SMC Corporation of America
Elite Part Number Search
Search Results "ZA1051-J15G-P1-22"

P1 = 0.7MPa 0.08 0.08 P1 = 0.7MPa P1 = 0.5MPa P1 = 0.3MPa Pressure drop MPa Pressure drop MPa P1 = 0.1MPa P1 = 0.5MPa 0.06 0.06 P1 = 0.1MPa P1 = 0.3MPa 0.04 0.04 Maintenance Warning 1.

Analog Output Characteristics Hysteresia mode when the values of P1 and P2 are equal or when P1>P2 but within 3 digits, the hysteresis will be automatically set to 3 digits tor the set value ot P1. Window comparator mods The hysteresis is automatically set to 3 digits, so separate P1 trom P2 by 7 digils or more when programming.

21.5 31 17.5 16.1 18 41 62.4 24.3 38.1 66.2 26.2 40 16.5 3.5 16.8 18.7 11 1.2 41 56 17 40 60 6 8 VHK-B1A 44.5 11.5 27 22 16.5 26 9.7 7.2 3 8 22 46 74.8 30.5 44.3 77.3 31.5 45.8 21.5 4 20.8 21.8 14 3.2 51 68 19 64 71 22 10 12 VHK-B2A 49 17 1 30 25 21.5 31 17.5 16.1 22 46 78.2 30.5 47.7 80.2 31.5 48.7 21.5 4 20.8 21.8 14 3.2 72 70 22 70 72 10 12 VHK-B2A 49 17 1 30 25 21.5 31 17.5 16.1 1 2

Type) Dimensions: Air Operated Type PA3000 115 68 85 VC VDW 105 4-7 7.5 VQ FLUID OUT Rc 3/8 5.5 VX2 AIR SUP(P1) Rc 1/4 VX Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com FLUID OUT PROCESS PUMP VX3 P1 2 VXA 90 74.5 FLUID I N VN P2 44.5 3 32 Rc 1/4 AIR SUP(P2) LVC

18 ANA1-03 3/8 35 22 84 25 21 ANA1-04 1/2 60 36 98 30 24 ANA1-06 3/4 90 110 111 46 36 ANA1-10 1 160 180 132 50 41 ANA1-12 11/4 280 544 200 74 60 ANA1-14 11/2 450 612 230 74 60 ANA1-20 2 610 873 271 86 70 ANB1-01 1/8 15 10 51 22 ANB1-02 1/4 35 22 81 25 18 ANB1-03 3/8 60 35 93 30 21 ANB1-04 1/2 90 94 107 46 24 ANB1-06 3/4 160 175 133 50 41 ANB1-10 1 280 462 190 74 41 ANB1-12 11/4 450 612 230

How to Find the Flow Rate (at air temperature of 20C) Subsonic flow when P1 + 0.1013 < 1.89 (P2 + 0.1013) Q = 226S P(P2 + 0.1013) Sonic flow when P1 +0.1013 1.89 (P2 + 0.1013) Q = 113S (P1 + 0.1013) Q : Air flow rate [l/min (ANR)] S : Effective area (mm) P : Pressure drop (P1 P2) [MPa] P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] Correction for different air temperatures Multiply

Pilot port P1 and P2 piping Please arrange P1 and P2 piping as follows according to the model.

For saturated steam Viewing the graph [664] (183) Upstream pressure of valve P1 = 1.0MPa 1.0 The sonic range pressure to generate a flow rate of 25kg/h for orifice 3 (VCS21) is P1 approx. 0.68MPa for orifice 4 (VCS21) is P1 approx. 0.40MPa for orifice 5 (VCS21) is P1 approx. 0.29MPa The holding heat differs somewhat depending on the pressure P1, but at 25kg/h it is approximately 16000kcal

L1 L2 L2 Main circuit power supply L3 L3 Regenerative converter N P1 P2 N DC reactor Connect between P1 and P2. (Connected at time of shipping.) P1 Control Circuit Power Supply Connector: CNP2 Accessory P2 Terminal name Function Function details P P C D L11 L21 Connect between P and D. (Connected at time of shipping.)

