Applicable cylinder bore size (mm) Model Metric size Inch size ASP 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS1001F 6, 10, 16, 20 ASN AS2001F 20, 25, 32 AS2051F 20, 25, 32, 40 AQ AS3001F 40, 50, 63 ASV AS4001F 63, 80, 100 AK Flow Rate and Effective Area ASS AS1001F AS2001F AS3001F AS2051F AS4001F Model JIS Symbol Metric size 6 6 8 10 6 8 3.2, 4, 6 4 10, 12 12 ASR Tubing O.D.
(W) [Current mA] DC 4.5/50 Hz, 4.2/60 Hz 100 VAC: 45/50 Hz, 42/60 Hz 200 VAC: 22.5/50 Hz, 21/60 Hz Note) Inrush Apparent power (VA) [Current mA] AC 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz 200 VAC: 17.5/50 Hz, 15/60 Hz Refer to pages 3-3-24 to 3-3-27 for manifold use.
PA06 1 100 35 100 (10) (7) (10) Electronic gear denominator *3.
, 15, 20 25, 32 40, 50, 63 CY1S, CY1L: 6 to 40 12, 16, 20 25, 32, 40 50, 63, 80 100 12, 16, 20 25, 32, 40 50, 63, 80 100 20, 25 32, 40 50, 63 32, 40 50, 63 80, 100 6, 10 16, 20 25, 32 10, 16 20 25, 32 12, 16 20, 25 32, 40 6, 10 15, 20 25, 32 6, 10 16 20, 25 32, 45 6, 10 16 20, 25, 32 40, 50 10, 15 25 12, 16 20, 25 Bore sizes (mm) 5 to 50mm/s 7 to 50 mm/s 5 to 50 mm/s 5 to 50mm/s Piston speed
-HL (10) IN-777-320TF-530F*-HL 150 150 average speed [mm/s] average speed [mm/s] Piston rod moving Piston rod moving 100 100 50 50 0 0 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 Speed adjustment rotary switch set value Speed adjustment rotary switch set value Measurement conditions Circuit Supply pressure: 0.55MPa Mount: Vertical downward mounting Load: No load Operating direction: Upward Air
Movement Speed Position Acceleration Deceleration Area 1 Area 2 In pos force Force speed force 2 2 mode mm/s mm mm/s mm/s mm mm mm Value mm/s 0 1 Absolute 100 100.00 1000 1000 50 40 10 100 0 0 5 2 Absolute 50 50.00 1000 1000 0 0 0 100 0 0 0.1 () (1)No.
16.5 16.5 16.5 16.5 16.5 16.5 24.1 18.1 18.1 25.1 25.1 31.1 50.1 50.1 MXQ16B 20.6 20.6 20.6 20.6 20.6 20.6 20.6 20.6 20.6 33 23 23 23 29 38 63 63 63 MXQ20B 32.2 21.2 21.2 21.2 21.2 21.2 21.2 21.2 21.2 30.9 31.9 31.9 31.9 44.9 44.9 46.9 69.9 69.9 Solid state auto switch: D-M9M9 A Stroke Stroke Model 10 20 30 40 50 75 100 125 150 10 20 30 40 50 75 100 125 150 MXQ6(A) 18 7.4 7.4 7.4 7.4 2
Refer to back page 50 for Safety Instructions and pages 6 to 8 for Air Preparation Equipment Precautions.
