This is a legacy product, and replaced byVT307-5DZ1-01-F, VT3 BASE MT 1/4, VALVE, VT3/VO3 SOL VALVE 3-PORT, PA, VT3 BASE MT 1/4, 0.58907 lb
This is a legacy product, and replaced byVT307Y-5DZ1-01-F, VT3 BASE MT 1/4, VALVE, VT3/VO3 SOL VALVE 3-PORT, PA, VT3 BASE MT 1/4, 0.4924 lb
This is a legacy product, and replaced byVP744-5DZ1-04A
Assembly example qResidual pressure relief 3 port solenoid valve VP517Y-5DZ1 1 pc. wAir combination AC30C-03DG 1 pc. eSpacer with bracket Y300T-A 1 pc. tPiping adapter *1 *2 rSpacer Y300-A 1 pc. tPiping adapter E300-03-A 1 pc. q Residual pressure relief 3 port solenoid valve Applicable Combinations/Attachment Part Nos. 3 port solenoid valve Applicable air combination Spacer Spacer with bracket
This is a legacy product, and replaced byVP742R-5DZ1-04A
This is a legacy product, and replaced byVP742R-5DZ1-04A
Assembly example qResidual pressure relief 3 port solenoid valve VP517Y-5DZ1 1 pc. wAir combination AC30C-03DG 1 pc. eSpacer with bracket Y300T-A1 pc. tPiping adapter *1 *2 rSpacer Y300-A1 pc. tPiping adapter E300-03-A1 pc. q Residual pressure relief 3 port solenoid valve Applicable Combinations/Attachment Part Nos.
Mr=W (L3 + C) = 10 (.05 + 0.014) =0.64 [N m] W Mr 2 =Mr/Mr max. =0.64/12 =0.053 Mr: Mr max. value is from
MSM011P1A MSM012P1A 100 100/115 200/230 100/115 200/230 100/115 200/230 MSD011P1E MSD013P1E MR-C10A1 MR-C10A SGDE-01BP SGDE-01AP Matsushita Electric Industrial Co., Ltd. For a non-standard motor specification, when the motor is mounted before shipping, the driver is included but the cable that connects the motor and driver is optional. Refer to page 178 for part numbers.
X12 100/110VAC Tamagawa Seiki Co., Ltd. 111.5 80.5 X13 200/220VAC MSD3A1P1E MSD3A1P1E MSD3A3P1E MSD3A3P1E MR-C10A1 MR-C10A1 MR-C10A MR-C10A SGDE-A3BP SGDE-A3BP SGDE-A3AP SGDE-A3AP X15 100/115VAC Matsushita Electric Industrial Co., Ltd. 123 91 X16 200VAC 30W X18 100/115VAC Mitsubishi Electric Corporation 111.5 87.5 X19 200/230VAC X21 100/115VAC Yaskawa Electric Corporation 123 91.5 X22 200
Static moment Mr = W x 9.8 (L3 + C) Examine Mr. (Mp, My values do not apply to this example.) W = 1 x 9.8 (0.05 + 0.014) = 0.63 [Nm] Mr 2 = Mr/Mrmax Mrmax value is from Graph (3) at Va = 300 mm/s. = 0.63/12 L3 + C = 0.053 Mey = 1/3We x 9.8 (L2 + B) V = 1.4Va We = WV = 4/10011.4300 = 168 [kg] Mey = 1/3 x 16.8 x 9.8 (0.05 + 0.037) = 4.8 [Nm] 3 = Mey/Meymax = 4.8/14.3 = 0.34 3.
B L2 1 = W/Wmax = 1/7 = 0.14 L3 C Static moment Mr = W x 9.8 (L3 + C) W Examine Mr.