Exhaust port 77.8 59.3 Silencer (For EXH port) This silencer is to be inserted into the EXH port (Onetouch fittings) of the common exhaust. 22 Dimensions Applicable fittings size d 20 Noise reduction (dB) Effective area (mm2 ) Series Model A L D VQ2000 8 AN200-KM8 59.3 77.8 22 30 Port plug VVQ1000-58A The plug is used to block the cylinder port when usinga 4 port valve as a 3 port valve.

N N P1 P2 Connect between P1 and P2. (Connected at time of shipping.) P1 Control Circuit Power Supply Connector: CNP2 Accessory P2 Terminal name Function Details P P C D Connect between P and D. (Connected at time of shipping.) If regeneration option is required for Model Selection, connect to this Regeneration C option terminal. D Connect the control circuit power supply.

Pressure P1 (Index 64) Table 3-9. Pressure P1 Sub Size Acc ess Default (dec) Content Description index [byte] 1 2 R/W 0x0258 Vacuum confirmation threshold (P1) of CH0 Set vacuum confirmation threshold (P1) for each CH. Refer to Section 5.

approx. 0.77MPa, for orifice 3 (VDW30) is P1 approx. 0.45MPa, for orifice 4 (VDW30) is P1 approx. 0.24MPa.

v=l t P"p1 + 147 Where V = capacity of rceiver Q = compressor outpul (clm) Pa = atmosphric plsssurc P1 = compressor outsul pressure V = (600'14.7y(10O+14.7) =77lf as a minimum number, a prudent suggestion might begin with 120 ft".

Port P2 Port P1 P2 P2 P1 P2 Port P1 Pressure is applied Operating direction P1 Pressure is applied Operating direction P2 Pressure is applied P2 Pressure is applied 1486 Magnetically Coupled Rodless Cylinder 3-Options available for stroke adjustment Bumper bolt (resin tipped) Bumper bolt (Same on the opposite side) Shock absorber + Adjustment bolt (metal ended) Adjustment bolt (Same on

Working Principle: Air Operated Type (PAF3413, 5413) Air supply port (AIR SUP) 5 port solenoid valve External solenoid valve P1 P2 Discharge port (FLUID OUT) Drive unit Pump chamber B Pump chamber A Check valve Shaft Suction port (FLUID IN) Drive chamber A Drive chamber B Diaphragm B Diaphragm A 1. When air is supplied to P1 port, it enters drive chamber A. 2.

L Dimension 21 273 22 285.5 23 298 24 310.5 25 323 26 335.5 27 348 28 360.5 29 373 30 385.5 ZK2 SE2 A 1 No.

N N P1 P2 DC reactor Connect between P1 and P2. (Connected at time of shipping.) P1 Control Circuit Power Supply Connector: CNP2 Accessory P2 Terminal name Function Function details P P C D Connect between P and D. (Connected at time of shipping.) If regeneration option is required for Model Selection, connect to this terminal.

(mm) D1 Note) A Weight (g) 6-applicable tubing D2 P2 L2 L3 M P1 L1 Model L1 1 8 1 4 3 8 1 8 1 4 3 8 1 8 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 KQ2ZT04-01S 18.5 54.5 50.5 25 31 44 27 33 46 56 54 62 P2 14 KQ2ZT04-02S 10.4 13.4 21 16 13.4 10.4 4 21.5 57.5 51.5 KQ2ZT04-03S 17 23.5 59.5 53.5 L2 P1 P1 D1 KQ2ZT06-01S 18.5 54.5 50.5 14 6 KQ2ZT06-02S 21.5 57.5 51.5 12.8 13.4 22 17 13.4 12.8 KQ2ZT06-03S

Solenoid valve 22 XL Series Specific Product Precautions 3 Be sure to read this before handling the products. Refer to the back cover for safety instructions.