Orifice and Port Size Combinations Class Orifice size (mm) Port size 3 2 4 5 7 10 T Conduit terminal 1/8 (6A) 2 1/4 (8A) 1/4 (8A) 3 3/8 (10A) 1/2 (15A) 1/4 ( 8A) 3/8 (10A) 4 1/2 (15A) Available types of electrical entry are either G, C and T.
Orifice and Port Size Combinations D DIN terminal DL DIN terminal with light DO DIN terminal (without connector) T Conduit terminal TL Conduit terminal with indicator light Class Orifice size (mm) Port size (Note 1) 2 3 4 5 7 10 1/8 (6A) 2 1/4 (8A) 1/4 (8A) 3 3/8 (10A) 1/2 (15A) 1/4 (8A) Connector 3/8 (10A) 4 1/2 (15A) All class B coils come with surge voltage suppressor.
Orifice and Port Size Combinations Class Orifice size (mm) T Conduit terminal (1) Port size 4 2 3 7 5 10 1/8 (6A) 2 1/4 (8A) 1/4 (8A) 3 3/8 (10A) 1/2 (15A) 1/4 (8A) Available types of electrical entry are either G, C and T.
Orifice and Port Size Combinations Orifice size (mm) Class Port size Note) T Conduit terminal TL Conduit terminal with indicator light 2 3 4 5 7 10 D DIN terminal DL DIN terminal with indicator light DO DIN terminal (without connector) 1/8 (6A) 2 1/4 (8A) 1/4 (8A) 3 3/8 (10A) 1/2 (15A) 1/4 (8A) 3/8 (10A) 4 1/2 (15A) 3/4 (20A) Connector Note) 10 is available only for N.C.
Refer to Glossary of Terms on front matter 10 for details on the max. operating pressure differential and the max. system pressure. 3 8 (10A) 6 1.1 26 8 1.6 38 10 0.5 2.2 53 1 2 (15A) 10 2.2 53 Note) Weight of grommet type. Add 60 g for conduit terminal type.
FKM/EPDM O-ring e O-ring e 10A to 25A 15A to 25A Diaphragm assembly Diaphragm assembly Stainless steel, Brass, NBR Stainless steel, Brass, NBR r r Stainless steel, Brass FKM/EPDM 32A to 50A 32A to 50A Valve spring Valve spring Stainless steel Stainless steel, Copper Stainless steel, NBR Stainless steel Class B molded Stainless steel Stainless steel, Silver FKM/EPDM, PTFE t t 10A to
steel, Brass FKM/EPDM O-ring e O-ring e 10A to 25A 15A to 25A Stainless steel, Brass, NBR Stainless steel, Brass, NBR Disk assembly Disk assembly r r Stainless steel, Brass FKM/EPDM 32A to 50A 32A to 50A Valve spring Valve spring Stainless steel Stainless steel, Copper Stainless steel, NBR Stainless steel Class B molded Stainless steel Stainless steel, Silver FKM/EPDM, PTFE t t 10A
(value under the prescribed conditions) 2 1/4 ( 8A) 1/4 ( 8A) VCW (for water) 2 port solenoid valve NBR (FKM) (EPDM) (PTFE) 3 3/8 (10A) Brass (Stainless steel) 1/2 (15A) 1/4 ( 8A) 3/8 (10A) 4 1/2 (15A) 3/4 (20A) Note 1) 10 is N.C. (normally closed) only. OUT OUT IN IN N.C. N.O. 100 Electrical Terminology 1.
-2 VVQZ200-10A-2 VVQZ300-10A-2 This is used when removing the valve for maintenance, or reserving a valve mounting space on the manifold for future use.
-5 VVQZ200-10A-5 VVQZ300-10A-5 This is used when removing the valve for maintenance, or reserving a valve mounting space on the manifold for future use.
SY3000-26-10A 1 set (Blanking plate assembly part no.) SX3140-5MOZ 3 sets (Single solenoid part no.) SX3240-5MOZ 2 sets (Double solenoid part no.) SX3000-23-1A 3 sets (Connector assembly no.) SX3000-23-2A 2 sets (Connector assembly no.)
