Stop Ensure that the circulating fluid flow is 5l/min.or more. Check the heat load are within the specified range. AL06 High circulating fluid discharge pressure Stop Check the user's piping for bends, squash and foreign matters. AL07 Abnormal pump operation Stop Restart and check the pump is operating.
Fluid: Air/inert gas , Operating pressure range: 0MPa/10Torr (Vacuum) - 0.7MPa (7.1kgf/cm 2 ) , Effective area (Cv factor): Standard type 0.9mm 2 (0.05); high flow type 1.5mm 2 (0.08) , Coil rated voltage: 12, 24VDC , Response time: ON: 4ms; OFF: 2ms , Ambient/fluid temp: -10 to 50C, VQD1151 OTHER SIZE RATING, VALVE, VQD1151 VALVE, SOL 4/5-PORT, 15, VQD1151 OTHER SIZE RATING, 0.06827
Fluid: Air/inert gas , Operating pressure range: 0MPa/10Torr (Vacuum) - 0.7MPa (7.1kgf/cm 2 ) , Effective area (Cv factor): Standard type 0.9mm 2 (0.05); high flow type 1.5mm 2 (0.08) , Coil rated voltage: 12, 24VDC , Response time: ON: 4ms; OFF: 2ms , Ambient/fluid temp: -10 to 50C, VQD1151 NO SIZE RATING, VALVE, VQD1151 VALVE, SOL 4/5-PORT, 25, VQD1151 NO SIZE RATING, 0.15156 lb
Fluid: Air/inert gas , Operating pressure range: 0MPa/10Torr (Vacuum) - 0.7MPa (7.1kgf/cm 2 ) , Effective area (Cv factor): Standard type 0.9mm 2 (0.05); high flow type 1.5mm 2 (0.08) , Coil rated voltage: 12, 24VDC , Response time: ON: 4ms; OFF: 2ms , Ambient/fluid temp: -10 to 50C, VQD1151 OTHER SIZE RATING, VALVE, VQD1151 VALVE, SOL 4/5-PORT, 1D, VQD1151 OTHER SIZE RATING, 0.16534
Please contact us for the latest version.sales@ocaire.com, VQD1151 NO SIZE RATING, VALVE, VQD1151 VALVE, SOL 4/5-PORT, 2D, VQD1151 NO SIZE RATING, 0.22046 lb
Fluid: Air/inert gas , Operating pressure range: 0MPa/10Torr (Vacuum) - 0.7MPa (7.1kgf/cm 2 ) , Effective area (Cv factor): Standard type 0.9mm 2 (0.05); high flow type 1.5mm 2 (0.08) , Coil rated voltage: 12, 24VDC , Response time: ON: 4ms; OFF: 2ms , Ambient/fluid temp: -10 to 50C, VQD1151 NO SIZE RATING, VALVE, VQD1151 VALVE, SOL 4/5-PORT, 2D, VQD1151 NO SIZE RATING, 0.11098 lb
Fluid: Air/inert gas , Operating pressure range: 0MPa/10Torr (Vacuum) - 0.7MPa (7.1kgf/cm 2 ) , Effective area (Cv factor): Standard type 0.9mm 2 (0.05); high flow type 1.5mm 2 (0.08) , Coil rated voltage: 12, 24VDC , Response time: ON: 4ms; OFF: 2ms , Ambient/fluid temp: -10 to 50C, VQD1151 NO SIZE RATING, VALVE, VQD1151 VALVE, SOL 4/5-PORT, 2D, VQD1151 NO SIZE RATING, 0.22046 lb
Please contact us for the latest version.sales@ocaire.com, VQD1151 NO SIZE RATING, VALVE, VQD1151 VALVE, SOL 4/5-PORT, 2D, VQD1151 NO SIZE RATING, 0.11023 lb
Actuation: 1 (Single Type), Body: 5 (Base Mounted), Option: Standard, Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Connector, w/o Connector; with Light/Surge Voltage Suppressor), Port Size: M5
Actuation: 1 (Single Type), Body: 5 (Base Mounted), Option: Standard, Voltage: 5 (24 VDC), Electrical Entry: MO (M Plug Connector, w/o Connector; with Light/Surge Voltage Suppressor), Port Size: M5
Actuation: 1 (Single Type), Body: 5 (Base Mounted), Option: Standard, Voltage: 6 (12 VDC), Electrical Entry: L (L Plug Connector, w/Lead Wire; with Light/Surge Voltage Suppressor), Port Size: M5
Actuation: 1 (Single Type), Body: 5 (Base Mounted), Option: Standard, Voltage: 6 (12 VDC), Electrical Entry: MO (M Plug Connector, w/o Connector; with Light/Surge Voltage Suppressor), Port Size: M5
Actuation: 1 (Single Type), Body: 5 (Base Mounted), Option: Standard, Voltage: 6 (12 VDC), Electrical Entry: M (M Plug Connector, w/Lead Wire; with Light/Surge Voltage Suppressor), Port Size: M5
Actuation: 1 (Single Type), Body: 5 (Base Mounted), Option: Standard, Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Connector, w/Lead Wire; with Light/Surge Voltage Suppressor), Port Size: M5
Actuation: 1 (Single Type), Body: 5 (Base Mounted), Option: Standard, Voltage: 6 (12 VDC), Electrical Entry: LO (L Plug Connector, w/o Connector; with Light/Surge Voltage Suppressor), Port Size: M5
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard, Valve Type: 4-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Open, Pipe Port Type: M, Port Size: M5, Pressure Rating(MPa): 0~0.7, Driving Type: Linear Motion Poppet, Pilot Air Supply: Internal
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard, Valve Type: 4-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Open, Pipe Port Type: M, Port Size: M5, Pressure Rating(MPa): 0~0.7, Driving Type: Linear Motion Poppet, Pilot Air Supply: Internal
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard, Valve Type: 4-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Open, Pipe Port Type: M, Port Size: M5, Pressure Rating(MPa): 0~0.7, Driving Type: Linear Motion Poppet, Pilot Air Supply: Internal
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC12V, Specification: Standard, Valve Type: 4-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Open, Pipe Port Type: M, Port Size: M5, Pressure Rating(MPa): 0~0.7, Driving Type: Linear Motion Poppet, Pilot Air Supply: Internal
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC12V, Specification: Standard, Valve Type: 4-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Open, Pipe Port Type: M, Port Size: M5, Pressure Rating(MPa): 0~0.7, Driving Type: Linear Motion Poppet, Pilot Air Supply: Internal