Applicable cylinder bore size (mm) Elbow type Universal type Port size Inch size Metric size Flat head screwdriver 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS121F-M5 AS131F-M5 6, 10, 16, 20 M5 x 0.8 AS221F-01 AS231F-01 20, 25, 32 R 1/8 AS221F-02 AS231F-02 20, 25, 32, 40 R 1/4 AS321F-02 AS331F-02 40, 50, 63 R 1/4 AS321F-03 AS331F-03 40, 50, 63 R 3/8 AS421F-04 AS431F-04 63, 80,
ISE79S Enclosure IP67 Withstand voltage 500 VAC for 1 minute between terminals and housing Environment Insulation resistance 1000 M or more between terminals and housing (with 50 VDC megger) Fluid temperature range -5 to 70 oC (No condensation or freezing) Ambient temperature range Operation: -5 to 50 oC, Storage: -10 to 60 oC (No condensation or freezing) Operating humidity range Operation
For a 10 orifice (VXS23/Port size 1/4), P 0.05 MPa The optimum size for a pressure differential of P 0.2 MPa and a flow of 50 L/min will be the VXS23 (10 orifice, port size 3/8). 500 400 VXS26 25 Cv = 12 300 VXS25 20 Cv = 9.2 200 VXS24 15 Cv = 5.3 Flow rate Q [L/min] 100 VXS23 Port size 3/8 10 Cv = 2.8 VXS23 Port size 1/4 10 Cv = 2.4 50 40 30 25 20 10 0.01 0.02 0.03 0.04 0.05 0.1 0.2 0.3
Series 10-V100 Rubber seal 3 port direct operated solenoid valve Specifications Air Fluid Ambient and fluid temperature (C) 10 to 50 (With no freezing. Refer to page 714.)
, SiC 10, Carbon 10, PP 10 3-phase 380 to 415VAC(50/60Hz) Allowable voltage range 10%(No continuous voltage fluctuation) Power supply 3-phase 460 to 480VAC(60Hz) Allowable voltage range +4%,-10%(Max. voltage less than 500V and no continuous voltage fluctuation) Rated current A 40 Electrical system Applicable earth leakage breaker Sensitivity current mA 30 Rated operating current 5 A 22 Rated
OUT1: Orange Digital filter*4 0, 10, 50, 100, 500, 1000, 5000 ms Enclosure IP40 Withstand voltage 1000 VAC for 1 minute between terminals and housing Insulation resistance 50 M or more (500 VDC measured via megohmmeter) between terminals and housing Environment Operating temperature range Operating: 5 to 50C, Stored: 10 to 60C (No condensation or freezing) Operating humidity range Operating
If an instantaneous flow of 10 L/min lasts for 5 minutes, the accumulated flow will be 10 x 5=50 L. Accumulated pulse output A type of output where a pulse is generated every time a predefined accumulated flow passes.It is possible to calculate the total accumulated flow by counting the pulses.
Table (10) shows the port size. Table (10) Port size Size Port size 50 to 100 Rc1/4 Perform followings before piping.
K 11 8 10 15 16 I 12 15 18 23 G 5.5 7.5 7.5 8 11 H 13 20 20.5 22 29 F 10 13 13 16 16 E 2 2 2 2 3 NN M10 x 1 M20 x 1.5 M26 x 1.5 M26 x 1.5 M32 x 2 D 16.6 21.6 26.4 33.6 41.6 MM M4 x 0.7 M4 x 0.7 M5 x 0.8 M6 x 1 M6 x 1 B 35 36 46 60 70 N 11 18 18.5 20 26 ZZ 103 132 137 156 182 NA 17 24 30 36 46 R 28 34 40 50 S 83 106 111 124 150 W 35 50 50 50 60 X 19 25 30 40 40 Model 12-CY3B15 12-CY3B20
(mm) ZX Pad diameter (mm) Lock ring 1 2 10 to 16 20 to 32 02 04 2 4 -X19 With lock ring Without lock ring (10 or larger) ZR 3 40, 50 06 6 08 8 ZM Material 10 10 N S NBR Silicon rubber 13 13 ZH 16 16 U Urethane rubber Pad style 20 20 ZU F Fluorine rubber 25 25 U C Flat Flat with ribs GN Conductive NBR (2 to 16) 32 32 GSConductive silicon rubber (2 to 16) 40 40 D Deep ZL 50 50 B Bellows 20
06, 07, 08, 09, 10 01, 23, 03, 04, 06, 07 01, 23, 03, 04, 06, 07 08, 09, 10, 11 08, 09, 10, 11 03, 04 400 200 06, 07 02 01, 23 300 50 03, 04 200 100 01, 23 100 0 0 0 5 0 10 5 0 10 5 0 10 Number of needle rotations Number of needle rotations Number of needle rotations Note) -U10/32 has the same specification as M5.