(value under the prescribed conditions) 2 1/4 ( 8A) 1/4 ( 8A) VCW (for water) 2 port solenoid valve NBR (FKM) (EPDM) (PTFE) 3 3/8 (10A) Brass (Stainless steel) 1/2 (15A) 1/4 ( 8A) 3/8 (10A) 4 1/2 (15A) 3/4 (20A) Note 1) 10 is N.C. (normally closed) only. OUT OUT IN IN N.C. N.O. 100 Electrical Terminology 1.
SY3000-26-10A 1 set (Blanking plate assembly part no.) SX3140-5MOZ 3 sets (Single solenoid part no.) SX3240-5MOZ 2 sets (Double solenoid part no.) SX3000-23-1A 3 sets (Connector assembly no.) SX3000-23-2A 2 sets (Connector assembly no.)
SY3000-26-10A 1 set (Blanking plate assembly part no.) SX3140-5MOZ 3 sets (Single solenoid part no.) SX3240-5MOZ 2 sets (Double solenoid part no.) SX3000-23-1A 3 sets (Connector assembly no.) SX3000-23-2A 2 sets (Connector assembly no.)
VS4310-03 (10A) 3 8 4.2 3.8 0.23 0.32 1.00 0.99 (Closed center) VS4410-01 (6A) 1 8 3.1 3.0 0.28 0.28 0.77 0.75 VS4 360 180 15 or less 45 or less 0.98 1.22 VS4410-02 (8A) 1 4 3.9 3.5 0.22 0.27 0.94 0.84 VS4410-03 (10A) 3 8 4.0 3.7 0.26 0.32 1.00 0.94 (Exhaust center) VQ7 Note 1) Min. operating frequency is once every 30 days.
-03 VX332-03 VX323-03 VX333-03 VX324-03 VX334-03 0.29 0.60 0.82 0.29 0.60 0.7 0.4 0.2 0.7 0.4 0.7 1 0.2 0.3 0.6 0.2 0.3 0.7 1 0.3 0.6 0.2 0.3 1 0.5 0.3 1 0.5 1 1.6 0.3 0.5 0.9 0.25 0.4 1 1.6 0.5 0.9 0.25 0.4 1.5 2.2 3 1.5 1/8 (6A) 380 530 730 380 530 730 530 730 530 730 530 730 530 730 2.2 0.17 0.40 0.64 1/4 (8A) 0.20 0.20 0.82 3 0.27 0.25 1.1 2.0 0.38 0.20 1.6 4 0.17 0.40 0.64 2.2 3/8 (10A
No-fuse breaker Fuse (Note 2) Current Voltage Driver Magnetic contactor Voltage (Note 1) Current Not using power factor improving AC Using power factor improving reactor AC Class [A] [V] reactor LECSB-S5 30A frame 5A 30A frame 5A 10 300V S-N10 LECSB2-S7 30A frame 5A 30A frame 5A 10 240V T LECSB1-S7 30A frame 10A 30A frame 10A 15 LECSB2-S8 30A frame 10A 30A frame 5A 15 Note 1.
Install a Ground Fault Circuit Interrupter(GFCI) to the power supply (sensitivity of leak current 30mA and rated current 10A). (Prepare by yourself) Do not extend the power cable using power strip and so on. That causes decrease of the voltage and the product cannot be operated.
(value under the prescribed conditions) 2 1/4 ( 8A) 1/4 ( 8A) VCW (for water) 2 port solenoid valve NBR (FKM) (EPDM) (PTFE) 3 3/8 (10A) Brass (Stainless steel) 1/2 (15A) 1/4 ( 8A) 3/8 (10A) 4 1/2 (15A) 3/4 (20A) Note 1) 10 is N.C. (normally closed) only. OUT OUT IN IN N.C. N.O. 100 Electrical Terminology 1.
[mm] Model D1 D2 L Weight [g] 8 KQ2C-08A 12.8 9.2 2.6 0.1 10 KQ2C-10A 15.2 11.2 2.7 0.1 12 KQ2C-12A 17.6 13.2 2.7 0.1 16 KQ2C-16A 22.4 17.2 3.2 0.2 Applicable tubing O.D.