 1 to 5 V Output impedance: 1 k D: Analogue output: 4 to 20 mA Maximum load impedance: 600 Minimum load impedance: 50 NPN (1 output) + External input type PFMC7--GMaximum applied voltage: 28 V Maximum load current

Applicable cable O.D. 6 to 8 (D, DZ) P Pg9 J (DIN terminal: D, DZ) I (Grommet: G) F (Air operated) Pilot port 12 (P1) 2 x (Back side 10 (P2)) 4 x M 8 1 Manual override (Non-locking push type) P1 D S Q E 15 B A H (DIN terminal: D, DZ) G (Grommet: G) A R B C Main port 1 (A) (Back side 2 (B)) Port side: refer to table below Model Main port 1(A), 2(B) A B C D E F G H I J K L M N P Q R S VNB2V

DC(+) (OUT) 2 OUT2// 3 DC(-) 4 OUT1 (IN) M8 M8 IN OUT (UP) (SET) (DOWN) () OUT1OUT2 ON (1 ) (UP) ON/OFF (SET) (DOWN) ON/OFF -11No.PF-OMS0001CN-A F.S. ( 15 V F.S.=5[V]1[V]4[V] 1F.S.4[V]10.04[V] 15 V 15 V 420 mA ON OFF () (0100)() 90 () (0100) ()90ON(OFF) 0 1 atm()[nor] () 10 L/min 10 L ON OFF ON OFF 0 -12No.PF-OMS0001CN-A , , 2 5 10 L/min 5 ,51050 L ON-OFF () 1 L

Auto switch Auto Switch Specifications D-M9-5(With indicator light) Auto switch model D-M9P-5 Wiring 3-wire Output PNP type Applicable load IC circuit,Relay,PLC Power supply voltage 5 , 12 , 24 VDC (4.5 to 28 V) Current consumption 10 mA or less Load voltage 28 VDC or less Load current 40 mA or less Internal voltage drop 0.8 V or less at 10 mA (2 V or less at 40 mA) Current leakage 100 A

Auto switch Auto Switch Specifications D-M9N(With indicator light) Auto switch model D-M9N Electrical entry direction In-line Wiring 3-wire Output NPN type Applicable load IC circuit,Relay,PLC Power supply voltage DC51224V(4.5 to 28V) Current consumption 10 mA or less Load voltage Load current 40 mA or less Internal voltage drop 0.8 V or less at 10 mA (2 V or less at 40 mA) Current leakage

Refer to pages 17-6-3 to 17-6-10 for Safety Instructions and Solenoid Valve Precautions. 4 ' C ' C 1 (100 V) 2 (200 V) 3 (110 V) 4 (220 V) 7 (240 V) 8 (48 V) ) D G C D, T S S L, Z 3 ) E E 3 0 ( 2 17-3-69 2 The VX series will be revised shortly. Series VXH Construction/Dimensions Material C3771 Note No.

Ta 10 STa(S 10) = & I Ta (Nm) I: & 2 = & (rad/s2) 2 t 5.2 5.3 22 5.4 P A F 1 1 = (1) P A F 2 2 = (2) 2 1 D 4 A = (3) ) d D ( 4 A 2 2 2 = (4) F=[N] F=[N] = A=[mm] A=[mm] D=[mm] d=[mm] P=[MPa] 5.6 () 5.7 () 5.5 23 6. 6. 6. 6. ,, , ,, 6-1. 6.1 (m) DC AC 0.5 3 5 (L) (Z) (N) 3 (NPN) F7NV F79 3 (PNP) 5V,12V F7PV F7P IC F7BV J79 2 12V J79C 24V 3 (NPN) F7NWV F79W PLC 3 (PNP) 5V,

ZSE ISE PSE Z I SE3 2 Port Solenoid Valve Series VCA PS Precautions on Design Warning Z I SE1 2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 1.

IC circuit A96 A96V 5 V Yes 24 V Grommet A93V2 A93 A90 100 V Relay, PLC 2-wire 12 V A90V No IC circuit 100 V or less 1Although it is possible to mount water resistant type auto switches, note that the rotary actuator itself is not of water resistant construction. 21 m type lead wire is only applicable to D-A93.

Reed switch Solid state switch 5 V IC circuit Z76 Grommet Z73 A54 A59W Y59A Y7P J51 Y59B Y7NW Y7PW Y7BW Y7BA F59F 100 V 12 V Y es Relay, PLC 24 V 2-wire 100 V, 200 V Diagnostic indication (2-color indication) Grommet 3-wire (NPN) 3-wire (PNP) 24 V 5 V, 12 V IC circuit Grommet 12 V 100 V, 200 V 2-wire 3-wire (NPN) 3-wire (PNP) IC circuit Relay, PLC 5 V, 12 V Diagnostic indication

G E C T D DL S Z L 1, 2, 3, 4 (Only G)(Except G) 5, 6, 7 (Except DL)(Only T) (Only T) 17-4-13 2 Series VNB How to Order Seal material Body option Nil V Standard Vacuum pilot A B C NBR seals FKM seals EPR seals Thread type Bracket (valve size: 1/2/3/4.)