X12 100/110VAC Tamagawa Seiki Co., Ltd. 111.5 80.5 X13 200/220VAC MSD3A1P1E MSD3A1P1E MSD3A3P1E MSD3A3P1E MR-C10A1 MR-C10A1 MR-C10A MR-C10A SGDE-A3BP SGDE-A3BP SGDE-A3AP SGDE-A3AP X15 100/115VAC Matsushita Electric Industrial Co., Ltd. 123 91 X16 200VAC 30W X18 100/115VAC Mitsubishi Electric Corporation 111.5 87.5 X19 200/230VAC X21 100/115VAC Yaskawa Electric Corporation 91.5 123 X22 200
1/8 8 1/8 6 1 3/4 1 1/4-12 2 2.375 3/8 1 1/8 3 1/16 5 3/4 3 1/8 8 3/8 6 2 1 1/2-12 2 1/4 2.625 3/8 1 1/4 3 3/16 5 3/4 3 1/8 8 1/2 HEAVY DUTY Bore CB CD CW E EE(NPT) F 1 1/2 3/4 1/2 1/2 2 3/8 3/8 2 3/4 1/2 1/2 2 1/2 3/8 3/8 2 1/2 3/4 1/2 1/2 3 3/8 3/8 3 1/4 1 1/4 3/4 5/8 3 3/4 1/2 5/8 4 1 1/4 3/4 5/8 4 1/2 1/2 5/8 5 1 1/4 3/4 5/8 5 1/2 1/2 5/8 6 1 1/2 1 3/4 6 1/2 3/4 3/4 BORE G J K L LR MR
Lead 3: LEY25C 60 Lead 6: LEY25B LEF Regeneration Option Models 50 Work load [kg] Size Model LEY25 LEC-MR-RB-032 LEY32 LEC-MR-RB-032 LEY63 Lead 12: LEY25A LEJ 40 Area where the regeneration option is required.
1/8 8 1/8 6 1 3/4 1 1/4-12 2 2.375 3/8 1 1/8 3 1/16 5 3/4 3 1/8 8 3/8 6 2 1 1/2-12 2 1/4 2.625 3/8 1 1/4 3 3/16 5 3/4 3 1/8 8 1/2 HEAVY DUTY Bore CB CD CW E EE(NPT) F 1 1/2 3/4 1/2 1/2 2 3/8 3/8 2 3/4 1/2 1/2 2 1/2 3/8 3/8 2 1/2 3/4 1/2 1/2 3 3/8 3/8 3 1/4 1 1/4 3/4 5/8 3 3/4 1/2 5/8 4 1 1/4 3/4 5/8 4 1/2 1/2 5/8 5 1 1/4 3/4 5/8 5 1/2 1/2 5/8 6 1 1/2 1 3/4 6 1/2 3/4 3/4 BORE G J K L LR MR
Symbol Signal description Signal description Driver model MR-C10A MR-C20A MR-C10A1 MR-C20A1 Symbol Digital output power supply Failure Positioning complete Z phase pulse 1 2 3 4 5 7 8 9 10 11 12 13 14 15 16 17 19 20 V+ ALM PF OP SG NP NG PP PG Shield SD SG CR LSN LSP V5 SON OPC V24 Interface power supply common Clear Reverse stroke end Normal stroke end Interface power supply Servo ON Open
Mr: Roll moment H H, L: Distance to the point at which the load is applied (mm) Model Static allowable moment Allowable vertical load Fv [N] Pitch moment: Mp [Nm] Yaw moment: My [Nm] Roll moment: Mr [Nm] LEHF10K2LEHF20K2LEHF32K2LEHF40K20.53 0.26 0.26 58 1.4 0.68 0.68 98 2.8 1.4 1.4 176 4 2 2 294 Note) Values for load in the table indicate static values.
Output Black lead wire 50 MSM5AZP1A MSD5A3P1E 200/230 MR-C10A1 100/115 Mitsubishi Electric Corporation HC-PQ053 50 MR-C10A 200/230 SGDE-A5BP SGME-A5BF12 100/115 Yaskawa Electric Corporation Blue lead wire SGME-A5AF12 50 SGDE-A5AP 200/230 H S For motor mounting dimensions, refer to the dimensions for series LJ1 10 on page 143 as a reference for mounting and design.
Signal description Symbol Digital output power supply Failure Positioning complete Z phase pulse Interface power supply common Reverse pulse line Reverse pulse line Normal pulse line Normal pulse line 1 2 3 4 5 7 8 9 10 V+ ALM PF OP SG NP NG PP PG 11 12 13 14 15 16 17 19 20 Shield SD SG CR LSN LSP V5 SON OPC V24 Driver model MR-C10A MR-C20A MR-C10A1 MR-C20A1 Interface power supply common