[mm] MGPKM, MGPKL Bore size [mm] Standard stroke A B C DA DB E FA FB 50 st or less Over 50 st 100 st or less Over 100 st 100 st or less Over 100 st 100 st or less Over 100 st 50 st or less Over 50 st 100 st or less Over 100 st 12 10, 20, 30, 40, 50 75,100,125,150 36.5 53 75 36.5 39 27.5 30 6 8 0 16.5 36 7 2 16 38 58 86 38 41 28.5 31.5 8 8 0 20 45 7.5 2 20 20, 30, 40, 50, 75, 100 125, 150,
(Sliding bearing) LEYGmL (Ball bushing bearing) [mm] [mm] [mm] [mm] Size Stroke range L DB Size Stroke range L DB 64st or less 51.5 K X 16 90st or less 75 8 91st or more, 100st or less 95 101st or more, 200st or less 105 10 65st or more, 90st or less 74.5 91st or more, 100st or less 95 101st or more, 200st or less 105 16 25 114st or less 91 10 115st or more, 190st or less 115 191st or more
(The noise level rises by approx. 3 dB(A) from the rated condition.)
current: 30 mA Electrical system Cable quantity x Size (Including grounding cable)16 3 cores x 14 AWG (3 cores x 2.0 mm2) Rated operating current (50/60 Hz)17 [A] 2.5/3.0 For Option T1 4.3/4.7 Rated power consumption (50/60 Hz)17 [kW (kVA)] 0.48/0.60 (0.51/0.61) For Option T1 0.73/0.80 (0.85/0.94) Communication function Contact input/output, Serial RS-485/RS-232C Noise level (50/60 Hz)9 [dB
HRL200-W*-40 Approx.35 Installation environment specifications Sound noise: HRL100-A-40 : 75 dB(A) HRL200-A-40 : 75 dB(A) HRL300-A-40 : 71 dB(A) HRL100-W-40 : 72 dB(A) HRL300-W-40 : 72 dB(A) * Front 1m, height 1m, rated condition HRL Series 3.2 Installation 3-7 HRX-OM-X037 Chapter 3 Transport and Setting Up 3.2.3 Installation and maintenance space It is recommended to keep the space around
Valve exhaust noise dampening: 35 dB or more. Collection rate of drainage and oil mist: 99.9% or more Piping work is reduced.
Fieldbus device Operation Manual Master unit Remote unit Local unit Summary of Product Parts Setting (Blue) DA Terminating resistor DA DA Terminating resistor (White) (Yellow) DB DB DB Turn off the power supply while setting the DIP switches. Open the cover and set the DIP switches with a small flat blade screwdriver.
Master unit Remote unit Local unit (Blue) (White) (Yellow) DB DG SLD FG Terminal resister DA Terminal resister DA DA Communication connector for CC-Link DB DG SLD FG DB DG SLD FG CC-Link dedicated cable CC-Link dedicated cable Drawing 2 Connect the terminal resistor between "DA-DB" (Refer to Drawing 3). Terminating resistor Drawing 4 NOTE 1.
Stations: 12 Stations, Option: Built-in Silencer, Direct Exhaust, One-touch Fitting: -, CE Compliant: -
Stations: 4 Stations, Option: Back Pressure Check Valves, Silencer, One-touch Fitting: -, CE Compliant: -
Stations: 6 Stations, Option: Back Pressure Check Valves, Silencer, One-touch Fitting: -, CE Compliant: -
Stations: 7 Stations, Option: -, One-touch Fitting: -, CE Compliant: -
Stations: 12 Stations, Option: Back Pressure Check Valves, External Pilot, One-touch Fitting: -, CE Compliant: -
Stations: 16 Stations, Option: Name Plate, Silencer, One-touch Fitting: -, CE Compliant: -
Stations: 20 Stations, Option: -, One-touch Fitting: -, CE Compliant: -
Stations: 14 Stations, Option: Back Pressure Check Valves, Silencer, One-touch Fitting: -, CE Compliant: -
Stations: 16 Stations, Option: -, One-touch Fitting: -, CE Compliant: -
Stations: 21 Stations, Option: -, One-touch Fitting: -, CE Compliant: -
Stations: 24 Stations, Option: External Pilot, One-touch Fitting: -, CE Compliant: -
Stations: 2 Stations, Option: Built-in Silencer, Direct Exhaust, One-touch Fitting: -, CE Compliant: -