SMC Corporation of America
Elite Part Number Search
Search Results "ZSE20BF-V-P-N01-W"

10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (at NPN output)1 V or less2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)0.6 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 2.4 to 20 mA ?2.5% F.S.?

10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (at NPN output)1 V or less2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)1 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 4 to 20 mA ?2.5% F.S.?

10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (at NPN output)1 V or less2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)0.6 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 2.4 to 20 mA ?2.5% F.S.?

10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (at NPN output)1 V or less2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)1 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 4 to 20 mA ?2.5% F.S.?

10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (at NPN output)1 V or less2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)0.6 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 2.4 to 20 mA ?2.5% F.S.?

10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (at NPN output)1 V or less2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)1 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 4 to 20 mA ?2.5% F.S.?

10%, Ripple (p-p) 10% or less (with power supply polarity protection)45 mA or lessNPN or PNP open collector 2 outputs (Selectable)80 mA28 V (at NPN output)1 V or less2.5 ms (with anti-chattering function: 20, 100, 500, 1000, 2000 ms)Yes?0.2% F.S. ?1 digitVariable (0 or above) Note 1)Variable (0 or above) Note 1)0.6 to 5 V ?2.5% F.S.?1% F.S. or lessApprox. 1 k 2.4 to 20 mA ?2.5% F.S.?

(The SI unit type is provided for use in Japan.) + Voltage AC/DC 48 V 100 V Nil S None With seal w w Seal 50 mA 40 mA 20 mA Max. operating current and range Note 2) + Nil 6 Note1) Set pressure range 0.1 to 0.4 MPa 0.1 to 0.6 MPa a Semi-standard + Nil L Z 0.5 m 3 m 5 m Lead wire length q e b Series IS10 + Scale plate pressure unit MPa Both MPa and psi Nil P Note2) c CAT.ES60-19A

to 20 mA) output type PFM7--DMax. 28 V, 80 mA Internal voltage drop: 1 V or less C: Analogue output: 1 to 5 V Output impedance: 1 k D: Analogue output: 4 to 20 mA Max. load impedance: 600 Min. load impedance: 50 NPN (1 output) + External input type PFM7--GMax. 28 V, 80 mA Internal voltage drop: 1 V or less External input: No voltage input (reed switch or solid state), 30 ms or more -18No.PF-OMJ0006

D-F7BV D-F7BAL, D-J79W D.A72,D-A72H B i r w n l 8 t u w n (Black) D.F7PW D-E80A D-E73A (Black) o Reed swil.h Beed swltch o e Brue :Ei*" lblack) ked) D.A76H. D-E75A (+) E | 'FesisLort Black ;fi-+4--lrl" (-) o Series NCX2 6.14 10.14 Aub sr.

(also used for P610) Splined Shaft Fitting Assembly (short) (P) P305010-20 Connecting feedback shalt fo main spindle of actuator, Gauge Adaptor (w) NPT Run Tee fitting gauge installation (90") Gauge Adaptor (Y) Branch Tee litting gauge installation (90") G43-P2-N01 or KSlOB-SD2 For SlG, pressure range 0-30psi, 1/8 NPT A (+v) \

D-F7BV D-F7BAL, D-J79W D.A72,D-A72H B i r w n l 8 t u w n (Black) D.F7PW D-E80A D-E73A (Black) o Reed swil.h o e Beed swltch Brue :Ei*" lblack) ked) D.A76H. D-E75A (+) E | 'FesisLort Black ;fi-+4--lrl" (-) o Series NCX2 6.14 10.14 Aub sr.

(Example: If the Pressure switch with output impedance of 1k is connected to the A/D converter to detect the analogue output of 5 V, the detected voltage by the A/D converter becomes 5(V) 1(M)/(1(k) + 1(M)) 4.995(V), and there is an error of approximate 0.005 V.) Output impedance R The pressure range in which the Pressure switch satisfies the specifications.

(Example: If the Pressure switch with output impedance of 1k is connected to the A/D converter to detect the analog output of 5 V, the detected voltage by the A/D converter becomes 5(V) 1(M)/(1(k) + 1(M)) 4.995(V), and there is an error of approximate 0.005 V.) Output impedance R The pressure range in which the Pressure switch satisfies the specifications.

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8)

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -

Piping 01/N01 A B D ZS-24-A ZS-24-B ZS-24-D ZS-35-C ZS-35-D ZS-35-F ZS-35-G Bracket A Bracket B Bracket D E E Panel mount adapter Panel mount adapter + Front protective cover F W1/WF1/M5/C4/C6 Output specifications R T S V X Y NPN open collector 2 outputs + Analog voltage/Auto-shift switching PNP open collector 2 outputs + Analog voltage/Auto-shift switching NPN open collector 2 outputs +

Year Month T : 2015 o: January U : 2016 P: February V : 2017 Q: March W : 2018 R: April X : 2019 Z: December -7- 5. Precautions for handling Fluid Warning (1) The operating fluids must be compressed air.

Year Month T : 2015 o: January U : 2016 P: February V : 2017 Q: March W: 2018 R: April X : 2019 Z: December -7- 5. Precautions for handling Fluid Warning (1) The operating fluids must be compressed air.

Rated Vacuum Range: -101 to 0 kPa, Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)