7. * The seal kit includes 2 cushion seals, 1 rod seal, 1 piston seal, and 2 tube gaskets. 1.7-27 Series MBlQ Basic/(B) G G Cushion valve W V Port 2-Rc(PT)P MM D E MB Effective thread 2 X 4-J lC lB MA A K F N N S + Stroke H ZZ + Stroke (mm) Stroke range Width across flats Bore (mm) Effective thread length A D Ee11 F N G P MA S MB V J W K H ZZ MM lC lB 32 40 50 63 80 100 22 30 35 35 40 40

D-H7BALD-H7NF D-G59WD-G5PWD-K59W D-G59FD-G5NT D-C73CD-C80C D-B54D-B64D-B59W 3. 4. () () (M4 1~1.2Nm (M3 0.6~1Nm 11 <> D-M9NM9PM9BM9NM9PVM9BV D-M9NWM9PWM9BWM9NWM9PWVM9BWV D-M9NAM9PAM9BAM9NAM9PAVM9BAV D-A90A93A96A90VA93VA96V 5. <> 6080 D-M9A(V) M3M3 0.60.7Nm (M2.5) (M2.5)0.050.1Nm 56mm 1)(M2.5) 2)M3 BMA3 A 12 4 1) (BMA2-A)(BJ5-1/) () 2) (BMA2-AS/)(BJ4-1/) D-M9A(V) () BBA3:D-B5,

Voltage output (1 to 5 V) 1 1 V 1.04 V 5 V Voltage output (0 to 10 V) 1, 2 0 V 0.1 V 10 V Current output 1 4 mA 4.16 mA 20 mA Models Minimum value of rated flow range Maximum value of rated flow range PFMC7501 5 L/min 500 L/min PFMC7102 10 L/min 1000 L/min PFMC7202 20 L/min 2000 L/min 1: Analogue output accuracy is within 3%F.S. 2: Set the current to the analogue output from the connected

IDX-OM-W095-A / Series IDFC60-23-C,L,R,T,V IDFC70-23-C,L,R,T,V IDFC80-23-C,L,R,T,V IDFC90-23-C,L,R,T,V URLhttp://www.smcworld.com/ English instruction manual can be downloaded from our URLhttp://www.smcworld.com/ SMC , ISO4414 *1) JIS B8370 *2) *1) ISO4414Pneumatic fluid power Recommendations for the application of equipment to transmission and control systems. *2) JIS B8370 URLhttp

2-wire 3-wire(NPN) IC circuit Diagnosis (2-color indicator) MHW MHW 5 V, 12 V Relay, PLC Grommet Yes 24 V 3-wire(PNP) 12 V 2-wire -X M9NAV 3-wire(NPN) Water resistant (2-color indicator) IC circuit 5 V, 12 V M9PAV M9PA 3-wire(PNP) MRHQ M9BAV M9BA 12 V 2-wire Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.

-wire(NPN) IC circuit Diagnosis (2-color indicator) 5 V, 12 V Relay, PLC Grommet Yes 24 V 3-wire(PNP) 12 V 2-wire M9NAV 3-wire(NPN) Water resistant (2-color indicator) IC circuit 5 V, 12 V M9PAV M9PA 3-wire(PNP) M9BAV M9BA 12 V 2-wire Auto switches marked with a symbol are produced upon receipt of order.

D-F9NL Auto Switch Weight Table Unit: oz Lead wire length Part no. 3m 0.5m D-F9N 36.5 6.5 D-F9B 30.7 5.7 D-F9NV 37 7.0 D-F9BV 31 6.0 Auto Switch Dimensions Auto Switch Internal Circuit (mm) / D-F9N D-F9B D-F9N (V) Split-pin set screw (M2.5 X 4l) Switch mounting screw + 2.7 Indicator light 2.8 Brown (Red) Switch main circuit Switch main circuit Output Black (White) 2 L 2.5 Blue (Black) Part

12 V 6 V 5 V 3 V 5 6 V S R Lead wire length 0.5 (2.9) m NPN output Analog output PNP output 27 26 67 Lead wire length 0.5 (2.9) m Lead wire length 0.5 (2.9) m Not required for Nil, vacuum adapter (GN) and vacuum pressure gauge (G).