SYJ300, base mount valve manifold, Maximum 20 stations available as standard, M5 ports (41Type); 5/32" NPT or 4 one-touch fittings (42type), Manifold for internal pilot valves, A ports on manifold, MANIFOLD ASSY, VALVE, SS3YJ3 MANIFOLD SYJ300 3/PORT, 1J, SS3YJ3 OTHER SIZE RATING, .52800 lb
SYJ300, base mount valve manifold, Maximum 20 stations available as standard, M5 ports (41Type); 5/32" NPT or 4 one-touch fittings (42type), Manifold for internal pilot valves, A ports on manifold, MANIFOLD ASSY, VALVE, SS3YJ3 MANIFOLD SYJ300 3/PORT, 1J, SS3YJ3 OTHER SIZE RATING, .57200 lb
SYJ300, base mount valve manifold, Maximum 20 stations available as standard, M5 ports (41Type); 5/32" NPT or 4 one-touch fittings (42type), Manifold for internal pilot valves, A ports on manifold, MANIFOLD ASSY, VALVE, SS3YJ3 MANIFOLD SYJ300 3/PORT, 1J, SS3YJ3 OTHER SIZE RATING, .61600 lb
SYJ300, base mount valve manifold, Maximum 20 stations available as standard, M5 ports (41Type); 5/32" NPT or 4 one-touch fittings (42type), Manifold for internal pilot valves, A ports on manifold, MANIFOLD ASSY, VALVE, SS3YJ3 MANIFOLD SYJ300 3/PORT, 1J, SS3YJ3 OTHER SIZE RATING, .66000 lb
SYJ300, base mount valve manifold, Maximum 20 stations available as standard, M5 ports (41Type); 5/32" NPT or 4 one-touch fittings (42type), Manifold for internal pilot valves, A ports on manifold, MANIFOLD ASSY, VALVE, SS3YJ3 MANIFOLD SYJ300 3/PORT, 1J, SS3YJ3 OTHER SIZE RATING, .72600 lb
SYJ300, base mount valve manifold, Maximum 20 stations available as standard, M5 ports (41Type); 5/32" NPT or 4 one-touch fittings (42type), Manifold for internal pilot valves, A ports on manifold, MANIFOLD ASSY, VALVE, SS3YJ3 MANIFOLD SYJ300 3/PORT, 1J, SS3YJ3 OTHER SIZE RATING, .82500 lb
SYJ300, base mount valve manifold, Maximum 20 stations available as standard, M5 ports (41Type); 5/32" NPT or 4 one-touch fittings (42type), Manifold for internal pilot valves, A ports on manifold, MANIFOLD ASSY, VALVE, SS3YJ3 MANIFOLD SYJ300 3/PORT, 1J, SS3YJ3 OTHER SIZE RATING, .85800 lb
SYJ300, base mount valve manifold, Maximum 20 stations available as standard, M5 ports (41Type); 5/32" NPT or 4 one-touch fittings (42type), Manifold for internal pilot valves, A ports on manifold, MANIFOLD ASSY, VALVE, SS3YJ3 MANIFOLD SYJ300 3/PORT, 1J, SS3YJ3 OTHER SIZE RATING, .85800 lb
SYJ300, base mount valve manifold, Maximum 20 stations available as standard, M5 ports (41Type); 5/32" NPT or 4 one-touch fittings (42type), Manifold for internal pilot valves, A ports on manifold, MANIFOLD ASSY, VALVE, SS3YJ3 MANIFOLD SYJ300 3/PORT, 1J, SS3YJ3 OTHER SIZE RATING, .14520 lb
V (mm/s) = Auto switch operation range (mm) Load operating time (ms) x 1000 In cases of high piston speed, the use of an auto switch (D-F5NT, F7NT, G5NT and M5T) with a built-in OFF delay timer (approx. 200ms) makes it possible to extend the load operating time. 4. Wiring should be kept as short as possible.
Piping: 40 (Base Mounted), Stations: 16 Stations, A, B Port: M5T (M5X0.8 NPTF)
Piping: 40R (Base Mounted), Stations: 16 Stations, A, B Port: M5T (M5X0.8 NPTF)
Piping: 41R (Base Mounted), Stations: 16 Stations, A, B Port: M5T (M5X0.8 NPTF)
Stations: 16 Stations, Port Size: M5T (M5X0.8 NPTF), Option: None, CE Compliant: No
Body: 5 (Base Mounted), Stations: 16 Stations, Port Size: M5T (M5X0.8 NPTF)
Piping: 41 (Base Mounted Common SUP Common EXH), Stations: 16 Stations, A B Port Size: M5T (M5X0.8 NPTF)
Manifold Type: 41 (Base Mounted), Valve Stations: 16 Stations, A, B Port: M5T (10-32 Nom)
/F79F D-F7BA/F7BAV 10 3.5 10.5 18 30 42 16 4 10 18.5 30.5 42.5 48.5 72.5 90.5 102.5 D-F7NT 10 8.5 15.5 23 35 47 16 9 15 23.5 35.5 47.5 53.5 77.5 95.5 107.5 D-A7l/A80 10 3 10 10 17.5 29.5 41.5 16 3.5 9.5 9.5 18 30 42 48 72 90 102 D-A79W 10 0.5 7.5 15 27 39 16 1 7 15.5 27.5 39.5 45.5 69.5 87.5 99.5 * In the actual setting, adjust them after confirming the auto switch performance. 457
SY340is for type 41 and 42 manifolds. SY340Ris for type 42 manifolds.
) Note 16) Note 16) Note 16) Note 16) Note 16) Note 8) Pressure can be set higher than the specification pressure in some cases, but use pressure within the specification range.