SMC Corporation of America
Elite Part Number Search
Search Results "VP742R-5DZ1-04-MA-X536"

), 0.5 W DC (21 mA) (3) 24 VDC 1 W DC (83 mA), 0.5 W DC (42 mA) Note (3) 12 VDC 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) Inrush 1.2 VA (12 mA), Holding 1.2 VA (12 mA) 100 VAC Power consumption (Current) 3 position pressure center 2 position double (Metal) Inrush 1.3 VA (11.7 mA), Holding 1.3 VA (11.7 mA) 110 VAC (A) 4 (B) 2 (A) 4 (B) 2 Inrush 2.4 VA (12 mA), Holding 2.4 VA (12 mA) 200 VAC

Ig1 = 20 5 1000 = 0.1 [mA] Ig2 = 20 5 1000 = 0.1 [mA] Ign = 0 (not used) Iga = 0.1 [mA] Igm = 0.1 [mA] Insert these values in equation (11.1). Ig 10 {0.1 + 0 + 0.1 + 1 (0.1 + 0.1)} 4 [mA] According to the result of calculation, use an earth-leakage current breaker having the rated sensitivity current (Ig) of 4.0 mA or more.

When the ambient temperature is out of the range between the temperatures set for AS.04 and AS.06, AL.03 or AL.04 may be generated at the same time when the product is turned ON.

to 85C (with no freezing and condensation) Ambient temperature range NPN open collector: Maximum load current: 80 mA; Internal voltage drop: 1 V or less (with load current of 80 mA); Maximum applied voltage: 30 V; 2 outputs Note 5) Switch output Output specifications PNP open collector: Maximum load current: 80 mA; Internal voltage drop: 1.5 V or less (with load current of 80 mA); 2 outputs

How to Order Sub-plate Assembly Pilot type Nil R External pilot Internal pilot Thread type Plug-in VFR4000 P 04 Nil Rc Non plug-in VFS4000 S 04 G F N NPT NPTF T B Plug-in VFR4000 P 04 Non plug-in VFS4000 S 04 B Piping port (P, A, B port) Note) Bottom ported is not available for external pilot.

or less 50 mA or less Weight 45 g Maximum load current: 80 mA Internal voltage drop: 1 V or less (with load current of 80 mA) Maximum applied voltage: 30 V 2 outputs Resistance Output Note 5) specifications NPN open collector (PF2W300, PF2W330) Switch output Maximum load current: 80 mA Internal voltage drop: 1.5 V or less (with load current of 80 mA) 2 outputs PNP open collector (PF2W301

Ig1 = 20 5 1000 = 0.1 [mA] Ig2 = 20 5 1000 = 0.1 [mA] Ign = 0 (not used) Iga = 0.1 [mA] Igm = 0.1 [mA] Insert these values in equation (11.1). Ig 10 {0.1 + 0 + 0.1 + 1 (0.1 + 0.1)} 4 [mA] According to the result of calculation, use an earth-leakage current breaker having the rated sensitivity current (Ig) of 4.0 mA or more.

14 tube 06 6tube &1 08 ~ 8 tube I ..1 A8 Ma x1 AlO M10 x 1 i~ A14 M14 x 1 I TI>:ead dia/Poi!

In-line In-line In-line Electrical entry direction 3-wire 2-wire Wiring type NPN PNP Output type 24 VDC relay, PLC IC circuit, Relay, PLC Applicable load 5, 12, 24 VDC (4.5 to 28 V) Power supply voltage 10 mA or less Current consumption 28 VDC or less 24 VDC (10 to 28 VDC) Load voltage 2.5 to 40 mA 40 mA or less Load current 4 V or less 0.8 V or less at 10 mA (2 V or less at 40 mA) Internal

Note 6) Lead wire tolerance CD-P12 24 VDC 50 mA CD-P11 100 VAC 25 mA 200 VAC 12.5 mA Part No.

to 40 mA Load current 40 mA or less 0.8 V or less 4 V or less Internal voltage drop 100 A or less at 24 VDC 0.8 mA or less Leakage current Red LED lights when ON.

Contact protection circuit None Internal voltage drop 0.8 V or less 2.4 V or less (to 20 mA)/3 V or less (to 40 mA) Red LED illuminates when ON.

M18 x 1.5 25 to 1800 135 102 19 42 22 18 44 44 3/4 75 192 20 3 156 40 53 145 40 225 19 15 100 80 Rod series Tolerance (mm) B-series rod C-series rod Bore size (mm) Bore size (mm) TDe9 TX E E MM A MA D K G H ZZ MM A MA D K G H ZZ 32 32 34 M16 x 1.5 25 22 18 7 14 55 207 0 0.3 0.040 0.092 0.025 0.064 40 40 40 36 M20 x 1.5 30 27 22.4 9 19 60 212 18 M16 x 1.5 25 22 7 14 55 207 0.025

)-A Y610-(03)-A 04-A 02A VHS40-03A 04A VHS40-06A VHS50-06A 10A Pressure relief 3 port valve 6 VHS20-01A 02A VHS30-02A 03A Attachment 02-A E400-03-A 04-A 06-A Piping adapter 6 E100-M5-A 01-A E200-02-A 03-A 02-A E300-03-A 04-A E500-06-A E600-06-A 10-A 02-A IS10E-4003-A 04-A 06-A Pressure switch with piping adapter 6 01-A IS10E-2002-A 03-A 02-A IS10E-3003-A 04-A Cross spacer 6 Y14-M5-A Y24

When the ambient temperature is out of the range between the temperatures set for AS.04 and AS.06, AL.03 or AL.04 may be generated at the same time when the product is turned ON.

When the ambient temperature is out of the range between the temperatures set for AS.04 and AS.06, AL.03 or AL.04 may be generated at the same time when the product is turned ON.