#Actuator cable Pages 42, 56 Standard cable Controller type Robotic cable LE-CP-;-S LE-CP-;-S LE-CP-; LE-CA-; LE-CP-; LECP6 (Step data input type) LECA6 (Step data input type) LECP1 (Programless type) The mark: Can be included in the How to Order for the actuator.
Actuator cable Pages 59, 73 Standard cable Controller type Robotic cable LE-CP--S LE-CP--S LE-CPLE-CALE-CPLECP6 (Step data input type) LECA6 (Step data input type) LECP1 (Programless type) The mark: Can be included in the How to Order for the actuator.
ALARM and ESTOP are expressed as negative-logic circuit. 23 Series LECP6 Series LECA6 Options [Actuator cable for step motor (Servo/24 VDC)] Controller side LE-CP/Cable length: 1.5 m, 3 m, 5 m 1 3 5 LE CP 1 (14.2) (Terminal no.)
.: LEC-W1 P Actuator cable Pages 19, 29 Robotic cable Standard cable Controller type LECP6 (Step data input type) LECP1 (Programless type) LE-CP-m LE-CP-m LE-CP-m-S LE-CP-m-S Communication cable P (3 m) Motor cable (Fixed) P P USB cable P Electric actuator (A-mini B type) Electric actuator/ Guide rod slider Page 4 PC Or P Teaching box (Option) Page 22 Part no.: LEC-T1-3JGm with 3 m cable
.: LEC-W1 Standard cable Robotic cable Controller type LE-CP-m-S LE-CP-m LE-CA-m LE-CP-m LECP6 (Step data input type) LECA6 (Step data input type) LECP1 (Programless type) LE-CP-m-S Communication cableP (3 m) Conversion unitP Motor cable (Fixed)P PUSB cable PElectric actuator (A-mini B type) Rod Type Guide Rod Type Page 25 Page 5 Series LEY Series LEYG PC Or PTeaching box (Option) Page 49
Station 6 Station 12 Station 18 Station 24
Actuator cable Pages 21, 33 Standard cable Controller type Robotic cable LECP6 (Step data input type) LECP1 (Programless type) LE-CPLE-CPLE-CP--S LE-CP--S The mark: Can be included in the How to Order for the actuator.
Actuator cable Pages 61, 73 Standard cable Controller type Robotic cable LECP6 (Step data input type) LECP1 (Programless type) LE-CPLE-CPLE-CP--S LE-CP--S The mark: Can be included in the How to Order for the actuator.
Ethernet cable (With shield, Category 5 or higher) VController/JXC92 To P1 or P2 To ENC VActuator cable p. 17 Robotic cable Standard cable LE-CP-LE-CP---S To MOT To CI To USB VControl power supply connector (Accessory) p. 12
CN1P.17 4.2 CN2CN3: LE-CP-LE-CP---S CN3 CN2 4.3 CN4I/O PLC I/O CN4 PLC *6.4 I/O P.23 *6.3 P.21 16 No.JXC-OMU0004-A 5.
.: LEC-W1 PActuator cable Pages 31, 40 Robotic cable Standard cable Controller type LECP6 (Step data input type) LECP1 (Programless type) LE-CP-m LE-CP-m LE-CP-m-S LE-CP-m-S Communication cable P (3 m) Motor cable (Fixed) P PUSB cable P Electric actuator (A-mini B type) Series LEPY Page 5 Series LEPS PC Page 15 Or Page 33 PTeaching box (Option) Part no.: LEC-T1-3JGm with 3 m cable Features
Dimensions C 40 52 63 D Note) A B 29 33 41 Model C B VQZ1000 VQZ2000 VQZ3000 35 43 52 67 81 93 A Note) Grommet Port plug VVQZ1000-CP (for VQZ1000) VVQZ2000-CP (for VQZ2000) VVQZ3000-CP (for VQZ3000) Used to block a cylinder port when changing 5 port valves into 3 port valves, etc. 959 Series VQZ1000/2000/3000 Manifold Options Name plate [-N] (Applicable to VQZ2000/3000) VVQZ2000-N5VVQZ3000
Measurement is possible as long as the fluid does not corrode the wetted parts, and viscosity is 3mPas (3 cP) or less.
Net 6 CP-L006A Foot (1 pc.) 10 CP-L010A 16 CP-L016A *Material of foot is iron. *Please consult separately about for 4. Flange Bore size (mm) Kit no. Net 6 CP-F006A Flange (1 pc.) 10 CP-F010A 16 CP-F016A *Material of flange is iron. *Please consult separately about for 4. Trunnion Bore size (mm) Kit no. Net 6 CP-T006A Trunnion (1 pc.)
Option Bore size (mm) Description 6 Bore size (mm) Bracket 6 Symbol Specifications 10 16 10 16 XA Change of rod end style XB6 Heat resistant cylinder (150C) Auto switch D-A9(V), D-M9(V), D-M9W(V) Flange CP-F006A CP-F010A CP-F016A XB7 Cold resistant cylinder Foot Single knuckle joint CP-L006A CP-L010A CP-L016A I-P006A I-P010A I-P016A XC22 Fluororubber seals Trunnion (with pin) CP-T006A CP-T010A
Option Bore size (mm) Description 6 Bore size (mm) Bracket 6 Symbol Specifications 10 16 10 16 XA Change of rod end style XB6 Heat resistant cylinder (150C) Flange CP-F006A CP-F010A CP-F016A Auto switch D-A9(V), D-M9(V), D-M9W(V) XB7 Cold resistant cylinder Foot CP-L006A CP-L010A CP-L016A Single knuckle joint I-P006A I-P010A I-P016A XC22 Fluororubber seals Trunnion (with pin) CP-T006A CP-T010A
Gsftrc ArrC'r-rrrns6'r CP seies Cylinder Positioner Assembly Bore Sizes: s50mm, o63mm, s80mm, g100mm lnfinite Control tromZero to FullStroke 3-15 psig Signal Pressure Built-in Feed Back Non-lubed Operation is Standard SERIES CP CYLINDER POSITIONING ASSEMBLY SPECIFICATIONS SPECIFICATIONS CHARACIER|tiNCS Supply Prsgsure 40-100 PSlc (3.0-7.0 KsTcmr) Signal Presure 3-15 PSlc (0.2-l Kq/cm,)
Clevis style 3 7 12 Theoretical Output (N) Bore size (mm) Mounting 15 6 10 80 Trunnion (With pin) 18 32 Operating pressure (MPa) CP-F015 CP-F006 CP-F010 Flange style Bore size (mm) Operating direction 0.3 0.5 0.7 CP-L015 CP-L006 CP-L010 Foot style 6.36 14.8 IN 10.6 CP-T015 CP-T006 CP-T010 Trunnion style (With pin) 6 8.48 19.8 OUT 14.1 Auto Switch Mounting Bracket Part No. 17.7 41.2 IN 29.4
Clevis style 3 7 12 Theoretical Output (N) Bore size (mm) Mounting 15 6 10 80 Trunnion (With pin) 18 32 Operating pressure (MPa) CP-F015 CP-F006 CP-F010 Flange style Operating direction Bore size (mm) 0.3 0.5 0.7 CP-L015 CP-L006 CP-L010 Foot style 6.36 14.8 IN 10.6 CP-T015 CP-T006 CP-T010 Trunnion style (With pin) 6 8.48 19.8 OUT 14.1 Auto Switch Mounting Bracket Part No. 17.7 41.2 IN 29.4