SMC Corporation of America
Elite Part Number Search
Search Results "ZCDUKC20-50D-M9NLS"

Magnet: D (Built-in Magnet), VAC Side Tube/Rod End Shape: C (Cap Piping/Male Thread), Bore Size: 20mm, Port Thread: M5x0.8 (Bore 10, 16, 20, 25), Rc1/8 (Bore 32), Stroke: 50mm, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), VAC Side Tube/Rod End Shape: C (Cap Piping/Male Thread), Bore Size: 20mm, Port Thread: M5x0.8 (Bore 10, 16, 20, 25), Rc1/8 (Bore 32), Stroke: 50mm, Auto Switch: A96--Reed, DC Volt, LED, Horizontal, 0.5m, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), VAC Side Tube/Rod End Shape: C (Cap Piping/Male Thread), Bore Size: 20mm, Port Thread: M5x0.8 (Bore 10, 16, 20, 25), Rc1/8 (Bore 32), Stroke: 50mm, Auto Switch: A96--Reed, DC Volt, LED, Horizontal, 0.5m

Magnet: D (Built-in Magnet), VAC Side Tube/Rod End Shape: C (Cap Piping/Male Thread), Bore Size: 20mm, Port Thread: M5x0.8 (Bore 10, 16, 20, 25), Rc1/8 (Bore 32), Stroke: 50mm, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal

Magnet: D (Built-in Magnet), VAC Side Tube/Rod End Shape: C (Cap Piping/Male Thread), Bore Size: 20mm, Port Thread: M5x0.8 (Bore 10, 16, 20, 25), Rc1/8 (Bore 32), Stroke: 50mm, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), VAC Side Tube/Rod End Shape: C (Cap Piping/Male Thread), Bore Size: 20mm, Port Thread: M5x0.8 (Bore 10, 16, 20, 25), Rc1/8 (Bore 32), Stroke: 50mm, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)

Magnet: D (Built-in Magnet), VAC Side Tube/Rod End Shape: C (Cap Piping/Male Thread), Bore Size: 20mm, Port Thread: M5x0.8 (Bore 10, 16, 20, 25), Rc1/8 (Bore 32), Stroke: 50mm, Auto Switch: M9NW--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), VAC Side Tube/Rod End Shape: C (Cap Piping/Male Thread), Bore Size: 20mm, Port Thread: M5x0.8 (Bore 10, 16, 20, 25), Rc1/8 (Bore 32), Stroke: 50mm, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)

Magnet: D (Built-in Magnet), VAC Side Tube/Rod End Shape: C (Cap Piping/Male Thread), Bore Size: 20mm, Port Thread: M5x0.8 (Bore 10, 16, 20, 25), Rc1/8 (Bore 32), Stroke: 50mm, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: Z (5m)

Magnet: D (Built-in Magnet), VAC Side Tube/Rod End Shape: C (Cap Piping/Male Thread), Bore Size: 20mm, Port Thread: M5x0.8 (Bore 10, 16, 20, 25), Rc1/8 (Bore 32), Stroke: 50mm, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector)

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.11 to 0.7, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.11 to 0.7, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.11 to 0.7, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.11 to 0.7, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.11 to 0.7, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard / With rod detent function, Environment, Applications: Standard / Vacuum, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.11 to 0.7, Specification: Built-in magnet, Port thread

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

MLGC 40 50 63 80 100 MNB 40D-UA MNB 50D-UA CNG P 0.3 MPa MNB 63D-UA Piston rod assembly MNB 80D-UA MNB MNB100D-UA CNA 2. How to replace lock unit 1) Loosen the tie-rod nuts (4 pcs.) on the cylinder head cover side by using a hexagon wrench. For the applicable hexagon wrench, refer to the table below.

Bore size (mm) 40 50 63 80 100 Lock unit order number MNB 40D-UA MNB 50D-UA P0.3MPa Piston rod assembly P0.3MPa MNB 63D-UA MNB 80D-UA MNB100D-UA 2. Replacement of lock units. 1) Loosen the tie-rod nuts (4pcs.) on the cylinder head cover using a hexagon wrench. Refer to the table below for the applicable hexagon wrench.

.: CQSB25-47D CQSB25-50D with 3 mm width spacer inside. B dimension is 72.5 mm. Example Refer to pages 595 to 597 for cylinders with auto switches. Minimum auto switch mounting stroke Proper auto switch mounting position (detection at stroke end) and mounting height Operating range Switch mounting bracket/Part no. 552