SMC Corporation of America
Elite Part Number Search
Search Results "VP546-5DZ1-S1-D"

D H1 KNH-R02-100 KNH-R02-150 KNH-R02-200 1 1.5 2 R1/4 14 52 46 D H1 A L1 Reference dimensions after R thread installation Low noise nozzle with male thread: KNS [mm] Connection thread L1 A Width across flats Nozzle size Part no.

Ejector mounting position U D U side D side [Example: When individual wiring type model 45 for SY3000 is selected] ZZY Y3-45-04D-C6J1U 1SET SY3000 manifold model Ejector valve number Note 1) The combined total of solenoid valve and ejector valve stations is a maximum of 20 stations. (Example: When there are 12 solenoid valve stations, there are 8 ejector stations.)

P16 s1 s1 s1 s1 s2 s2 s2 s2 ... ... ... ... s32 s32 s32 s32 0.5mm) 1 2 , 2. 30mm 30mm 3.

4-16 Side entry Top entry Side entry Without cable Without cable Without cable U0 U1 U2 U3 S0 S1 S2 S3 U0 U1 U2 U3 U0 U1 U2 U3 S0 S1 S2 S3 S0 S1 S2 S3 (2) Max. 16 stations (2) Max. 16 stations (2) With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) Max. 16 stations Kit P Kit P Kit J

Model: 5 (VP500), Pilot: Internal Pilot, Pressure Specifications: Nil (Standard (0.7MPa)), Rated Voltage: 5 (24 VDC), Electrical Entry: DZ (DIN terminal with connector, with light/surge voltage suppressor), Safety limit switch/Wiring: S1 (M12 connector, made by Rockwell Automation), Flow Direction: R (right to left), No. of Residual Pressure Exhaust Valves: D (Dual), Soft Start-up: S (with

Model: 5 (VP500), Pilot: Internal Pilot, Pressure Specifications: Nil (Standard (0.7MPa)), Rated Voltage: 5 (24 VDC), Electrical Entry: DZ (DIN terminal with connector, with light/surge voltage suppressor), Safety limit switch/Wiring: M (M12 connector, made by OMRON), Flow Direction: Nil (left to right), No. of Residual Pressure Exhaust Valves: S (Single), Soft Start-up: S (with Soft Start

Model: 5 (VP500), Pilot: Internal Pilot, Pressure Specifications: Nil (Standard (0.7MPa)), Rated Voltage: 5 (24 VDC), Electrical Entry: DZ (DIN terminal with connector, with light/surge voltage suppressor), Safety limit switch/Wiring: M (M12 connector, made by OMRON), Flow Direction: Nil (left to right), No. of Residual Pressure Exhaust Valves: D (Dual), Soft Start-up: S (with Soft Start

Model: 5 (VP500), Pilot: Internal Pilot, Pressure Specifications: Nil (Standard (0.7MPa)), Rated Voltage: 5 (24 VDC), Electrical Entry: DZ (DIN terminal with connector, with light/surge voltage suppressor), Safety limit switch/Wiring: M (M12 connector, made by OMRON), Flow Direction: Nil (left to right), No. of Residual Pressure Exhaust Valves: S (Single)

Model: 5 (VP500), Pilot: Internal Pilot, Pressure Specifications: Nil (Standard (0.7MPa)), Rated Voltage: 5 (24 VDC), Electrical Entry: DZ (DIN terminal with connector, with light/surge voltage suppressor), Safety limit switch/Wiring: M (M12 connector, made by OMRON), Flow Direction: Nil (left to right), No. of Residual Pressure Exhaust Valves: S (Single), Soft Start-up: None, Thread (external

Model: 5 (VP500), Pilot: Internal Pilot, Pressure Specifications: Nil (Standard (0.7MPa)), Rated Voltage: 5 (24 VDC), Electrical Entry: DZ (DIN terminal with connector, with light/surge voltage suppressor), Safety limit switch/Wiring: M (M12 connector, made by OMRON), Flow Direction: Nil (left to right), No. of Residual Pressure Exhaust Valves: S (Single), Soft Start-up: S (with Soft Start

Model: 5 (VP500), Pilot: Internal Pilot, Pressure Specifications: Nil (Standard (0.7MPa)), Rated Voltage: 5 (24 VDC), Electrical Entry: DZ (DIN terminal with connector, with light/surge voltage suppressor), Safety limit switch/Wiring: M (M12 connector, made by OMRON), Flow Direction: R (right to left), No. of Residual Pressure Exhaust Valves: D (Dual), Soft Start-up: S (with Soft Start Function

Model: 5 (VP500), Pilot: Internal Pilot, Pressure Specifications: Nil (Standard (0.7MPa)), Rated Voltage: 5 (24 VDC), Electrical Entry: DZ (DIN terminal with connector, with light/surge voltage suppressor), Safety limit switch/Wiring: M (M12 connector, made by OMRON), Flow Direction: Nil (left to right), No. of Residual Pressure Exhaust Valves: D (Dual), Soft Start-up: S (with Soft Start

LC1-1-S1 PC-98 (MS-DOS) LC1-1-W1 (Windows 95 Japanese) LC1-1-W2 (Windows 95 English) and LC1-1-R (dedicated communication cable) (Refer to pages 80, 81, and 85.)

EXH port P1 LED level meter SUP port Sensor S1 S3 Red ON: Output OFF Green ON: Output ON S2 S4 + P2 Redq Detection port Below set position Large clearance S1, S2: Fix orifice S3: Variable orifice (adjusted by setting dial) S4: Detection nozzle Redw BEST POSITION Set position Greenq In a bridge circuit as in the figure above, a detection gap is applied to the detection nozzle (S4) while the

D-G5P D-K59 D-5NTL D-H7A1 D-H7A2 D-H7B D-H7C D-G59W D-G5PW D-K59W D-G59F D-G79 D-H7PW D-H7BAL D-H7LF D-H7NF D-G5BAL D-H7PW D-H7BW 24VDC 110VAC 220VAC 24VDC 24VDC 110VAC 220VAC 24VDC 110VAC Yes/2 Wire D-B54 Yes/2 Wire D-B53 No/2 Wire D-B64 D-B73 D-C73 D-C73C D-B76 D-C76 D-B80 D-C80 D-C80C Yes/2 Wire Yes/2 Wire 20mA 4~8VDC 50mA 40mA 20mA 24V 48V 110V No/2 Wire ACCESSORIES SWITCH BANDS FOR

Y P E 41 S I D E P O R T E D M A N I F O L D.

D-M9PA(V) D-M9BA(V) 7 13 38 63 D-M9NA(V) 8 14 41 68 Auto switch model 0.5 m (Nil) 1 m (M) 3 m (L) 5 m (Z) Lead wire length Dimensions (mm) D-M9A Indicator light Slotted set screw (flat point) Mounting screw M2.5 x 4 L Stainless steel 2 24 2.8 500(1000)(3000)(5000) 0.2 3 4 6 Most sensitive position 2.6 D-M9NAV/D-M9PAV D-M9BAV 500(1000)(3000)(5000) Mounting screw M2.5 x 4 L Stainless steel